Product Application
Heating device
■ Conveyor system
■ HVAC equipment
Construction Machinery
Industries such as electricity, metallurgy, glass, chemical, rubber, and textile
Technical data
| insulation resistance | When the ambient temperature is within the range of (15-35) ℃; |
| When the relative humidity is less than 80% | |
| The insulation resistance value of platinum resistance should be greater than 100M Ω | |
| Self heating effect | Thermal resistance allows a maximum measured current of 2-5mA; the resulting temperature rise is not greater than 0.3 ℃ |
| Extension tube | Stainless steel, length 50mm |
| Minimum depth of placement | ≥50mm, Excluding special products |
| process connection | Stainless steel, threaded |
| Protection tube | Stainless steel, 4mm, 6mm, 8mm |
| response time | t0.5,10s~120s |
| accuracy class | Pt100, Class A: ± (0.15+0.002 | t |) |
| Grade B: ± (0.30+0.005 | t |) | |
| | t | "is the absolute value of the measured temperature of the temperature sensing element | |
| Junction box | Cast aluminum casing, outlet thread M16 * 1.5, IP65 |
| wiring method | Two wire system, three wire system, four wire system |
Instructions
·PL7102If dual support is required, it is only available for two-wire system selection;
·Protective tube and process connection material come standard with stainless steel1.4301, itsHe is made of stainless steel material. Please consult our sales staff and select the appropriate materialIndicate;
·Special range or selection of other temperature sensing components such as:Pt500,Pt1000Wait, please consult our sales staff and indicate when selecting;
·When choosing a module with a temperature transmitter, please consult our salespersonMember.