1UV sterilizerThe working principle of
1.The application wavelength is225-275μmThe peak is254μmThe ultraviolet spectrum has high energy in this band. Can destroy the nucleic acid structure of microorganisms,UV sterilizerIt has a strong bactericidal effect, thus achieving the purpose of disinfection.
2.The equipment can effectively kill Escherichia coli, dysentery bacteria, Legionella, influenza virus, hepatitis virus, etc., purifying water quality.
1.The application wavelength is225-275μmThe peak is254μmThe ultraviolet spectrum has high energy in this band. Can destroy the nucleic acid structure of microorganisms,UV sterilizerIt has a strong bactericidal effect, thus achieving the purpose of disinfection.
2.The equipment can effectively kill Escherichia coli, dysentery bacteria, Legionella, influenza virus, hepatitis virus, etc., purifying water quality.
3..The rates of various viruses and bacteria in seawater, freshwater, or other water bodies treated by this device can reach99.99%The above.
4. With strengthUVThe ultraviolet light source irradiates water. This disinfection system can quickly take effect without any residue, and does not require any potentially hazardous chemicals.
5.The water treatment system willUVThe light source is integrated into the filtering device. A typical complete filtration device has a multi-layer structure, includingUVLight source and a traditional mechanical filter. A series of special light sources, ballasts, and sleeves suitable for integration in filtration devices have been used to achieve ultraviolet water sterilization equipment. This easy-to-use and easy to install technology can protect community residents from the threat of diseases caused by microorganisms such as bacteria and viruses carried by water. Suitable solutions for different market demands, able to meet the special needs and installation requirements of residents and municipal drinking water, wastewater treatment, industrial water, swimming pools, and other leisure facilities.
6.The UV sterilization equipment adopts an integrated design of a controller and a water processor (if necessary, a special component can be designed). The controller consists of a UV lamp working indicator circuit, a programmable time controller, a time accumulation controller, and an electronic ballast; The water treatment unit consists of a closed pressure cylinder, inlet and outlet pipes, an automatic cleaning quartz sleeve, ultraviolet light tubes, and left and right heat dissipation covers for the tubes.
IIUV sterilizerScope of application:
1.A small-scale water supply system that uses rivers, lakes, ponds, and well water as its sources.
2.The water supply system for the high water tank, backup water tank, and backup reservoir.
3.Food, pharmaceutical, beverage, and liquor industries.
4.Various water supply systems that require sterilization and disinfection.
3、 Model Description:
1.UV sterilizer
2.Specification and model, inlet and outlet specifications
3.Import and export types(P: LevelZ: Vertical)
4.Rated working pressure of the system: (unit:)MPA)
4、 The use of water quality conditions is related to chromaticity and iron content. Therefore, for the water to be treated entering this equipment, namely the inlet water conditions,The water quality conditions for its use are: turbidity ≤5Total iron content ≤0.3mg/LChromaticity ≤15Temperature of water ≥5℃.
5UV sterilizerWater performance indicators
sterilization rate99%Escherichia coli is0cuf/100ml, in accordance withCJ94-1999The "Drinking Water Quality Standards" stipulated in the "Industry Standards for Urban Construction of the People's Republic of China".
4. With strengthUVThe ultraviolet light source irradiates water. This disinfection system can quickly take effect without any residue, and does not require any potentially hazardous chemicals.
5.The water treatment system willUVThe light source is integrated into the filtering device. A typical complete filtration device has a multi-layer structure, includingUVLight source and a traditional mechanical filter. A series of special light sources, ballasts, and sleeves suitable for integration in filtration devices have been used to achieve ultraviolet water sterilization equipment. This easy-to-use and easy to install technology can protect community residents from the threat of diseases caused by microorganisms such as bacteria and viruses carried by water. Suitable solutions for different market demands, able to meet the special needs and installation requirements of residents and municipal drinking water, wastewater treatment, industrial water, swimming pools, and other leisure facilities.
6.The UV sterilization equipment adopts an integrated design of a controller and a water processor (if necessary, a special component can be designed). The controller consists of a UV lamp working indicator circuit, a programmable time controller, a time accumulation controller, and an electronic ballast; The water treatment unit consists of a closed pressure cylinder, inlet and outlet pipes, an automatic cleaning quartz sleeve, ultraviolet light tubes, and left and right heat dissipation covers for the tubes.
IIUV sterilizerScope of application:
1.A small-scale water supply system that uses rivers, lakes, ponds, and well water as its sources.
