DN4 remote transmission liquid turbine flowmeter,The liquid turbine flowmeter is based on the principle of torque balance and belongs to the velocity type flowmeter. Sensors have the characteristics of simple structure, lightweight, high accuracy, good repeatability, sensitive response, and easy installation, maintenance, and use. They can be matched with display instruments with special functions, and can also be used for quantitative control, over limit alarm, etc. They are widely used in industries such as petroleum, chemical, metallurgy, water supply, and papermaking, and are ideal instruments for flow measurement and energy conservation.
DN4 remote transmission liquid turbine flowmeterfeature
- High precision,Generally, it can reach ±1%R, ±0.5%R,High precision type can reach ±0.2%R;
- Good repeatability, short-term repeatability can be achieved0.05%~0.2%,It is precisely because of its good repeatability that it can be obtained through regular calibration or online calibration The accuracy of * is the preferred flowmeter in trade settlement;
- Output pulse frequency signal, suitable for total measurement and computer connection, no zero drift, strong anti-interference ability;
- Original pulse frequency range(10Hz~1.5KHz),Strong signal resolution.
- Wide range ratio, large range ratio can reach1:20;
- Compact and lightweight structure, easy installation and maintenance, and high circulation capacity;
- Suitable for high-voltage measurement, the sensor body does not need to be perforated, making it easy to make into a high-voltage instrument;
- Can be made into an insertion type, suitable for measuring large diameters, with low pressure loss, low price, can be removed without interruption, and easy installation and maintenance.
- Flow meter, orifice flow meter, electromagnetic flow meter,DN4 liquid turbine flowmeterMagnetic flap level gauge, electric contact bimetallic thermometer, explosion-proof electric contact bimetallic thermometer, explosion-proof bimetallic thermometer, bimetallic thermometer with thermocouple/thermal resistance, temperature transmitter, integrated temperature transmitter, universal intelligent temperature transmitter, assembled thermal resistance, local temperature display instrument, armored platinum thermal resistance, explosion-proof thermal resistance, anti-corrosion thermal resistance, end face thermal resistance, socket type thermal resistance, integrated explosion-proof thermal resistance, industrial explosion-proof thermal resistance, assembled thermocouple, explosion-proof thermocouple, thermocouple, industrial assembled thermocouple, pressure transmitter, differential pressure transmitter, pressure transmitter, negative pressure transmitter, micro differential pressure transmitter, remote differential pressure/pressure transmitter, high static pressure differential pressure transmitter, corrosion-resistant Pressure gauge, precision pressure gauge, capsule pressure gauge, rectangular capsule pressure gauge, Electric contact diaphragm pressure gauge, shock resistant electric contact pressure gauge with edge, magnetic assisted electric contact pressure gauge, stainless steel electric contact pressure gauge, double lower limit shock resistant electric contact pressure gauge, electric contact diaphragm pressure gauge, stainless steel diaphragm pressure gauge, precision digital pressure gauge, ground pressure display instrument, remote transmission pressure gauge, stainless steel pressure gauge, all stainless steel diaphragm pressure gauge, edge stainless steel vacuum pressure gauge, shock resistant stainless steel vacuum pressure gauge with edge, diaphragm pressure gauge, electric contact pressure gauge, electric contact vacuum gauge, general pressure gauge, spring tube pressure gauge, oil filled shock resistant pressure gauge, diaphragm pressure gauge, magnetic flap level gauge, (side mounted) flip column control level gauge, (side mounted) flip column remote transmission level gauge Liquid level gauge, (side mounted heat tracing type) flip column liquid level gauge, side mounted magnetic flip plate liquid level gauge, on-site display side mounted flip plate liquid level gauge, floating ball liquid level transmitter, Fabry Perot liquid level transmitter, input type liquid level transmitter, Inductive liquid level transmitter, RF capacitive liquid level transmitter, liquid level display controller, flange ceramic liquid level transmitter, intelligent radar level gauge, screw in ceramic liquid level transmitter, boiler magnetic water level gauge, boiler magnetic remote water level gauge, split electromagnetic flowmeter, sanitary electromagnetic flowmeter, plug-in electromagnetic flowmeter, explosion-proof electromagnetic flowmeter, intelligent vortex flowmeter, intelligent metal tube float flowmeter, temperature and pressure compensation vortex flowmeter, ultrasonic flowmeter, water flow meter, integrated orifice flowmeter, Annubar flowmeter, V-cone flowmeter
Liquid turbine flow meters are classified by function: remote transmission type, integrated display type, low power consumption type, and small quantity type
,Flow meter selection
KHLWG |
Liquid turbine flowmeter |
|
|||||||
Nominal Diameter |
-xxx |
|
50expressDN50 |
||||||
structural form |
- S |
|
intelligent integration |
||||||
W |
|
split-type |
|||||||
Z |
|
plug-in |
|||||||
Range and azimuth |
1 |
|
Standard range |
||||||
2 |
|
Expand range |
|||||||
3 |
|
Special range |
|||||||
precision |
05 |
|
0.5%R |
||||||
10 |
|
1.0%R |
|||||||
25 |
|
2.5%R |
|||||||
50 |
|
5.0%R |
|||||||
T |
|
Special precision standards |
|||||||
Temperature and pressure resistance |
A |
|
room temperature and pressure |
||||||
B |
|
Special temperature and pressure |
|||||||
communication protocol |
1 |
|
No communication interface |
||||||
2 |
|
Hartagreement |
|||||||
3 |
|
MODBUS |
|||||||
Integrated signal output |
0 |
|
none |
||||||
1 |
|
three-wire system4-20mA |
|||||||
2 |
|
three-wire system0-20mA |
|||||||
3 |
|
two-wire system4-20mA |
|||||||
4 |
|
pulse output |
|||||||
power supply method |
1 |
|
DC24v |
||||||
2 |
|
battery-powered |
|||||||
explosion-proof |
N |
|
non-explosion-proof |
||||||
Ex |
|
ExllBT6 |
|||||||
When placing an order, it is necessary toProvide the inner and outer diameters of the pipeline, as well as the material and medium of the pipeline