performance
|
advantage
|
|
run time
|
At least 2600 hours of continuous operation, powered by a replaceable CR2 lithium battery.
|
|
|
|
|
display
|
Users can configure the display screen to display real-time readings directly (in ppm or% content) (O2)Or only display the gas type.
|
|
|
|
|
Display Size
|
The direct gas reading display screen is the largest and most visible display screen used in single gas detection instruments. Icons make the user interface simple and refreshing, making it easy to understand around the world.
|
|
|
|
|
Time weighted average (TWA) and short-term exposure limit (STEL)
|
The current viewing function for TWA and STEL values is GasBadge®Pro standard configuration.
|
|
|
|
|
TWAThe STEL alarm can be adjusted by the user themselves.
|
The Time Weighted Average (TWA) and Short Term Exposure Limit (STEL) alarms can be adjusted by the user to ensure that the device will enter an alarm state when the customized set point is exceeded, prompting the user of the alarm situation that has occurred.
|
|
|
|
|
data record
|
Standard one-year (minimum) data recording energy (the largest memory in the industry).
|
|
|
|
|
Adjustable data recording interval
|
The adjustable recording interval allows users to choose the frequency at which the instrument records information.
|
|
|
|
|
GasBadge ®Connection
|
The GasBadge data link is an optional accessory that enables instant download of alarm events, instrument details, and hygiene data to a computer (via USB connection).
|
|
|
|
|
Compatible with DS2 Docking Station ™
|
The DS2 Docking Station is a GasBadge®Optional accessories for Pro. The independent instrument docking station (IDS) provides automatic instrument calibration, data maintenance, diagnosis, and data download functions. Utilize a central database to store all information for archiving or printing purposes. Up to 100 IDS modules can be linked - thousands of instruments can be connected.
|
|
|
|
|
DISPLAY BACKLIGHT
|
Users only need to press the button to view the current gas reading in low light environments. When an alarm condition occurs, the backlight will flash as an alert, serving as another way to indicate the existence of a dangerous situation.
|
|
|
|
|
Four key operation
|
Users can easily configure the instrument. GasBadge Pro provides the most convenient user selection for any single gas detection instrument.
|
|
|
|
|
Sensor options
|
Interchangeable "smart" sensors can monitor oxygen or any of the following toxic gases: CO, H2S, O2, NO2, SO2, Cl2, ClO2, PH3, NH3, H2, CO/H2 (zero) and more.
|
|
|
|
|
waterproof
|
GasBadge®Pro has waterproof function, ensuring that the device can be protected from outdoor environmental conditions, such as rain, water mist formed during flushing, and other harsh industry applications. Its design complies with IP67
|
|
|
|
|
Event record
|
GasBadge®Pro will continuously record the last 15 alarm events. When the event recorder is full, it will automatically overwrite old records with a write.
|
|
|
|
|
Infrared printing interface
|
The infrared interface allows the device to easily print event records to POS printers with infrared ports.
|
|
|
|
|
The alarm can be adjusted by the user themselves
|
The setting points for low-level and high-level alarms can be fully adjusted by users themselves. This enables users to set instrument alarm functions according to their own enterprise standards.
|
|
|
|
|
Top plug-in sensor
|
Even when placed in a shirt pocket, it can provide continuous and uninterrupted protection.
|
|
|
|
|
Sensor over range protection function
|
Ensure that the sensor is protected when exposed to high concentrations of gas. When an over range situation occurs, the instrument will prompt the user with "OR".
|
|
|
|
|
Powerful auditory alarm device with vibration and visual alarm functions (standard configuration).
|
Standard high pitched (95 decibels) auditory alarm; Ultra bright visual alarm display, visible from any direction; If there is a dangerous state, a vibration alarm will be triggered to alert the user.
|
|
|
|
|
Small size (3.7 x 2 x 1.1 inches) (94 mm x 50.8 mm x 27.9 mm)
|
Compact structure, can be fastened to the body with various fixtures, without affecting comfort; Or it can be placed in the front pocket of the shirt. Top plug sensors will not be obscured by pockets and affect performance.
|
|
|
|
|
Lightweight -3.0 ounces (85 grams)
|
This device weighs only 3.0 ounces (85 grams) and can be comfortably worn on any part of the body.
