HW-20B desktop multi-channel signal generation verification device
The HW-20B multi-channel signal generator/calibrator can simulate sensors and transmitters of various industrial process instruments, output 11 standa
Product details
The HW-20B multi-channel signal generator/calibrator can simulate sensors and transmitters of various industrial process instruments, output 11 standard signals simultaneously, and measure various signals generated by process instruments. Therefore, it is suitable for debugging and calibration of new generation automation instruments and automatic control systems. Due to the fact that the HW-20B is equipped with a 24VDC output for testing two-wire instruments, the use of the HW-20B multi-channel signal generator/calibrator allows for easy and accurate debugging and testing of multiple instruments without the need for additional instruments.
★High precision, level 0.05
★Can simultaneously output 11 signals and input 4 signals
★Built in isolated DC24V output
★220V AC power supply
★current outputMaximum 20mA, 4 independent channels, accuracy level 0.05; Load resistance: RL≤1500Ω@(0~10mA)
RL≤750Ω@(0~20mA)
★Millivolt output:Maximum 120mV, accuracy level 0.05, load resistance: RL≥10K
★voltage output:Maximum 6V, accuracy level 0.05, load resistance: RL≥10K
★frequency output:F1,F2, Maximum 10000Hz, maximum error 2Hz, maximum amplitude: ≈ 15V
F3,F4, Maximum 1000.0Hz, maximum error 0.2Hz
★Resistance output:0~390Ω
★current measurement:0~20mA,Ri=100 Ω, accuracy level 0.05
★Millivolt measurement:0~200mV,Ri=10M Ω, accuracy level 0.05
★voltage measurement:0~20V,Ri=10M Ω, accuracy level 0.05
★frequency measurement:0~20kHz, Sensitivity: Vp-p≥500mV, Accuracy: 0.02% ± 1 word
★Operating temperature:-10℃~50℃
★ambient humidity≤ 95% relative humidity, no condensation
★electricity sourceAC 220V ± 10%, 50Hz
| feature |
★Can simultaneously output 11 signals and input 4 signals
★Built in isolated DC24V output
★220V AC power supply
| Technical indicators (effective ambient temperature:23±5℃) |
RL≤750Ω@(0~20mA)
★Millivolt output:Maximum 120mV, accuracy level 0.05, load resistance: RL≥10K
★voltage output:Maximum 6V, accuracy level 0.05, load resistance: RL≥10K
★frequency output:F1,F2, Maximum 10000Hz, maximum error 2Hz, maximum amplitude: ≈ 15V
F3,F4, Maximum 1000.0Hz, maximum error 0.2Hz
★Resistance output:0~390Ω
★current measurement:0~20mA,Ri=100 Ω, accuracy level 0.05
★Millivolt measurement:0~200mV,Ri=10M Ω, accuracy level 0.05
★voltage measurement:0~20V,Ri=10M Ω, accuracy level 0.05
★frequency measurement:0~20kHz, Sensitivity: Vp-p≥500mV, Accuracy: 0.02% ± 1 word
★Operating temperature:-10℃~50℃
★ambient humidity≤ 95% relative humidity, no condensation
★electricity sourceAC 220V ± 10%, 50Hz
Online inquiry