Industrial amplifier WGA-680A
The signal amplifier WGA-680A supports CC Link (optional) with a sampling frequency of 4000 times/second and a resolution of 24 bits. It has high-perf
Product details

signal amplifier WGA-680A

Summary

● Supports CC Link (optional)
High performance processing with a sampling frequency of 4000 times per second and a resolution of 24 bits
● Rich comparison functions (upper limit, upper limit, OK, lower limit, lower limit)
The standard equipment has a simulated (D-A) output of 4000 times per second
Display range: -99999 to 99999

------------------------------------------------------------------------------------------------------

feature

WGA-680A is an amplifier used for measuring physical quantities such as load, which can be assembled with strain gauge sensors to perform high-frequency sampling and display load.

Product Overview

Model Name

WGA-680A-00 No optional accessories available
WGA-680A-01 BCD/TEDS
WGA-680A-02 RS-232C/TEDS
WGA-680A-03 RS-485/TEDS
WGA-680A-04 CC-Link
WGA-680A-10 No optional accessories available
WGA-680A-11 BCD/TEDS
WGA-680A-12 RS-232C/TEDS
WGA-680A-13 RS-485/TEDS
WGA-680A-14 CC-Link

Specifications

Number of measurement channels 1
Applicable sensors Strain gauge sensor (4-wire type)
Applicable bridge resistors 87.5Ω~1kΩ
(Up to 4 350 Ω sensors can be connected in parallel)

category

power supply voltage You can choose DC2V or 10V

Specifications

measurement range -3.2mV/V to 3.2mV/V (including zero adjustment range)
Zero adjustment range Within the measurement range (non holding when power is cut off)
nonlinear ± (0.02% FS+1 digit) or less
stability Zero point: ± 0.25 μ mRTI/℃ or below
Sensitivity: ± 0.01%/℃ or below
calibration function Actual load calibration, sensitivity registration calibration, numerical registration calibration
Smooth function Filter: 10Hz, 30Hz, 100Hz, 300Hz
Attenuation characteristics: -12dB/oct
Average movement: 0, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048 times Minimum scale: 1, 2, 5, 10, 20, 50, 100, 200, 500, 100, 200, 1000
Zero correction function Zero tracking function (automatic digital zeroing within the set range)
Zero function near zero (displayed as zero when within the set range of 0-9)
Addition function Set range ± 99999
Original value display function -3.2000mV/V~3.2000mV/V (5位)
Accuracy: ± 0.1% FS or below
Upper and lower limit comparison function Set points: 4 points
Mode: There are 4 sets of mode files (comparison values) for login, and the types can be switched through function settings: upper limit (HH), upper limit (HI), OK, lower limit (LO), lower limit (LL). Setting range: ± 99999
Lag: 0~99999
Comparison function: normal time/hold time
Upper and lower limit configuration: Configure the upper or lower limits of each comparator
Maintain functionality Digital peak/valley value maintenance
(No simulated peak/valley value retention function)
category
Any point hold, peak hold, valley hold, peak to peak hold, interval specified peak hold, time specified peak hold
Interval specified valley value maintenance, time specified valley value maintenance
Interval specified peak to peak hold, time specified peak to peak hold delay time 0.00~9.99 seconds
Detection time: 0.01 to 9.99 seconds
display Display range: ± 99999 (decimal point position can be set arbitrarily) Refresh speed: 0.12, 0.24, 0.49, 0.98, 1.95, 3.90, 7.80, 15.6 times/second (in normal display mode) Display mode: normal, hold
Comparative judgment: 5 points (HH, HI, OK, LO, LL)
Setting content: 2 points (HOLD, LOCK)
controlled output Points: 5 points
Types: HH, HI, OK, LO, LL
Output form: Open collector DC30V, 20mA max
control input Points: 3 points
Types: Zero instruction, Hold instruction, Reset instruction
Signal mode: no voltage contact signal or open collector signal (when applying a DC 12V voltage, passing a current of 5mA)
power supply AC power specification AC100V~240V 50/60Hz Consumption current: 20VA or below
DC power specification DC10V~30V 50/60Hz Consumption current: 10W or less
Overall dimensions 96mm (W) × 96mm (H) × 126mm (D) (excluding protruding parts)
weight About 750g (excluding optional accessories)
Temperature and humidity range for use -10-50 ℃, 20-80% RH (no condensation)
Applicable specifications
EMC Directive EN61326-1 (Class A)
Low voltage command EN61010-1,EN61010-2-030
(Set Type II, Pollution Level 2, Measurement Type O (Other))
RoHS Directive EN50581
Standard Accessories User Manual (CD)
Unit stickers
Control input/output terminal block/connection cable with a straight screwdriver
Choose accessories AC100V power cable: P-23
AC200V power cable: P-28
6-core input cable for NDK connector: U-29~32
4-core input cable for NDK connector: U-33-36

Choose product specifications

BCD data output
output 20 bit data (4 bits x 5 bits)
Negative sign, OVER, EOC (End of Conversion), Maintain interval output, Detect interval output
Output form: open collector DC30V, 20mA max
input Points: 2 points (keep input/output, disable input)
Input form: no voltage contact signal or open collector signal
(Can apply a voltage of DC12V and pass a current of 5mA)
Output frequency About 15.6 times/second, about 31.3 times/second, about 62.5 times/second, about 125 times/second
Output logic Data logic: positive logic, negative logic
EOC logic: positive logic, negative logic
Symbolic Logic: Positive Logic, Negative Logic
RS-232C
Signal mode RS-232C dual mode
transmission method Synchronous adjustment type
Communication speed 2400,4800,9600,19200bps
Position composition Data bit: 7
Stop position: 1
Parity: Odd
flow control none
RS-485
Signal mode RS-485 dual mode
Communication speed 2400,4800,9600,19200bp
Position composition Data bit: 7
Stop position: 1
Parity: Odd
flow control none
Device ID 1~99
CC-Link
version Ver.1.10
Station type Remote control equipment station
Number of occupied stations 1 station, 2 stations, 4 stations
connecting cable 10Mbps,5Mbps,2.5Mbps,625kbps,156kbps
transmission speed 1 to 64 stations
Station number Cable corresponding to CC Link Ver.1.10
(3-core twisted pair cable with shielded wire)
TEDS Corresponding
Suitable for sensors Sensor with IEEE template No.33 information
(Cable length of 30m or more)
interface 对应 IEEE1451.4 Mixed Mode Transducer Interface Class2
calibration function Read TEDS data and automatically register sensitivity