HINL100A/200A series signal converter
This converter receives process signals such as flow rate, pressure, and temperature, and converts them into insulation unified signals. High reliability, diverse models can be used for various purposes.
-
characteristic
-
Product Overview
-
specifications
characteristic
- Use plugin structure to be detachable
- Aluminum electrolytic capacitors with limited lifespan are not used.
100A series
Insulation 1 output (DC4~20mA or DC1~5V output, specified when ordering)
200A series
Insulation 2 output (DC4~20mA or DC1~5V output, specified at the time of ordering), can be used independently for monitoring and control.
Product Overview
model | product name |
---|---|
100TCA/200TCA | Thermocouple temperature converter |
100TRA/200TRA | Temperature measuring resistor temperature converter |
100MVA/200MVA | MV converter |
100PRA/200PRA | Sliding resistance converter |
100DLA/200DLA | splitter |
100DRA/200DRA | Diverter (with square root operation) |
100ICA/200ICA | Insulation components |
100VIA/200VIA | Voltage current converter |
specifications
model | 100TCA | 100TRA | 100MVA | 100PRA |
---|---|---|---|---|
Input signal | JIS specification thermocouple R,K,E,J,T,S,B,N |
JIS specification temperature measuring resistor Pt100 |
mV,V,mA | Potentiometer 130~2000Ω |
output signal | Insulation 1 output: DC1-5V or DC4-20mA (specified when ordering) | |||
Allowable output signal load resistance |
DC1-5V output: above 2k Ω DC4-20mA output: below 750 Ω |
|||
Conversion accuracy | ±0.4%FS(Note 1) | ±0.25%FS(Note 1) | ±0.2%FS(Note 1) | ±0.25%FS |
supply voltage | AC85-132V 50/60Hz or DC24V (specified when ordering) | |||
Power consumption (VA) (During AC100V operation) |
2.8 | 2.8 | 2.8 | 2.9 |
Insulation components | Input output power supply have mutual connections | |||
pressure resistance | Between power terminal and ground terminal: AC2000V, 1 minute Input output power mutual: AC2000V, 1 minute |
|||
insulation resistance | Between each terminal and the grounding terminal: 100M Ω/DC500V | |||
install | DIN rail or wall mounted | |||
weight | Host: about 220g, socket: about 60g | |||
Function switch | - | - | - | - |
model | 100DLA | 100DRA | 100ICA | 100VIA |
---|---|---|---|---|
Input signal | 2-wire transmitter (nominal DC24V) | DC1-5V or DC4~20mA (specified when ordering) |
Various voltage and current signals | |
output signal | Insulation 1 output: DC1-5V or DC4-20mA (specified when ordering) | |||
Allowable load resistance of output signal | DC1-5V output: above 2k Ω DC4-20mA output: below 750 Ω |
|||
Conversion accuracy | ±0.2%FS | ±0.3%FS | ±0.2%FS | ±0.2%FS(Note 1) |
supply voltage | AC85-132V 50/60Hz or DC24V (specified when ordering) | |||
Power consumption (VA) (During AC100V operation) |
3.7 | 3.7 | 2.8 | 2.8 |
Insulation components | Input output power supply have mutual connections | |||
pressure resistance | Between power terminal and ground terminal: AC2000V, 1 minute Input output power mutual: AC2000V, 1 minute |
|||
insulation resistance | Between each terminal and the grounding terminal: 100M Ω/DC500V | |||
install | DIN rail or wall mounted | |||
weight | Host: about 220g, socket: about 60g | |||
Function switch | Transmitter power supply: ON/OFF |
Transmitter power supply: ON/OFF |
- | - |
(Note 1) Accuracy may vary with input specifications, range, and displayed values. Please refer to the CS table for confirmation.
model | 200TCA | 200TRA | 200MVA | 200PRA |
---|---|---|---|---|
Input signal | JIS specification thermocouple R,K,E,J,T,S,B,N |
JIS specification temperature measuring resistor Pt100Ω |
mV,V,mA | Potentiometer 130~2000Ω |
output signal | Insulation 2 output: Output DC1-5V or DC4-20mA (specified when ordering) | |||
Allowable output signal load resistance |
DC1-5V output: above 250k Ω (first output), above 2k Ω (second output) DC4-20mA output: below 750 Ω (first output), below 350 Ω (second output) |
|||
Conversion accuracy |
±0.4%FS |
±0.25%FS(Note 1) | ±0.2%FS(Note 1) | ±0.25%FS |
supply voltage | AC85-132V 50/60Hz or DC24V (specified when ordering) | |||
Power consumption (VA) (During AC100V operation) |
3.3 | 3.3 | 3.3 | 3.4 |
Insulation components | Input - first output - second output - power supply are mutually available | |||
pressure resistance | Between power terminal and ground terminal: AC2000V, 1 minute Input output power mutual: AC2000V, 1 minute Output mutual: AC1000V, 1 minute |
|||
insulation resistance | Between each terminal and the grounding terminal: 100M Ω/DC500V | |||
structure | Lightweight plug-in structure (plug: dedicated 11 hole plug, screw terminal M3) | |||
install | DIN rail or wall mounted | |||
weight | Host: about 220g, socket: about 80g | |||
Function switch | - | - | - | - |
model | 200DLA | 200DRA | 200ICA | 200VIA |
---|---|---|---|---|
Input signal | 2-wire transmitter (nominal DC24V) | DC1-5V or DC4~20mA (specified when ordering) |
Various voltage and current signals | |
output signal | Insulation 2 output: DC1-5V/DC4-20mA output (specified when ordering) | |||
Allowable output signal load resistance |
DC1-5V output: above 250k Ω (first output), above 2k Ω (second output) DC4-20mA output: below 750 Ω (first output), below 350 Ω (second output) |
|||
Conversion accuracy | ±0.2%FS | ±0.3%FS | ±0.2%FS | ±0.2%FS(Note 1) |
supply voltage | AC85-132V 50/60Hz or DC24V (specified when ordering) | |||
Power consumption (VA) (During AC100V operation) |
4.2 | 4.2 | 3.3 | 3.3 |
Insulation components | Input - first output - second output - power supply are mutually available | |||
pressure resistance | Between power terminal and ground terminal: AC2000V, 1 minute Input output power mutual: AC2000V, 1 minute Output mutual: AC1000V, 1 minute |
|||
insulation resistance | Between each terminal and the grounding terminal: 100M Ω/DC500V | |||
install | DIN rail or wall mounted | |||
weight | Host: about 220g, socket: about 80g | |||
Function switch | Transmitter power supply: ON/OFF |
Transmitter power supply: ON/OFF |
- | - |
(Note 1) Accuracy may vary with input specifications, range, and displayed values. Please refer to the CS table for confirmation.