INDUSTRIAL-SCIENTIFIC, USA
INDUSTRIAL-SCIENTIFIC GTD-5100F Pump Suction VOC Gas Detector Product Introduction:
Product model: GTD-5100F
Product brand: Industrial Scientific, USA
Product category: VOC gas detector
Product note: VOC gas detector
INDUSTRIAL-SCIENTIFIC GTD-5100F Pump Suction VOC Gas Detector Product Overview:
◤ Adopting flame-retardant structure, continuously detecting VOC gases in explosive hazardous areas
Adopting a built-in microprocessor to achieve self diagnostic function
Adopting integrated modular sensors to improve maintenance convenience
◤ Built in digital flow sensor, adjustable gas flow rate
Adopting a built-in sampling pump to achieve rapid gas leakage response
Using PID sensors to detect low concentration VOC gases
Using a magnetic rod to achieve non open calibration and program settings
4-digit concentration display and digital flow display
4-20mA DC output signal
RS-485 Modbus (independent) serial communication is easy to build monitoring systems
3-wire system
Level 2 alarm, single fault display, and relay contact output
Single person calibration and maintenance
INDUSTRIAL-SCIENTIFIC GTD-5100F Pump Suction VOC Gas Detector Product Parameters:
| model | GTD-5100F VOC |
| Measuring gases | VOC gases (benzene, toluene, xylene, etc.) |
| measurement method | pump-suction type |
| measurement method | Photoionization detector (PID) |
| range | 0-9999 adjustable |
| response time | T90<5 seconds |
| precision | ± 3%/full scale |
| Operation method | Magnetic rod operation |
| Work mode display | Alarm/fault LED display, flow rate |
| Indication display | FND display (4-digit) |
| Alarm signal output | 250V 1A/3-stage single pole single throw switch (SPST) relay contacts (2-level alarm, 1-fault) |
| output signal | Analog output: 4-20mA DC |
| Digital output: RS-485 Modbus (optional) | |
| sampling method | Diaphragm sampling pump |
| Sampling pipeline | Outer diameter: 1/4 inch (standard) |
| traffic | Maximum: 0~1000ml/min |
| Cable/Distance | Power cable+signal cable: 3-wire>1.5 square (AWG16) |
| 4-20mA DC signal: 2500m | |
| RS-485 Modbus signal: 1000m | |
| PoE (Power over Ethernet): up to 100m | |
| Pipe connection | G. R (Rc). NPT 1/2 inch and 3/4 inch (G 3/4 inch: standard) |
| Installation Type | wall-mounted installation |
| Operating Temperature | -40℃ ~ +60 ℃ |
| Operating humidity | 5-99% RH (non condensing) |
| operating power | Standard: 18-31V DC (conventional: 24V DC)/280mA |
| material | aluminum die casting |
| size | 195 (width) x 139 (height) x 154 (depth) mm |
| weight | 4kg |
| certification | Explosion proof (Ex d IIC T6, IP65) KCs, CE |