Hongrun NHR-A31 series current input detection terminal isolation gate
This product converts current signals from hazardous areas into voltage, current, RS485 signals, or switch signals, and isolates them from hazardous a
Product details

Product Introduction

Single and dual input, single and dual output
The output signal type needs to be specified
The output signal is an analog signal, RS-485 signal, or switch signal

summary
This product converts voltage signals from hazardous areas into voltage, current, RS485 signals, or switch signals, and isolates them from hazardous areas to safe areas. The product requires independent power supply, with input/output/power isolation. Can be used in voltage signal output devices.
safety certification
Certificate No CNEx11.0455
Explosion proof sign [Exia] IIC (National Explosion proof Safety Supervision and Inspection Station Certification for Instruments and Meters)
Authentication parameters
terminal 8-7, 11-10
Maximum allowable voltage Um=250V
voltage Uo=13.65V
electric current Io=9mA
power Po=31mW
capacitance Co=0.5μF
inductance Lo=150mH
Wiring diagram


Analog output wiring diagram


RS485 output wiring diagram


Switching output wiring diagram

terminal number Terminal Description
Safe Zone (Green) 1 OUT1(+)/B
2 OUT1(-)/A
3 OUT2(+)
4 OUT2(-)
5 POW(+)
6 POW(-)
Dangerous Zone (Blue) 7 In1(-)
8 In1(+)
10 In2(-)
11 In2(+)
Structural Outline Drawing

EVT: Work indicator light: When the instrument is working normally, the indicator light is green; When there is a fault alarm in the input signal; The indicator light is red
35mm guide rail installation, please pay attention to stable and firm positioning during installation
Please install it vertically as much as possible to facilitate heat dissipation inside the instrument
Technical Parameter
power supply
Rated working voltage range DC24V±10%
power consumption

RS-485 output: ≤ 0.7W
Analog output: ≤ 1.4W (single channel), ≤ 1.8W (dual channel)
Switching output: ≤ 1.4W

Dangerous side
Input Signal Type 0-5V, 1-5V, 0-5V square root, 1-5 square root
(Determine or configure programming when placing an order and program it yourself)
Input impedance ≥510KΩ
Safety side
Output signal type Analog output, RS-485 signal output, switch output
Output load characteristics When outputting current: RL ≤ 500 Ω, when outputting voltage: RL ≥ 250K Ω
RS485 signal output Transmission delay ≤ 10 μ s, signal transmission rate ≤ 9.6kbps
Switching Output Relay output driving capability: 125VAC/0.6A, 30VDC/2A
Relay response time:<5ms
Transistor collector output: High level VCC (≤ 30V), low level ≤ 2.5V
Transistor emitter output: high level VCC-2.5V, low level ≤ 0.5V
Measurement accuracy 0.2% FS ± 1 word
Insulation strength
Local security end and non local security end 2500V,a.c; 1min
environmental condition
Environmental temperature 0~50℃
ambient humidity 5% to 95% RH (non condensing)
standard
electromagnetic compatibility Compliant with GB/T18268 Industrial Equipment Application Requirements

Instrument selection

7 8 9
Voltage input detection terminal isolation gate NHR-A31 - - /
position specifications notes

|
|
|

|
|
|
|
|
|
|
|
|
|
|
|
|















/
|
|
|
|
|
|
|
|
|
|
|
|
|

7 <Input>
Input I/Input II<Select code from list>
code Type
X No input (limited to the second channel only)
28 0-5V
29 1-5V
34 0-5V square root
35 1-5V square root
8/9 <Output>
Output I/Output II (select code from list)
code type
X No output (limited to the second channel only)
0 4-20mA analog output
1 1-5V
2 0-10mA
3 0-5V
4 0-20mA
5 0-10V (non switchable)
D1 RS485 output (limited to channel I only) 485 output
K1 Relay circuit contact Switching Output
K2 transistor
Note: When the instrument has two outputs, there are three modes to choose from:
a、 Analog output+Analog output
b、 485 output+analog output
c、 Switching output+Switching output
Model example: NHR-A31-29/29-0/0