1、 Measurement principle
Adopting the principle of ion selective electrode, an integrated sensor is composed of a reference electrode, a working electrode, a compensation electrode, and a temperature electrode.
∆ E = E ( I S E ) – E ( R e f )
IIIQ-LabLinkcorrection system
WTWHaving specific technology can ensure that the relative slope of the ion electrode is maintained for a long time95%Therefore, there is no need to frequently calibrate the electrodes. Simply immerse the entire sensor in a pool, take nearby water samples to the laboratory for analysis, and then input the laboratory results into the instrument. This completes the calibration, taking into account factors such as sample composition and background ion intensity, which can ensure good testing accuracy and stability. Combining with usWTWA multifunctional water quality analyzer that only requires oneUThe disk can automatically input laboratory data intoIQIn the system, it is very convenient.
1Safe, fast, and reliable data transmission
2Automatically verify the accuracy of calibration data
3、 Typical applications
Process control and monitoring of sewage treatment plants, installed in the effluent and influent of the biochemical tank, andFDODissolved oxygen electrodes are used in conjunction with accurate aeration systems.
4、 Advantages
1、 Online monitoring of ammonia nitrogen(AmmoLyt)Compensated for potassium ion interference
2、 Online monitoring of nitrate and nitrogen(NitraLyt)Compensated for chloride ion interference
3、 The electrode is protected by a metal film and can be cleaned with a soft brush
4、 Long electrode lifespan
5、 Fast response, suitable for monitoring peak water quality
6、 No need for standard solution calibration, good long-term stability
7、 Can display potassium ion or chloride ion concentration
8、 One compensating electrode can compensate for other sensors of the same series connected to the same controller
9、 Using an electrode(VARiON)Can test both ammonia nitrogen and nitrate nitrogen parameters simultaneously
10Equipped with automatic detection function for electrode aging, the degree of electrode aging can be displayed through the offset of the characteristic curve
5TECHNICAL INDEX
|
model |
AmmoLyt®Plus 700 IQAmmonia nitrogen sensor |
NitraLyt®Plus 700 IQNitrous nitrogen sensor |
VARiON®Plus 700 IQAmmonia nitrogen/Nitrogen nitrate two in one sensor |
|
Optional electrode configuration |
Reference electrode:VARiON®Plus Ref |
Reference electrode:VARiON®Plus Ref |
Reference electrode: |
|
Ion compensation range/resolution |
1~1000 mg/L / 1 mg/Lpotassium ion |
1~1000 mg/L / 1 mg/LChloride ion |
1~1000 mg/L / 1 mg/Lpotassium ion |
|
Temperature measurement and compensation |
built-in NTCTemperature probe, Test range:- 5℃~+ 60℃Compensation range:0℃~+40℃Accuracy:±0.5℃Resolution:0.1℃, Response time:t 95 < 20 s |
||
|
material |
Protective cap:POMElectrode body and temperature probe:V4Astainless steel1.4571Electrode connector:POM |
||
|
protection grade |
IP68 |
||
|
pressure resistance |
0.2hope earnestly |
||
|
power |
0.2W |
||
|
accuracy |
±5%test value±0.2 mg/L |
||