VIP member
Hot test chamber
Product use: The thermal test chamber is used in schools, scientific research, factories, military electrical and electronic products or materials to
Product details
| Equipment model | Studio size (D * W * H) mm | Dimensions (D * W * H) mm | |
| LRHS-101B-LS | 450×450×500 | 1160×1000×1610 | |
| LRHS-225B-LS | 500×600×750 | 1210×1150×1870 | |
| LRHS-504B-LS | 700×800×900 | 1260×1340×2070 | |
| LRHS-800B-LS | 800×1000×1000 | 1370×1550×2170 | |
| LRHS-1000B-LS | 1000×1000×1000 | 1560×1550×2170 | |
|---|---|---|---|
| sexually ability finger treetop |
temperature range | A:-20℃~150℃ B:-40℃~150℃ C:-60℃~150℃ D:-70℃~150℃ |
|||||
| temperature uniformity | ≤ 2 ℃ (when unloaded) | ||||||
| temperature fluctuation | ± 0.5 ℃ (when unloaded) | ||||||
| Time setting range | 1~9999H | ||||||
|---|---|---|---|---|---|---|---|
| Humidity range | 20%~98% RH | ||||||
| humidity uniformity | +2% -3% RH | ||||||
| Humidity fluctuation | ±2% | ||||||
| heating rate | 1.0~3.0℃/min | ||||||
| cooling rate | 0.7~1.0℃/min | ||||||
| test hole | Installed on the left side of the machine, used for external testing of power or signal lines | ||||||
| Observation window | 210 × 275mm or 395 × 395mm (effective field of view) | ||||||
| send use material material |
External material | High quality A3 steel plate electrostatic spraying | |||||
| Inner box material | Imported high-grade stainless steel SUS304 | ||||||
| Insulation material | Rigid polyurethane foam+glass fiber | ||||||
| pit the heart join in marriage place |
temperature controller | Korean ternary TEMI300 | |||||
| temperature sensor | PT100 platinum resistance thermometer | ||||||
| Cooling method | Single machine or double machine cascade refrigeration | ||||||
| compressor | Taikang, France | ||||||
| Standard configuration | 1 roll of wet ball gauze, 2 layers of sample rack, equipped with a condensate water collection tray, and discharged outside the box | ||||||
| Safety protection | Compressor overpressure overload, fan motor overheating, whole machine under phase/reverse phase Overtemperature, overall equipment timing, leakage protection, overload and short circuit protection |
||||||
| supply voltage | AC380V±10% 50Hz | ||||||
| Power | (A)3.5kW/4.0kW/6.0kW/8.0kW/9.0kW (B)4.0kW/4.5kW/7.5kW/9.0kW/10.5kW (C)4.5kW/6.5kW/9.0kW/13.0kW/13.0kW |
||||||
| Usage environment | 5℃~+28℃ ≤85% RH | ||||||
| Note: 1. The above data were measured under good ventilation conditions at an ambient temperature of 25 ℃ 2. Customized high and low temperature wet heat test rooms can be customized according to specific testing requirements of users 3. This technical information is subject to change without prior notice |
|||||||
Online inquiry