1、 Product functions and features
Multi battery measurement
frequency
Phase current, average phase current(RMS)
Phase voltage, average phase voltage(RMS)
Line voltage, average line voltage(RMS)
Active power of each phase and total active power
Reactive power of each phase and total reactive power
Apparent power of each phase and total apparent power
Power factor and average power factor of each phase
Energy Measurement
Measure four quadrant electrical energy, no loss in case of power failure.
Positive active energy
Responsible for generating electrical energy
Positive and reactive electrical energy
Negative reactive energy
data collection
adoptRS485Digital communication interface collects all data and supportsMODBUSspecification
Provide a demonstration program for the upper computer to facilitate users in writing upper computer programs.
monitor
have4aLEDIndicator lights monitor the working status: running/electric energy pulse/Communication sending/Communication reception.
2、 Technical indicators
Reference standardsGB/T13850-1998 IEC688:1992 DL/T721-2000 IEC61000-4
Accuracy: Phase voltage, current, power<0.5%RD
Electric energy and line voltage are less than1.0%RD
Frequency ≤0.1%RD
Input range voltage5~120V/600V(maximum600V)
current0~1A/5A(maximum6A)
Absorption power consumption: Each voltage channel is less than0.4VA(347V)/0.2VA(150V)
Each current<0.1VA(5A)
Overload energy voltage750Vcontinuous/1000V 10second/1200V 3second
current2Multiple rated continuous/10Double rated30second
Measurement system wiring method: three-phase four wire/three-phase three-wire/One phase two line or one phase three line, etc
Programmable programming mode(password)
Choose three-phase four wire measurement system/three-phase three-wire/One phase, two lines/One phase, three lines, etc
CT,PTtransformation ratio 1~10000
Display content page change time/Screen Selection
Communication baud rate:1200/2400/4800/9600/19200
Odd/even/no checksum
address 1~255
Electric energy accumulation reset(password)
Communication serial portRS485(standard)/RS232(optional)
Communication ProtocolMODBUS-RTU
Insulation strength object in input/output/Between power sources
Test MethodAC2kV1Minute leakage current2mA
Electromagnetic compatibility surge power supply:4kV(1.2×50μs) I/OLine:2kV
Fast transient pulse train power supply:4kV,2.5kHz I/OLine:2kV, 5kHz
Electrostatic discharge contact discharge:6kV Air gap discharge:8kV
radio-frequency electromagnetic field10V/mModerate intensity electromagnetic radiation(If the distance is not less than1Mi's handheld walkie talkie)
Working condition temperature -10~+50℃
humidity 20~95%(No condensation)
Working power supply voltageAC85~265V 50/60Hz DC85~330V(standard)
AC30~60V 50/60Hz DC18~90V(optional)
Whole machine power consumption<4W
External dimensions External dimensions110mm×75mm×71mm
Installation methodDINGuide rail(35 mm)Or fixed with screws