Provide professional magnetic field measurement solutions | ||||||
Strong magnetic field measuring instrument(0 - 20T) | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
X113 |
hall |
hall sensor |
1 |
<> |
15T |
TC: 30ppm/K |
G80 |
hall |
handheld |
1 |
2% |
2T |
10μT |
G81 |
hall |
handheld |
1 |
0.8% |
10T |
1μT |
G82 |
hall |
handheld-high frequency |
1 |
0.8% |
10T |
1μT |
G83 |
hall |
handheld |
3 |
0.8% |
10T |
1μT |
G92 |
hall |
handheld |
1 |
1% |
10T |
10μT |
G93 |
hall |
handheld |
3 |
1%, 0.5% |
20T |
1μT |
G201 |
hall |
Desktop computer |
1 |
0.2% |
10T |
1μT |
G203 |
hall/reluctance |
Desktop computer |
3 |
0.2% |
10T |
10nT |
G401 |
hall |
Desktop computer |
1 |
0.04% |
10T |
1μT |
G403 |
hall |
Desktop computer |
3 |
0.04% |
10T |
1μT |
GSP301A |
hall |
Analog transmitter |
1 |
1%, 0.2% |
10T |
Output: ±3V |
GSP301D |
hall |
Digital transmitter |
1 |
1%, 0.2% |
10T |
1μT |
GSP303D |
hall |
Digital transmitter |
3 |
1%, 0.2% |
20T |
1μT |
GSP303D-S |
hall |
Digital transmitter |
3 |
0.5%, 0.1% |
3T |
1μT |
Magnetic field testing system | ||||||
GAS3000 |
Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location |
|||||
GMS980 |
High precision Gaussian meter calibration system (High precision Tesla meter calibration device) |
|||||
Weak magnetic field measuring instrument(0- 2mT) | ||||||
Weak magnetic field Gaussian meter | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
GMR61 |
reluctance |
handheld |
1 |
0.8% |
600μT |
10nT |
GMR63 |
reluctance |
handheld |
3 |
0.8% |
600μT |
10nT |
GF601 |
fluxgate |
handheld |
1 |
0.5% |
1mT |
0.1nT |
GF603 |
fluxgate |
handheld |
3 |
0.25% |
1mT |
0.1nT |
GF633 |
fluxgate |
Desktop computer |
3 |
0.1% |
100μT |
0.01nT |
GFP703 |
fluxgate |
Smart Transmitters |
3 |
0.5% |
1mT |
0.1nT |
GFP703S |
fluxgate |
Spectrum analyzer |
3 |
0.5% |
1mT |
0.01nT |
GFP803 |
fluxgate |
Smart Transmitters |
3 |
0.2% |
1mT |
0.1nT |
Communication magnetic field measurement(DC- 1MHz) | ||||||
model |
principle |
type |
number of axles |
ACaccuracy |
maximum range |
frequency response |
AMS-2K |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
30Hz- 2kHz |
AMS-1M |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
2kHz- 1MHz |
G1000 |
reluctance |
Smart Transmitters |
3 |
DC- 1% AC- 2% |
400μT/ Axis |
DC- 1MHz |
GA1000 |
reluctance |
handheld |
3 |
2% |
400μT/ Axis |
30Hz- 1MHz |
GSP301HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
GSP303HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
fluxgate sensor | ||||||
model |
principle |
type |
number of axles |
noise level |
maximum range |
output |
F901 |
fluxgate |
Economic type |
3 |
10 to 20pT |
1000μT |
±10V,single-ended |
F902 |
fluxgate |
low noise |
3 |
<> |
100μT |
±10V,single-ended |
F903 |
fluxgate |
low-power consumption |
3 |
10 to 20pT |
200μT |
±3V,finite difference |
F904 |
fluxgate |
low-power consumption|low noise |
3 |
<> |
100μT |
±3V,finite difference |
F905 |
fluxgate |
high-performance|low noise |
3 |
<> |
100μT |
±10V,single-ended |
F23 |
fluxgate |
split type|large range |
3 |
<> |
1500μT |
±10V,single-ended |
F53 |
fluxgate |
High temperature type |
3 |
≤ 300pT@175℃ |
100μT |
±5V,finite difference |
Magnetic flux gate sensor data acquisition unit | ||||||
FDU301 |
Connectable1A three-axis flux gate sensor |
|||||
ASA1000 |
Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor |
|||||
AFS |
Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters |
|||||
GMR-16 |
Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor |
|||||
GR100 |
Digital three-axis flux gate gradiometer |
|||||
remarks: 1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG 2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model |
sketch:
Kore Technology GmbH in Germany has many years of experience in magnetic field testing and has launchedGMR61Weak magnetic field one-dimensional Gaussian meter can be used for air cargo magnetic field detection, accurate detection of geomagnetic field, etc.3.2The inch color industrial touch screen provides rich display content and has the maximum value/minimum value/Maintain value/Alarm threshold, real-time magnetic field strength and other functions.