2.The water supply system for the high water tank, backup water tank, and backup reservoir.
3.Food, pharmaceutical, beverage, and liquor industries.
4.Various water supply systems that require sterilization and disinfection.
3、 Model Description:
1.UV sterilizer
2.Specification and model, inlet and outlet specifications
3.Import and export types(P: LevelZ: Vertical)
4.Rated working pressure of the system: (unit:)MPA)
4、 The use of water quality conditions is related to chromaticity and iron content. Therefore, for the water to be treated entering this equipment, namely the inlet water conditions,The water quality conditions for its use are: turbidity ≤5Total iron content ≤0.3mg/LChromaticity ≤15Temperature of water ≥5℃.
5UV sterilizerWater performance indicators
sterilization rate99%Escherichia coli is0cuf/100ml, in accordance withCJ94-1999The "Drinking Water Quality Standards" stipulated in the "Industry Standards for Urban Construction of the People's Republic of China".
6、 Technical indicators
1.Input power supply:220V,50Hz;
2.Adapt to water temperature:≤60℃;
3.working pressure:≤1.6MPa;
4.Service life10-15Year;
5.Product specifications: Inlet and outlet diameterDN20~300.
1.Input power supply:220V,50Hz;
2.Adapt to water temperature:≤60℃;
3.working pressure:≤1.6MPa;
4.Service life10-15Year;
5.Product specifications: Inlet and outlet diameterDN20~300.
UV sterilizerCharacteristics
UV sterilizerIt consists of UV lamp, quartz tube, ballast, seal, tank, inlet and outlet, and other parts.
◎ Adopting the world's American Lysos low-voltage high-strength ultraviolet lamp tube, the service life of the lamp tube is guaranteed to be over 12000-13000 hours.
Select high transmittance and high-purity quartz sleeves to ensure that ultraviolet rays pass through at least 90% and withstand a pressure of over 15MPa.
◎ Choose the world's advanced constant and high-intensity ultraviolet special ballasts to ensure the maximum actual output of the ultraviolet lamp power, which can guarantee the normal operation of the entire system in complex situations.
Select high-quality stainless steel as the reactor (304 material, 316 material), and perform special polishing treatment on the inner wall of the reactor to improve the sterilization effect.
The sound and light alarm system can promptly reflect whether the equipment is working properly.
Equipped with a time control system, it can control the working status of the system in different time periods to achieve energy conservation.
◎ UV intensity monitor, timely monitoring of UV light intensity to ensure sterilization effect.
◎ Diode fuse ensures the safety and stability of the system in case of abnormal power supply.
◎ Cleaning system: The cleaning system is divided into manual cleaning and automatic cleaning for different users to choose from.
The power supply is generally 220V50Hz, and can also be customized according to different users for various voltage and frequency bands.
The exterior design conforms to fluid dynamics, ensuring that the equipment has no dead corners and that the ultraviolet radiation intensity inside the equipment cavity is uniform and uniform.
The equipment is designed according to the NSF TITLE 55 standard in the United States, with an effective dose of over 99.9%.
7UV sterilizerSelection principles and precautions
1.This device can only disinfect and sterilize, and cannot change other indicators of water, such as color, turbidity, etc. If these indicators exceed the standard, other methods need to be used for handling;
2.When the original water quality exceeds the national drinking water standards, such as: chromaticity higher than15The degree and turbidity are higher than5The degree and iron content are higher than0.3milligram/To achieve the standard of purification, other methods should be used first, and then treated with a UV sterilizer; The total number of bacteria exceeds3000a/Milliliters and coliform bacteria exceeding800a/Milliliters should be connected in series or the flow rate should be reduced as appropriate to achieve disinfection and sterilization standards.
3.UV lamps are vulnerable parts and need to be replaced when their lifespan expires.
