Handheld gas detector F-920 can quickly and reliably measure the concentration of pollutants in the surrounding environment CO2And O2The concentration. The instrument is easy to operate and quality control personnel do not need to undergo pre training. Lightweight and handheld design facilitates gas detection throughout the entire supply chain from modified atmosphere packaging (MAP) and food packaging to sales. |
|
|
CO2Measurement range: 0% -100% O2Measurement range: 0% -100% Measurement response time:<6 seconds Historical measurement data can be accessed at any time Handheld design, compact and lightweight Battery life: 8h High definition LCD screen Wide range of temperature and humidity that can be used Simple data transmission operation |
![]() |
|
Measurement parameters: Carbon dioxide and oxygen concentration, date, time, humidity, temperature, GPS positioning data | |
|
Application areas: 1. Quality Assurance of Modified Atmosphere Packaging 2. Packaging Chain 3. Laboratory 4. Import and export testing 5. Distribution Center 6. Retail Center 7. Environmental testing 8. Inspection process 9. Storage facilities 10. Ripening room 11. Transport container |
Main technical parameters: 1. Intake speed: 70 mL/min 2. Total sampling time: 10 seconds 3. Data storage: automatically saved every 1 second 4. Display: Backlit, Sunlight Visible, Translucent LCD Screen 5. Operating environment: 0-50 ℃ (0-90% RH, no condensation) 6. Operating environment pressure: 500-1200 mbar 7. Size: 18cm × 13.5cm × 5.5cm 8. Weight: 0.95kg 9. Shell: Powder coated aluminum alloy profile 10. Power supply: rechargeable lithium battery 11. Data transfer: USB and SD card 12. Data recording: CO2 concentration, O2 concentration, date, time, relative humidity, GPS data |
|
Trigger mode measurement: | |
CO2 |
O2 |
|
sensor type |
infrared |
electrochemistry |
measuring range |
0-100% |
0-100% |
resolving power: |
0.01% |
0.10% |
Low detection limit: |
0.50% |
0.30% |
Sample volume: |
10ml |
10ml |
Response time: |
10 s |
10 s |
| Absolute accuracy: | 0.50% |
0.30% |
Real time accuracy: |
3% |
2% |
Zero point calibration: |
every week |
every week |
Span calibration: |
12 months |
6 of them |
service life: |
>15 years |
2 years |
Continuous mode measurement: | ||
| CO2 | O2 | |
Sensor type: |
infrared |
electrochemistry |
Measurement range: |
0-100% |
0-100% |
resolution |
0.01% |
0.1% |
Low detection limit: |
0.01% |
0.1% |
Response time: |
10 s |
5 s |
| Absolute accuracy: | 0.01% |
0.1% |
| Real time accuracy: | 3% |
2% |
Zero point calibration: |
every week |
every week |
Span calibration: |
12 months |
6 months |
service life: |
>15 years |
2 years |
Purchasing Guide:
Host, operating manual, box, and related accessories
Basic configuration:

Application example:
![]() |
|
Origin: Felix, USA