LGF series standard differential square wave output probe 542-612542-613
LGF linear micrometer
542 Series - Economical Design
characteristic:
1. The design of the guide part of the measuring rod should have good anti vibration and anti collision effects.
2. Good sliding durability can be used for at least 15 million cycles (internal testing).
3. Maximum allowable acceleration value for vibration and collision prevention: 100G( 11ms ) ( IEC60068-2-27 )
4. LGF-Z series, with origin markings on the linear encoder and a resolution of 0.1 μ m
Technical parameters:
Accuracy: Refer to performance parameters (excluding quantization bias)
resolving power: 5μm, 1 μ m or 0.5 μ m
Length benchmark: photoelectric linear encoder
Zui * High reaction speed: 1500mm/s
Measuring needle: ø 3mm hard alloy
axle sleeve: ø 8mm or ø 15mm
Bearing type: Linear ball bearing
Force measurement: refer to performance parameters
Output signal: 90 degree phase difference, differential square wave (RS-422A equivalent)
Signal spacing: 20μm ( 542-612, 542-613 ) ,
4μm ( 542-161, 542-162, 542-163 ) ,
2μm ( 542-171, 542-172, 542-173 )
Dust/water protection level: up to IP66 protection standard
Standard attachments
538610: Measuring head with wrench (for measuring models with a range of 10mm)
210187: Measuring head with wrench (for measuring range of 25/50mm models)
Performance parameters:
Item number |
542-171 |
542-161 |
542-172 |
542-162 |
542-612 |
542-173 |
542-163 |
542-613 |
|
measuring range |
10mm |
25mm |
50mm |
||||||
Resolution |
0.5µm |
1µm |
0.5µm |
1µm |
5µm |
0.5µm |
1µm |
5µm |
|
Measurement accuracy (20 º C) L=arbitrary measurement length (mm) |
( 1.5+L/50 ) µm |
(7.5+L/50 ) µm |
( 1.5+L/50 ) µm |
(7.5+L/50)µm |
|||||
Quantitative bias |
±1 |
||||||||
Force measurement |
The measuring rod is facing upwards |
Below 1.0N |
Below 4.0N |
Below 4.9N |
|||||
Horizontal measuring rod |
Below 1.1N |
Below 4.3N |
Below 5.3N |
||||||
The measuring rod is facing downwards |
Below 1.2N |
Below 4.6N |
Below 5.7N |
||||||
Length benchmark |
Photoelectric linear encoder |
||||||||
Response speed * 1 |
1500mm/s |
||||||||
output |
90 º phase difference, differential square wave (equivalent to RS-422A), Zui small edge spacing: 1000ns is used for the 5 µ m type, 500ns for 1 µ m, 250ns for 0.5 µ m |
||||||||
Output square wave spacing |
2µm |
4µm |
2µm |
4µm |
20µm |
2µm |
4µm |
20µm |
|
weight |
About 260g |
About 300g |
About 400g |
||||||
Dust/water protection level * 2 |
Achieve IP66 protection level (only for micrometer) |
||||||||
Measuring head |
ø 3mm hard alloy (fixing screw: M2.5 (P=0.45) × 5), standard probe No.901312 |
||||||||
Clamp sleeve |
ø8mm |
ø15mm |
|||||||
Bearing type |
Linear ball bearing |
||||||||
Output cable length |
2m (directly from the casing) |
||||||||
Connector |
Plug: RM12BPE-6PH (HIROSE), compatible with sockets: RM12BRD-6S ( HIROSE) |
||||||||
Operating temperature (humidity) range |
0-40 º C (RH 20-80%, no condensation) |
||||||||
Storage temperature (humidity) range |
-10-60 º C (RH 20-80%, no condensation) |
||||||||
Standard attachments |
Special wrench for measuring head: No.538610 |
Special wrench for measuring head: No.210187 |
Sanfeng Mitutoyo linear micrometer, all models:
542-156, 542-157, 542-158
LGF linear micrometer
542-171/ 542-161/ 542-172/ 542-162/ 542-612/ 542-173/ 542-163/542-613
LGF linear micrometer
542-174/542-164/542-175/542-165/542-176/542-166
LGB linear micrometer
542-204/542-222/542-222H/542-401/542-224/542-230/542-223/542-244/542-262/542-262H/542-421/542-264/542-270
LGD linear micrometer
575-326/575-327/575-328
575-336/575-337/575-338
LGS linear micrometer
575-303/575-313
Laser Holographic Micrometer
542-711-1/542-712-1
LGB linear micrometer
542-246
LGF linear micrometer
542-181/542-182
Laser Holographic Micrometer
542-925/542-926
Long range linear micrometer
542-312/542-316/542-314/542-332/542-336/542-334
542-313/542-315/542-333/542-335