LSOH
Zero halogen low smoke flame-retardant wire and cable product models: WDZ-BY, YWDZ-BY, JWDZ-BYJY, WDZ-BLYJY, WDZ-BYJYB, WDZ-BLYJYB
Product details

Halogen free, low smoke, flame-retardant wire and cable

Product models: WDZ-BY, YWDZ-BY, JWDZ-BYJY, WDZ-BLYJY, WDZ-BYJYB, WDZ-BLYJYB.
Conductor cross-section: 2-61
Product Introduction:
Standard for halogen-free low smoke flame-retardant cable products: Refer to standards such as GB/T12706 and GB9330.
1. Application of halogen-free low smoke flame-retardant cable:
Low smoke and flame-retardant halogen-free cables are suitable for fixed installation on AC 50Hz transmission and distribution lines with voltage levels of 1kV and below for the purpose of transmitting electrical energy; Halogen free low smoke flame-retardant cables are mainly used in power plants, petrochemicals, steel plants, tunnels, papermaking, substations, and electronic computer centers with high flame retardant requirements.
2: Characteristics of halogen-free, low smoke, flame-retardant power cables:
(1) Release of halogen-free acid gas.
(2) Smoke less.
(3) Less corrosive gas is generated.
(4) Good flame retardant performance.
3. Specification range:
(1) The specifications of halogen-free low smoke flame-retardant cross-linked polyethylene insulated power cables comply with<35kV and below cross-linked polyethylene insulated power cables.
(2) The specifications of halogen-free low smoke flame-retardant control cables comply with the requirements of cross-linked ethylene insulated and polyvinyl chloride sheathed control cables.
4. Main technical performance of halogen-free low smoke flame-retardant cable:
(1) The flame retardant performance of the finished cable meets the requirements of IEC60332-3 standard.
(2) Index of halogen-free low smoke materials:
a、 The amount of halogen acid gas emitted (mg/g) is 0.
b. PH value ≥ 4.3.
c、 Conductivity μ s ≤ 10.
d、 Toxicity index ≤ 5.
(3) The oxygen index of halogen-free low smoke flame retardant materials shall not be less than 30.
(4) The finished cable shall have a light transmittance of not less than 60% as measured according to the IEC1034 standard.
Halogen-free low smoke flame-retardant cable model
Model name
WDZ-BY copper core halogen-free low smoke flame-retardant polyolefin insulated wire
WDZ-BL aluminum core halogen-free low smoke flame-retardant polyolefin insulated wire
YWDZ-BY copper core cross-linked polyethylene halogen-free low smoke flame-retardant polyolefin insulated wire
YWDZ-BLY aluminum core cross-linked polyethylene halogen-free low smoke flame-retardant polyolefin insulated wire
JWDZ-BYJY Copper Core Cross linked Polyethylene Insulated Halogen Free Low Smoke Flame Retardant Polyolefin Sheath Cable
WDZ-BLYJY aluminum core cross-linked polyethylene insulated halogen-free low smoke flame-retardant polyolefin sheathed cable
WDZ-BYJYB copper core cross-linked polyethylene insulated halogen-free low smoke flame-retardant polyolefin sheathed flat cable
WDZ-BLYJYB aluminum core cross-linked polyethylene insulated halogen-free low smoke flame-retardant polyolefin sheathed flat cable