Product Overview Product overview
The LPT-23 series sanitary pressure transmitter is a rod-shaped structure pressure transmitter. Unlike conventional pressure transmitters, the pressure sensing diaphragm is a flat diaphragm, which is hygienic, has no dead corners, and is easy to blow and clean. At the same time, different anti-corrosion diaphragms can be used to deal with corrosion in corrosive media conditions. Small in size, suitable for integration on devices, and can be densely installed. The interior is sealed with soft solid adhesive, which has better anti vibration effect. The product supports MODBUS protocol and reserves interfaces for further development of supporting equipment, which can assist in extending the functions of supporting equipment and optimizing the system. Suitable for industries such as food, medicine, hygiene, and brewing.
performance metrics TECHNICAL PARAMETERS
Power supply: 12~32VDC;
Measurement medium: oil, water, gas;
Measurement range: Negative pressure type: -0.1~0Mpa; Micro pressure type: 0-2KPa; Positive pressure type: 0-60Mpa; (Higher requirements can be customized)
Measurement accuracy: 0.25% FS; (higher accuracy can be customized)
Overload capacity: 2 times full load pressure:
Output signal: two-wire 4-20mA; three wire voltage output: 0-5V, 1-5V, 0-10V;
Communication mode: 4-20mA; RS485;
Load capacity: current type ≤ 500 Ω, voltage type ≥ 250K Ω;
Threaded interface: M20 * 1.5/G1/2/clamp connection/flange connection (can be customized on site);
Electrical interface: Husman waterproof outlet hole, including locking wire busbar; M12 aviation plug interface
Temperature drift coefficient: Within the specified working temperature, for every 10 ℃ change in ambient temperature, the output change is ≤ ± 0.05% of the range, and the annual drift is < ± 0.3%
Long term stability: ± 0.1% FS/year;
Shell material: die cast aluminum, epoxy resin coating, with sealing gasket
Shell protection: IP65
Explosion proof rating: Exd IIC T6Gb;
Working temperature: -20~85 ℃
Storage temperature: -40~100 ℃
Relative humidity: 0-95% RH
Overall dimensions APPEARANCE OF SIZE
The materials are being prepared ..
Installation requirements INSTALLATION
The materials are being prepared ..