English

Shanghai Zengjun Industrial Co., Ltd
Home>Products>Inductance measuring instrument AT776
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    Room 1006, Building 10, Baosheng International Wealth Center, No. 18 Baosheng Road, Songjiang District, Shanghai
Contact Now
Inductance measuring instrument AT776
Introduction to inductance measuring instrument AT776: The inductance measuring instrument AT776 has a built-in testing frequency of 50Hz~100kHz and p
Product details

Introduction to inductance measuring instrument AT776:


Inductance measuring instrument AT776Built in 50Hz~100kHz testing frequency, and provides 0.1V, 0.3V, and 1V testing levels to fully meet the needs of most production sites and experimental situations.
Built in RS232C interface, compatible with SCPI programming language, easy to communicate with computers and complete all instrument functions.
Built in Handler interface, combined with RS232C interface to complete complex automatic control systems.

Performance characteristics of inductance measuring instrument AT776
High brightness, ultra clear four-color VFD display.
The third window can display ESR, EPR, Δ ABS, Δ% or sorting results simultaneously.
● comparator (sorting) function: Built in 20 sets of sorting records, P1, P2, P3, NG, AUX sorting and HI, IN, LO, AUX sorting.
Custom sorting result sound and volume.
The display brightness is adjustable.
application
● Inductance measurement
● Equivalent resistance measurement

Technical parameters of inductance measuring instrument AT776:

measurement parameters L-Q, L-ESR,L-EPR,R-Q
Basic accuracy 0.05%
test frequency 50Hz,60Hz,100Hz,120Hz,1kHz,10kHz,20kHz,40kHz,50kHz,100kHz
display range L: 0.0001μH - 99999H ESR,EPR: 0.0001Ω - 99.999MΩ Q: 0.0001 - 99999 Δ%:-99999% - 99999%
output impedance 30 Ω, 50 Ω, and 100 Ω
range Automatic and manual 9-range
signal level 0.1Vrms, 0.3Vrms, and 1Vrms
test speed 15 times/second, 5 times/second, 2 times/second
equivalent circuit series and parallel
correction Open circuit point frequency or sweep frequency reset, short circuit point frequency or sweep frequency reset
comparator 20 sets of records, 5 levels of sorting, sound
interface RS232C interface Handler interface
Power requirements Voltage: 198VAC~240VAC Frequency: 50Hz Power: Maximum 15VA
Dimensions and Weight Outer dimensions (mm): 264 (width) x107 (height) x350 (depth) Inner dimensions: 216 (width) x88 (height) x323 (depth) Weight: 4kg
attachment ATL501: Test Cable ATL607: Test Fixture ATL600: Short Circuit Piece
other VFD four-color high-definition color screen, keyboard lock and data retention function
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!