8、 Installation and use
1.The equipment must be installed horizontally, with gaps at both ends1.5riceand0.4riceSpace for replacing light tubes;
2.The quartz sleeve and lamp tube inside the equipment are fragile items, and attention should be paid during installation and transportation;
3.Special attention should be paid to protecting the exhaust port of the ultraviolet lamp tube when installing it (there is a noticeable protrusion on one end of the tube wall). The exhaust port should be slowly pushed into the sleeve, and collision with the exhaust port is strictly prohibited, otherwise it will cause damage to the lamp tube;
4.UV sterilizerShall not bear the weight of external pipelines;
5.Pipeline installation should be carried out according to the schematic diagram. globe valve1Main pipeline valve, closed during normal operation, globe valve2、3The inlet and outlet valves of the ultraviolet sterilizer are in the open state during normal operation, and the sampling valve1、2To detect the water inlet;
6.After the pipeline installation is completed, the outlet valve should be opened first, and then the inlet valve should be slowly opened to ensure that the internal mechanism of the ultraviolet sterilizer is not strongly impacted by the water flow and can enter the working state normally;
7.If the sterilization equipment alarms during use, open the protective covers on both sides and replace the indicated light tube;
8.At least two consecutive ignitions of the ultraviolet lamp should be spaced apart10Wait for the lamp to cool down before igniting; During use, it is strictly prohibited to exceed the working pressure to prevent damage to the quartz casing.
9、 After sales service
1.warranty12Months, lifetime maintenance;
2.The ultraviolet lamp tube is under warranty, and users can purchase and replace it by themselves outside the warranty period;
3.rightUV sterilizerEquipment damage caused by human error or damage resulting from disassembly and modification is not covered by the warranty.
UV sterilizerIt consists of UV lamp, quartz tube, ballast, seal, tank, inlet and outlet, and other parts.
◎ Adopting the world's American Lysos low-voltage high-strength ultraviolet lamp tube, the service life of the lamp tube is guaranteed to be over 12000-13000 hours.
Select high transmittance and high-purity quartz sleeves to ensure that ultraviolet rays pass through at least 90% and withstand a pressure of over 15MPa.
◎ Choose the world's advanced constant and high-intensity ultraviolet special ballasts to ensure the maximum actual output of the ultraviolet lamp power, which can guarantee the normal operation of the entire system in complex situations.
Select high-quality stainless steel as the reactor (304 material, 316 material), and perform special polishing treatment on the inner wall of the reactor to improve the sterilization effect.
The sound and light alarm system can promptly reflect whether the equipment is working properly.
Equipped with a time control system, it can control the working status of the system in different time periods to achieve energy conservation.
◎ UV intensity monitor, timely monitoring of UV light intensity to ensure sterilization effect.
◎ Diode fuse ensures the safety and stability of the system in case of abnormal power supply.
◎ Cleaning system: The cleaning system is divided into manual cleaning and automatic cleaning for different users to choose from.
The power supply is generally 220V50Hz, and can also be customized according to different users for various voltage and frequency bands.
The exterior design conforms to fluid dynamics, ensuring that the equipment has no dead corners and that the ultraviolet radiation intensity inside the equipment cavity is uniform and uniform.
The equipment is designed according to the NSF TITLE 55 standard in the United States, with an effective dose of over 99.9%.
7UV sterilizerSelection principles and precautions
1.This device can only disinfect and sterilize, and cannot change other indicators of water, such as color, turbidity, etc. If these indicators exceed the standard, other methods need to be used for handling;
2.When the original water quality exceeds the national drinking water standards, such as: chromaticity higher than15The degree and turbidity are higher than5The degree and iron content are higher than0.3milligram/To achieve the standard of purification, other methods should be used first, and then treated with a UV sterilizer; The total number of bacteria exceeds3000a/Milliliters and coliform bacteria exceeding800a/Milliliters should be connected in series or the flow rate should be reduced as appropriate to achieve disinfection and sterilization standards.
3.UV lamps are vulnerable parts and need to be replaced when their lifespan expires.
8、 Installation and use
1.The equipment must be installed horizontally, with gaps at both ends1.5riceand0.4riceSpace for replacing light tubes;
2.The quartz sleeve and lamp tube inside the equipment are fragile items, and attention should be paid during installation and transportation;
3.Special attention should be paid to protecting the exhaust port of the ultraviolet lamp tube when installing it (there is a noticeable protrusion on one end of the tube wall). The exhaust port should be slowly pushed into the sleeve, and collision with the exhaust port is strictly prohibited, otherwise it will cause damage to the lamp tube;
4.UV sterilizerShall not bear the weight of external pipelines;
5.Pipeline installation should be carried out according to the schematic diagram. globe valve1Main pipeline valve, closed during normal operation, globe valve2、3The inlet and outlet valves of the ultraviolet sterilizer are in the open state during normal operation, and the sampling valve1、2To detect the water inlet;
6.After the pipeline installation is completed, the outlet valve should be opened first, and then the inlet valve should be slowly opened to ensure that the internal mechanism of the ultraviolet sterilizer is not strongly impacted by the water flow and can enter the working state normally;
7.If the sterilization equipment alarms during use, open the protective covers on both sides and replace the indicated light tube;
8.At least two consecutive ignitions of the ultraviolet lamp should be spaced apart10Wait for the lamp to cool down before igniting; During use, it is strictly prohibited to exceed the working pressure to prevent damage to the quartz casing.