GMR61The probe thickness of a weak magnetic field one-dimensional Gaussian meter is only2.5mmThe width is only5.5mmIt is very suitable for research institutions, universities, and businesses to use.
GMR61Measurement range of weak magnetic field single dimensional Gaussian meter600μT, Resolution10nTThe single dimensional probe option with built-in temperature sensor has temperature compensation function, which can improve the accuracy and stability of measurement data when the temperature changes. Therefore, it is strongly recommended to purchase a probe with built-in temperature sensor.
GMR61Weak magnetic field one-dimensional Gaussian meter has been passedCECertification andEMC(electromagnetic compatibility)Testing.
characteristic | |
l Single dimensional magnetic field detection l Ergonomic design l Graphical interface operating system l 3.2inchLCDcolorful touch screen l Maximum value/minimum value/hold function l Intelligent recording and viewing l 4400mAHrechargeable battery |
l The probe thickness is only2.5mm l The probe width is only5.5mm l measuring range600uT l resolution10nT l DCAccuracy:0.8% l complete5Position display l Probe with temperature compensation function optional |
|
![]() |
GMR61Single dimensional weak magnetic field Gaussian meter parameters:
model |
GMR61 |
Measurement parameters | |
accuracy/axle(DC) |
±0.8% |
range |
600μT (6G) |
resolution |
10nT (0.1mG) |
Display digits |
5 |
Frequency response range[fT] |
DC - 80Hz |
Typical temperature coefficient |
<±500ppm>±500ppm>℃(Conventional single dimensional probe) <±100ppm>±100ppm>℃(Probe with built-in temperature sensor) |
front panel | |
display type |
3.2Inch color resistive touch screen,320x240pixel |
Display units |
Gaussian(G)Tesla(T) |
Display update rate |
3order/second |
display mode |
DC、ACMaximum value, minimum value, alarm, etc |
probe | |
Compatible probes |
details“Probe specifications”list |
Probe cable length |
standard1.5Rice; |
USBinterface | |
function |
1Communication interface: used for connectingPCMonitor and measure with Gaussian meter host; 2Charging interface: used for connectingPCOr a portable power bank(power bank)Charge the Gaussian meter host. |
software/drive |
Upper computer software, no need to install other drivers |
Host specifications | |
operation temperature |
+15℃to +35℃(accuracy rating) -10℃to +60℃(Reduced accuracy) |
storage temperature |
- 20℃to +60℃ |
Environmental magnetic field |
<> |
battery |
rechargeable4400mAHLithium Ion Battery |
Battery operating time |
>16Hour (standard test environment) |
size |
238 mmW× 95 mmH× 42 mmD |
weight |
350g |
qualification |
CECertificationEMCauthentication |
Probe specifications
![]() |
Single dimensional probe | |||||||
probe Type |
maximum range |
resolution |
Frequency response range |
Probe rod size (mm) |
operation temperature |
DCaccuracy (25℃) |
Probe rod material |
Axial magnetic field probe A08L150GMR61 A08L150GMR61T |
6G (600μT) |
0.1mG (10nT) |
DC -80Hz |
60*5.5*2.5 |
-20℃- +60℃ |
±0.8% |
plastics |
Radial magnetic field probe T08L150GMR61 T08L150GMR61T |
6G (600μT) |
0.1mG (10nT) |
DC -80Hz |
60*5.5*2.5 |
-20℃- +60℃ |
±0.8% |
plastics |
Note:
1The model contains letters at the end“T”Probe with built-in temperature sensor, equipped with temperature compensation function, and its temperature coefficient<±100ppm>±100ppm>℃;
2Sensor center position and three-axis direction:
Probe selection type description
T |
08 |
P |
150 |
GMR61 |
T |
probe Type A -Axial probe T -radial probe X - 2 AXIS Y - 3 AXIS
|
Probe length 06 - 6 cm 08 - 8 cm 10 - 10 cm 25 - 25 cm
… |
Probe style C – CRYOGENIC F – FLEXIBLE H – HIGH TEMP. L – LOW FIELD M – METAL P – PLASTIC U – ULTRATHIN W – WIDE FIELD |
Probe cable length 150 – 150cm 300 – 300cm 500 – 500cm
… |
Gaussian meter type GMR61 – GMR61 probe
|
Temperature compensation function (Probe with built-in temperature sensor)
T -have BLANK -not have |