Inductive pressure transmitter
The YSG series inductive pressure (micro pressure) transmitter consists of a mechanical pressure gauge and an electronic amplifier. It directly indica
Product details
Product Description:
The YSG series inductive pressure (micro pressure) transmitter consists of a mechanical pressure gauge and an electronic amplifier. It not only directly indicates the pressure value through a pointer for on-site detection and calibration, but also converts the measured pressure value into a standard DC signal of DC 0-10mA or DC 4-20mA for long-distance transmission.
Instruments have the advantages of intuitiveness, good stability, and small temperature drift. They can be used for measuring the pressure (micro pressure) or negative pressure of liquid or vapor media in various industrial processes and measurement systems, as well as signal transmission, to achieve automatic detection and control of production processes.
Technical Specifications:
Model: Specification Accuracy Class 1.5 ± 1.5%
YSG-2/3 A is an inductive ammonia pressure transmitter
Working conditions:
Suitable for ambient temperatures ranging from -10 to 55 ℃;
The relative humidity of the air is ≤ 85%;
When the ambient temperature deviates by 20 ± 5 ℃, the instrument indication error should be calculated according to the following formula:
Δ≤±(δ+KΔt);
δ - allowable basic error value%;
Δt-/t2-t1/C;
t2-Any value of ambient temperature;
t1-When t2 is above 25 ℃, it is 25 ℃, and when it is below 15 ℃, it is 15 ℃;
K-Instrument temperature additional error level 1.5, table K=0.075%/℃
The YSG series inductive pressure (micro pressure) transmitter consists of a mechanical pressure gauge and an electronic amplifier. It not only directly indicates the pressure value through a pointer for on-site detection and calibration, but also converts the measured pressure value into a standard DC signal of DC 0-10mA or DC 4-20mA for long-distance transmission.
Instruments have the advantages of intuitiveness, good stability, and small temperature drift. They can be used for measuring the pressure (micro pressure) or negative pressure of liquid or vapor media in various industrial processes and measurement systems, as well as signal transmission, to achieve automatic detection and control of production processes.
Technical Specifications:
Model: Specification Accuracy Class 1.5 ± 1.5%
YSG-2/3 A is an inductive ammonia pressure transmitter
|
Model number And its name |
YSG-3Inductive pressure transmitter YSG-03Inductive pressure transmitter |
YSG-2Inductive pressure transmitter YSG-02Inductive micro pressure transmitter |
| Working Voltage | DC 24V | DC 220V |
| output signal | DC 4-20mA | DC 0~10mA |
| load resistor | ≤250Ω | ≤1KΩ |
|
terminal block |
① ② Two line system+output - |
① ② ③ ④ ⑤ + - 220V 〨 Output communication location |
| Weight kg | 1.0 | 1.3 |
| Supporting facilities Secondary instrument |
XMY-30 pressure digital display instrument XMY-32 pressure digital controller |
XMY-20 pressure digital display instrument XMY-22 pressure digital controller |
| model | Mpa | Pa |
|
measure quantity Fan enclose |
0~0.06 0~0.1 -0.1~0 0~0.16 -0.1~0.06 0~0.25 -0.1~0.15 0~0.4 -0.1~0.3 0~0.6 -0.1~0.5 0~1 -0.1~0.9 0~1.6 -0.1~1.5 0~2.5 -0.1~2.4 0~4 0~6 0~10 0~16 0~25 0~40 0~60 |
0~250 -250~0 -120~+120 0~400 -400~0 -200~+200 0~600 -600~0 -300~+300 0~1000 -1000~0 -500~+500 0~1600 -1600~0 -800~+800 0~2500 -2500~0 -1200~+1200 0~4000 -4000~0 -2000~+2000 0~6000 -6000~0 -3000~+3000 0~10000 -10000~0 -5000~+5000 0~16000 -16000~0 -8000~+8000 0~25000 -25000~0 -12000~+12000 0~40000 -40000~0 -20000~+20000 |
Working conditions:
Suitable for ambient temperatures ranging from -10 to 55 ℃;
The relative humidity of the air is ≤ 85%;
When the ambient temperature deviates by 20 ± 5 ℃, the instrument indication error should be calculated according to the following formula:
Δ≤±(δ+KΔt);
δ - allowable basic error value%;
Δt-/t2-t1/C;
t2-Any value of ambient temperature;
t1-When t2 is above 25 ℃, it is 25 ℃, and when it is below 15 ℃, it is 15 ℃;
K-Instrument temperature additional error level 1.5, table K=0.075%/℃