9、 After sales service
1.warranty12Months, lifetime maintenance;
2.The ultraviolet lamp tube is under warranty, and users can purchase and replace it by themselves outside the warranty period;
3.rightUV sterilizerEquipment damage caused by human error or damage resulting from disassembly and modification is not covered by the warranty.
Attachment 1: Model and Configuration of UV Disinfector
| model | water treatment capacity T/H | Imported pipe diameter mm | power W | work pressure MPa |
| JG-UUVC-300 | 26-30 | 80 | 300 | 0.6 |
| JG-UUVC-360 | 32-35 | 80 | 360 | 0.6 |
| JG-UUVC-400 | 36-40 | 100 | 400 | 0.6 |
| JG-UUVC-480 | 42-46 | 100 | 480 | 0.6 |
| JG-UUVC-500 | 47-50 | 125 | 500 | 0.6 |
| JG-UUVC-600 | 55-60 | 125 | 600 | 0.6 |
| JG-UUVC-720 | 70-75 | 125 | 720 | 0.6 |
| JG-UUVC-840 | 80-85 | 133 | 840 | 0.8 |
| JG-UUVC-960 | 90-95 | 133 | 960 | 0.8 |
| JG-UUVC-1080 | 100-110 | 150 | 1080 | 0.8 |
| JG-UUVC-1200 | 120-130 | 150 | 1200 | 0.8 |
| JG-UUVC-1320 | 140-150 | 200 | 1320 | 0.8 |
| JG-UUVC-600 | 55-60 | 125 | 600 | 0.8 |
| JG-UUVC-750 | 75-80 | 133 | 750 | 0.8 |
| JG-UUVC-900 | 85-90 | 133 | 900 | 0.8 |
| JG-UUVC-1050 | 110-120 | 150 | 1050 | 0.8 |
| JG-UUVC-1200 | 120-130 | 150 | 1200 | 0.8 |
| JG-UUVC-1350 | 150-160 | 200 | 1350 | 0.8 |
| JG-UUVC-1440 | 160-170 | 200 | 1440 | 0.8 |
| JG-UUVC-1500 | 180-200 | 200 | 1500 | 1.0 |
| JG-UUVC-1650 | 220-250 | 250 | 1650 | 1.0 |
| JG-UUVC-1800 | 280-300 | 250 | 1800 | 1.0 |
| JG-UUVC-2400 | 350-400 | 250 | 2400 | 1.0 |
| JG-UUVC-3000 | 460-500 | 250 | 3000 | 1.0 |
| JG-UUVC-4200 | 600-650 | 300 | 4200 | 1.0 |
| JG-UUVC-6000 | 800-900 | 350 | 6000 | 1.0 |
Attachment 2: Model configuration of low flow ultraviolet sterilizer
| model | water treatment capacity T/H | Imported pipe diameter mm | Power W | work pressure MPa |
| JG-UUVC-15 | 0.5 | 15 | 15 | 0.4 |
| JG-UUVC-40 | 1.5-2 | 25 | 40 | 0.4 |
| JG-UUVC-55 | 3-4 | 32 | 55 | 0.4 |
| JG-UUVC-75 | 4-5 | 32 | 75 | 0.6 |
| JG-UUVC-100 | 7-8 | 40 | 100 | 0.6 |
| JG-UUVC-120 | 9-10 | 50 | 120 | 0.6 |
| JG-UUVC-150 | 12-15 | 50 | 150 | 0.6 |
| JG-UUVC-200 | 18-20 | 65 | 200 | 0.6 |
| JG-UUVC-240 | 22-25 | 80 | 240 | 0.6 |
JGUV sterilizer isOSealed with a circular ring, similar in structure to the UK's Hainoway and the US's Prominent, with an internal guide plate and no dead corners for UV irradiation. The control box can be easily disassembled, and the bottom box can be removed, closed, and the ballast can be replaced without disassembling the UV disinfection cylinder. The body material is all food grade304Stainless steel, welded using imported from the United StatesEASAAutomatic welding, smooth weld bead. Smooth and elegant appearance lines.