IH type chemical centrifugal pump
IH type chemical centrifugal pump is a single-stage single suction (axial suction) cantilever centrifugal pump used for conveying liquids that do not
Product details

  

Introduction:IH type chemical centrifugal pump is a single-stage single suction (axial suction) cantilever centrifugal pump used for conveying liquids that do not contain solid particles and have corrosiveness and viscosity similar to water. Its marking, rated performance, and size are equivalent to the international standard ISO2858, which has the characteristics of wide performance range, high efficiency, high level of "three modernizations", and easy maintenance. Its efficiency is on average 5% higher than that of F-type pumps, and it is an energy-saving product promoted by the country.

The components of IH type chemical centrifugal pumps that come into contact with the medium are commonly made of materials such as 0Cr18Ni9, 0Cr18Ni9, 0Cr18Ni9Ti, 1Cr18Ni12Mo2Ti, 40Cr, Monel, 1Cr18Ni12Mo2Ti, Ti (titanium), 00Cr17Ni12Mo2Ti, Hastelloy B alloy, 0Cr25Ni20, F5 series alloy, 20 alloy steel, 0Cr25Ni6Mo3Cu2Mn2Si, etc. The shaft seal adopts mechanical seal, power seal, and packing seal, and users can choose according to actual working conditions.

Application:Suitable for industries such as chemical, petroleum, metallurgy, power, papermaking, food, pharmaceuticals, environmental protection, wastewater treatment, and synthetic fibers for transporting various corrosive or non polluting media similar to water.

Performance range:Flow rate Q: 0.3~400m3/h

Head H 5-125m

Imported diameter DN 32~200mm

Working pressure~1.6MPa

Design temperature~120 ℃

Explanation of pump model meaning:

Structural features:The IH series pump is foot supported and can withstand external loads directly transmitted to the foundation. The bearing lubrication method is thin oil lubrication, controlled by a constant position oil cup to ensure that the bearing works in good lubrication condition and has the best service life. The impeller is a closed type impeller, which balances axial forces with back blades or balance holes, and residual axial forces are balanced by bearings. According to different usage situations, shaft seals can be equipped with power seals, single end mechanical seals, double end mechanical seals, or series mechanical seals. Internal flushing, self flushing, and external flushing can be used to flush and cool the mechanical seals. Deep groove ball bearings, cylindrical roller bearings, and angular contact ball bearings are equipped with light and heavy shafts respectively to meet the needs of different loads. The IH series of over 40 pumps only requires 6 types of bearing frames, with strong universality, high standardization, compact and reasonable structure, and good appearance quality. The coupling of the pump is available in claw type, pin type, diaphragm type, etc. for users to choose from. The membrane can be packaged, and there is no need to disassemble the pipeline and motor during maintenance. The bearing frame, shaft, sealing box, impeller components, etc. can be freely disassembled. The inlet flange of the pump is horizontally suction, and the outlet flange is vertically upward. From the motor end, the pump shaft rotates clockwise.

Performance parameter table








Users should pay strict attention when using it

1、 Lubricating oil should be added to the bearing box, and the oil level should be controlled at the middle level of the oil window.

2、 Before driving, manually rotate the coupling to check for any jamming during installation. If there are any scratches or abnormalities, they should be eliminated.

3、 Before starting, connect the coolant flushing solution first. When stopping, stop the vehicle first and then turn off the coolant flushing solution.

4、 The cooling flushing fluid must be clean, non scaling soft water, so newly installed pipelines and storage tanks should be flushed clean. Prevent solid substances from entering the mechanical seal and affecting the sealing effect and service life. Water that is prone to scaling can block the cooling flushing fluid pathway. It will also affect the effectiveness and lifespan of the seal.

5、 The use of condensed water as a sealing flushing solution is ideal, with a temperature below 85 ℃.

6、 The pressure of the cooling flushing liquid is 0.1~0.3 MPa, and the flow rate is 0.63 m3/h. If the flow rate is too small, it will affect the service life of the seal.

Troubleshooting methods and ordering instructions

fault

reason

solution

Export without displacement

1. The pump is not filled with liquid

2. There is air intake in the suction pipeline

3. Installation height too high, input hot or easily vaporized medium

4. Turn back

5. Require the head to be greater than the head

1. Recharge liquid

2. Repair the pipeline

3. Reduce the installation height of the pump

4. Change direction

5. Choose a new pump

Insufficient traffic

1. The bottom valve is too small

2. The suction pipeline is not deeply immersed in the liquid, and air is brought into the pump

3. The suction pipe diameter is too small and blocked by debris

4. The discharge pipe is too thin, and the pipeline loss is too small

5. Impeller wear

1. Configure large bottom valve

2. Increase immersion depth

3. Replace the thick tube and remove any debris

4. Replace the discharge pipeline

5. Replace the impeller

High vibration noise

1. The pump is not concentric with the motor shaft

2. Pump shaft bending

3. Loose impeller nut

4. There are debris entering the pump

5. Bearing damage

1. Calibrate the pump and motor axis line

2. Remove the straightening or replace the shaft with a new one

3. Unload the pump and tighten the impeller nut

4. Unload the pump and remove debris

5. Replace bearings

Bearing overheating

1. Oil cup without oil

2. The pump shaft and motor shaft are not aligned

1. Keep going

2. Two axis alignment

Ordering Instructions

Properties of the conveying medium

Performance parameters of the pumpLiquid name and composition

Flow usage temperature and temperature variation range

Head viscosity

Import pressure ratio

Outlet pressure saturated steam pressure (at operating temperature)

NPSHa value concentration

PH value

pump structureName, size, specific gravity, and content of solid particles contained

Is there any precipitation or crystallization of the material in the overcurrent section of the pump

Sealing form motor

Export direction form, speed, voltage, frequency

Caliber spare parts, special accessories

Flange specifications special requirements

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!