System functions:
1. The UPH series of laboratory water dispensers has a fully plastic ABS engineering plastic casing, which is resistant to acid and alkali corrosion;
2. Online monitoring of RO pure water conductivity and UP ultra pure water resistivity/water temperature;
3. Equipped with a quantitative water intake setting function (when the water tank is storing water);
4. Equipped with historical data query function;
① Time and amount of water taken each time (year/month/day/hour/minute/liter)
② Previous intake water quality (RO conductivity/UP resistivity)
③ Previous fault records
5. Equipped with a USB interface, historical water intake data can be downloaded to achieve traceability of water samples;
6. Standard Youpu Zui newly designed pure water tank;
7. TOC online display (optional);
8. Pre processing column/ultra purification column monitoring and alarm function (optional).
Technical indicators:
matters needing attention:
1UPH Ultra Pure Water MachineThe water production capacity refers to the rated water production capacity of RO at a water temperature of 25 ℃. For every 1 ℃ decrease in water temperature, the water production of the RO membrane decreases by about 3%. When the water temperature drops below 5 ℃, the RO membrane will stop producing water. When selecting and ordering, users must consider the factor of decreasing winter water temperature in their region;
2. In areas with poor source water quality (TDS>200pm), the RO pure water conductivity of laboratory water treatment machines will increase to over 10 μ s/cm. For users with high water quality requirements, it is recommended to add a water softener and choose the UPR (Type I)+UPHW ordinary combination scheme or the UPR (Type I)+ULPHW high-end combination scheme.
1. The UPH series of laboratory water dispensers has a fully plastic ABS engineering plastic casing, which is resistant to acid and alkali corrosion;
2. Online monitoring of RO pure water conductivity and UP ultra pure water resistivity/water temperature;
3. Equipped with a quantitative water intake setting function (when the water tank is storing water);
4. Equipped with historical data query function;
① Time and amount of water taken each time (year/month/day/hour/minute/liter)
② Previous intake water quality (RO conductivity/UP resistivity)
③ Previous fault records
5. Equipped with a USB interface, historical water intake data can be downloaded to achieve traceability of water samples;
6. Standard Youpu Zui newly designed pure water tank;
7. TOC online display (optional);
8. Pre processing column/ultra purification column monitoring and alarm function (optional).

name | Laboratory water generator UPH | |||
PRODUCT MODEL | UPH-I-5/10/20TN UPH-I-5/10/20NP |
UPH-II-5/10/20TN UPH-II-5/10/20NP |
UPH-III-5/10/20TN UPH-III-5/10/20NP |
UPH-IV-5/10/20TN UPH-IV-5/10/20NP |
Water inlet requirements | Total dissolved solids TDS<200ppm; Water pressure of 0.1~0.4MPa; Water temperature: 5-45 ℃; TOC<100ppb | |||
Water production capacity | 5/10/20 liters/hour | |||
RO effluent quality | ≤ Inlet conductivity × 2% | |||
Up effluent quality | Electrical resistivity 18.2 Ω· cm Particulate matter ≤ 1/ml Microorganisms ≤ 1cfu/ml Heavy metal ions ≤ 20ppb |
Electrical resistivity 18.2 Ω· cm Particulate matter ≤ 1/ml Microorganisms ≤ 1cfu/ml Heavy metal ions ≤ 20ppb Heat source ≤ 0.01EU/ml |
Electrical resistivity 18.2 Ω· cm Particulate matter ≤ 1/ml Microorganisms ≤ 1cfu/ml Heavy metal ions ≤ 10ppb |
Electrical resistivity 18.2 Ω· cm Particulate matter ≤ 1/ml Microorganisms ≤ 1cfu/ml Heavy metal ions ≤ 10ppb Heat source ≤ 0.01EU/ml |
UV UV spectrophotometer | -- | 185/245nm | ||
Host size | 375×500×620(mm) | |||
weight | 30-35kg | |||
Working power supply | AC220V-50HZ (power 30~150W) | |||
scope of application | Atomic Absorption Spectroscopy (AAS) Atomic Emission Spectroscopy (AES) Ion Chromatography (IC) Mass spectrometry analysis (MC) Plasma Emission Spectroscopy (ICP) Gas liquid chromatography analysis (HPLC) |
Gas liquid chromatography analysis (HPLC) Electrophoresis, gel analysis Cell culture of animals and plants |
Used for HPLC IVF、PCR Cell culture of animals and plants Electrochemical Interface Study |
Used for HPLC IVF、PCR、ICP-MS Cell culture of animals and plants Electrochemical Interface Study genetic research test-tube baby |
Water tank configuration | TNP models come standard with a 30L open pure water tank, while TN models come standard with a 15L constant pressure water tank |
matters needing attention:
1UPH Ultra Pure Water MachineThe water production capacity refers to the rated water production capacity of RO at a water temperature of 25 ℃. For every 1 ℃ decrease in water temperature, the water production of the RO membrane decreases by about 3%. When the water temperature drops below 5 ℃, the RO membrane will stop producing water. When selecting and ordering, users must consider the factor of decreasing winter water temperature in their region;
2. In areas with poor source water quality (TDS>200pm), the RO pure water conductivity of laboratory water treatment machines will increase to over 10 μ s/cm. For users with high water quality requirements, it is recommended to add a water softener and choose the UPR (Type I)+UPHW ordinary combination scheme or the UPR (Type I)+ULPHW high-end combination scheme.