HI96733Ammonia nitrogen (HR) portable waterproof photometerIntroduction:
Measurement range: 0.0 to 50.0 mg/L (ppm) NH4+
Adopting innovative optical system design, with excellent precision, repeatability, and measurement time required, Hanna's carefully designed CAL Check ™ The function allows for performance validation and calibration of instruments using NIST traceable standards, multiple measurement methods, users can choose to use powder or water reagents, built-in reaction timer to ensure results between sample measurement and user *, Good Laboratory Practice (GLP) display of the last user calibration date and time, battery status indicator light, and automatic shutdown setting.
Reminder: The new HI97733 ammonia nitrogen analyzer adopts a menu operation mode. Select "Chemical Form" from the menu and press the "▼▲" key to convert. The ammonia [NH3] reading will be converted to ammonia nitrogen [NH3-N] reading or ammonium [NH4+] reading
HI96733Ammonia nitrogen (HR) portable waterproof photometerparameter
|
Ammonia nitrogen mainly comes from the microbial decomposition products of proteins in animals and plants. Due to its toxicity, ammonia nitrogen testing is usually required in aquaculture. Ammonia nitrogen in river water or reservoirs mainly comes from agricultural or civilian pollution. Therefore, ammonia nitrogen measurement is also commonly carried out in lakes, river water, drinking water, boiler inlet water, sewage, and industrial wastewater. The ideal resolution is generally not lower than 0.1mg/L, usually only 0.5mg/L. The ammonia nitrogen spectrophotometer has a combination optical system of narrowband interference filter and silicon photodetector, ensuring accurate measurement readings every time; It is simple and convenient to add reagents to the water sample to be tested. The reagents will react with ammonia nitrogen in the water sample to produce a yellow color. Based on the color change after the reaction between the reagents and the water sample, the ammonia nitrogen concentration value can be determined using an ammonia nitrogen spectrophotometer. Built in timer - ensures that the tested water sample and ammonia nitrogen reagent react according to the internally set standard time. At the end of the timer, the instrument will automatically read the reading, ensuring the consistency of reaction time for multiple batches of measurements. GLP Function - Record the date of the last user calibration execution Error messages - warning issues on the display screen, including unlimited, out of range, and under range readings, as well as light source errors; Automatic shutdown - measurement mode for 10 minutes, or in calibration mode, it will automatically shut down after one hour of inactivity; Battery status - battery level indicator, 【 ▊▊▊ 】 indicates 100% battery level; 【▊▊】 indicates that the battery level is ≤ 60%; 【 ▊ 】 indicates that the battery level is ≤ 30%; When ≤ 10%, the battery icon flashes, prompting the user to replace the battery in a timely manner. |