Wuhan Huatian Power Automation Co., Ltd
Home>Products>HTJS-M inter frequency dielectric loss tester
HTJS-M inter frequency dielectric loss tester
Integrated model with reverse wiring low-voltage shielding function, equipped with standard capacitors and high-voltage power supply, convenient for o
Product details

Product IntroductionProduct Introduction

Dielectric loss measurement is a fundamental method in insulation testing, which can effectively detect the overall moisture degradation and deterioration of electrical equipment insulation, as well as local defects. Widely used in electrical manufacturing, electrical equipment installation, handover, and preventive testing. The measurement of dielectric loss of transformers, mutual inductors, reactors, capacitors, bushings, lightning arresters, etc. is a fundamental method for measuring their insulation performance. The HTJS-M variable frequency dielectric loss tester breaks through the traditional bridge measurement method, adopts variable frequency power supply technology, and uses microcontrollers and modern electronic technology for automatic frequency conversion, analog-to-digital conversion, and data operation; Achieve strong anti-interference ability, fast testing speed, high accuracy, fully automatic digitization, and easy operation; The power supply adopts a high-power switching power supply, which outputs pure sine waves at 45Hz and 55Hz, automatically applies voltage, and can provide a maximum voltage of 10 kV; Automatically filter out 50Hz interference, suitable for on-site testing in substations and other areas with high electromagnetic interference. Widely applicable for dielectric loss measurement of transformers, mutual inductors, bushings, capacitors, lightning arresters and other equipment in the power industry.

Product Name: Dielectric Loss Tester, Anti Interference Dielectric Loss Tester, Fully Automatic Dielectric Loss Tester, Off Frequency Dielectric Loss Tester, Off Frequency Dielectric Loss Tester, Anti Interference Dielectric Loss Tester, Fully Automatic Dielectric Loss Tester

Product ParametersProduct Parameters

Technical Specifications

accuracy Cx ± (reading x 1%+1pF)
tgδ ± (reading x 1%+0.00040)
Anti-interference index Frequency conversion anti-interference, can still achieve the above accuracy under 200% interference
Range of capacitance Apply high pressure internally 3pF~60000pF/10kV 60pF~1μF/0.5kV
Apply high pressure externally 3pF~1.5μF/10kV 60pF~30μF/0.5kV
resolution Maximum 0.001pF, 4 significant digits
Range of TG δ Unrestricted, with a resolution of 0.001%, automatic identification of three types of samples: capacitance, inductance, and resistance
Test current range 10μA to 1A
Apply high pressure internally Set voltage range 0.5~10kV
Maximum output current 200mA
Boosting and lowering method Continuous smooth adjustment
Test frequency: 45, 50, 55, 60, 65Hz single frequency; 45/55Hz, 55/65Hz, 47.5/52.5Hz automatic dual frequency conversion
frequency accuracy ±0.01Hz
Apply high pressure externally The maximum test current when connected in a positive direction is 1A, with a frequency range of 40-70Hz for power frequency or variable frequency
The maximum test current during reverse wiring is 10kV/1A, with a frequency range of 40-70Hz for power frequency or variable frequency
CVT self-excited low-voltage output method Output voltage 3-50V, output current 3-30A
measure time About 40 seconds, depending on the measurement method
input power 180V~270VAC, 50Hz ± 1%, powered by mains or generator
computer interface Standard RS232 interface
printer Thermal micro printer
ambient temperature -10℃~50℃
relative humidity <90%
Overall dimensions 460×360×350mm3
instrument weight 28kg
Note:

1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued.

2. To learn more about Huatian products, please enter the product center. Service Hotline: 400-8855-448

Product featuresProduct Characteristics

  • 1. The instrument adopts the complex current method to measure capacitance, dielectric loss, and other parameters. The test results have high accuracy, making it easy to achieve automated measurement.

  • 2. The instrument adopts frequency conversion technology to eliminate on-site 50Hz power frequency interference, and reliable data can be measured even in strong electromagnetic interference environments.

  • 3. The instrument adopts a large screen LCD display, and the testing process is both intuitive and easy to operate through Chinese character menu prompts.

  • 4. The instrument is easy to operate, and the measurement process is controlled by a microprocessor. As long as the appropriate measurement method is selected, the data measurement can be automatically completed under the control of the microprocessor.

  • 5. Integrated model, equipped with standard capacitors and high-voltage power supply, convenient for on-site testing and reduces on-site wiring.

  • 6. The instrument has high measurement accuracy and can meet the requirements of oil dielectric loss measurement. Therefore, only a standard oil cup and a dedicated testing line are needed to achieve oil dielectric loss measurement.

  • 7. The CVT testing function can achieve self-excited testing of CVT without the need for external accessories. Only one measurement is required to measure the capacitance and dielectric loss of C1 and C2.

  • 8. The reverse wiring test adopts IVDDV technology, eliminating the previous phenomenon of unstable reverse wiring data.

  • 9. Equipped with reverse wiring low-voltage shielding function, C11 can perform 10kV reverse wiring dielectric loss measurement without disconnecting the wire when the 220kV CVT bus is grounded.

  • 10. It has the function of measuring high voltage dielectric loss and can use high-voltage transformers or series resonance to conduct dielectric loss tests exceeding 10kV voltage.

  • 11. Grounding protection function: When the instrument is not grounded or poorly grounded, it will not enter the normal program and will not output high voltage. The overcurrent protection function ensures that the instrument is not damaged in the event of a short circuit or breakdown of the test sample.

  • 12. Electric shock protection function: When the instrument operator accidentally gets an electric shock, the instrument will immediately cut off the high voltage to ensure the safety of the test personnel.

product videoProduct Video

Product AtlasProduct Picture

Product Attachment Diagram

host

high-voltage cable

low voltage cable

power cord

ground wire

CVT line

5A insurance tube (built-in)

printing paper

Instruction manual, inspection certificate, certificate of conformity

Product detail images

instrument panel

screen

Test end

power switch

input terminal

Test line port

attachment package

outer box

Product CertificateProduct Certificate

Our company's products are strictly produced in accordance with international and national standards and industry regulations. They have passed the testing of national, provincial, and municipal power research institutes, measurement centers, and authoritative power departments, and have fully passed the ISO9001 international quality management system certification, the People's Republic of China manufacturing measuring instrument license, GB/T19001-2016 quality management system requirements, GB/T24001-2016 environmental management system requirements, and GB/T45001-2020 occupational health and safety management system requirements.

  • c1
  • c2
  • c3
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!