|
|
|
|
|
Anti vibration protective shell
|
The protective rubber filling makes the equipment extremely durable and easy to handle.
|
|
|
|
|
Peak detection
|
The instrument can continuously detect while maintaining visibility of the highest gas reading (the gas that the sensor has been in contact with since the last peak clearance) within the site.
|
|
|
|
|
Recent calibration indication
|
The 'Last Calibration Time' function allows end users to view the number of days since the last calibration.
|
|
|
|
|
Lifespan indicator
|
GasBadge®Pro can continuously monitor and display the remaining lifespan of the instrument until it becomes completely inoperable.
|
|
|
|
|
staple bolt
|
Each GasBadge set®Pro comes with a belt clip and spring clip (standard configuration). Other accessories such as handling boxes and fire ropes are also available for purchase.
|
|
|
|
|
Anti electromagnetic interference (EMI)/anti radio frequency interference (RFI)
|
External radio frequency interference from mobile phones, handheld wireless devices, and other electronic devices will not cause false alarms.
|
|
|
|
|
Self Test
|
The automatic self-test function ensures the correct operation of instruments, sensors, and circuits. Users can initiate auxiliary function testing to ensure the proper functioning of the alarm function.
|
|
|
|
|
End of Life Warning
|
When the battery life is seven days left, the empty battery icon will emit a flashing alarm, indicating to the user that the device's life is about to end. When there are only four hours left in the lifespan, users will receive an urgent alarm prompt every 15 seconds and the empty battery icon will flash. Both types of alarms are advance notifications to users: please replace the device.
|
|
|
|
|
Continuous operational performance
|
The 'normally on' performance allows end users to set the instrument to an on-site mode that cannot be turned off. In this way, the instrument can continue to operate until the battery is depleted.
|
|
|
|
|
Calibration overdue indication
|
This feature allows users to set alarm indicators to alert end users that the instrument needs to be calibrated.
|
|
|
|
|
Shell:
|
Durable and sturdy, with a waterproof polycarbonate shell and protective rubber filling. Prevent radio frequency interference.
|
|
Size:
|
3.7 x 2 x 1.1 inches (94 mm x 50.8 mm x 27.9 mm)
|
|
Weight:
|
3 oz. (85 grams)
|
|
Range:
|
|
gas
|
chemical formula
|
range
|
resolution
|
|
carbon monoxide
|
CO
|
0-1,500
|
1 ppm
|
|
hydrogen sulfide
|
H2S
|
0-500ppm
|
0.1 ppm
|
|
oxygen
|
O2
|
Volume ratio 0-30%
|
0.1%
|
|
nitrogen dioxide
|
NO2
|
0-150ppm
|
0.1 ppm
|
|
sulfur dioxide
|
SO2
|
0-150ppm
|
0.1 ppm
|
|
ammonia
|
NH3
|
0-500ppm
|
1 ppm
|
|
chlorine
|
Cl2
|
0-100ppm
|
0.1 ppm
|
|
chlorine dioxide
|
ClO2
|
0-1ppm
|
0.01 ppm
|
|
hydrogen cyanide
|
PH3
|
0-10ppm
|
0.01 ppm
|
|
hydrogen cyanide
|
HCN
|
0-30ppm
|
0.1 ppm
|
|
hydrogen
|
H2
|
0-2,000ppm
|
1 ppm
|
|
|
display:
|
Customized LCD display with icon display, simple and easy to use. Segmented display of direct gas readings. Suitable for backlight function in low light environments. Continue/Do not continue "display mode. Leakage reading indication.
|
|
call the police:
|
User selectable low/high alarm device. Ultra bright indicator light, loud auditory alarm device (95 decibels), and vibration alarm device.
|
|
Battery (running time):
|
User replaceable 3V, CR2 lithium battery Normally, the running time can reach 2600 hours (minimum)
|
|
Event record:
|
Continuously running. Record the last 15 alarm events, including their occurrence time, duration, and visible gas concentration during the event. Event records can be viewed on a computer or directly transmitted from the instrument to an infrared printer for printing.
|
|
Data recording:
|
One year, with an interval of one minute
|
|
Temperature range:
|
Normally: -40 º to 60 º C (-40 º to 140 º F)
|
|
Humidity range:
|
Normally: 0-99% RH (non condensing)
|
|
authentication:
|
UL and cUL: -Grade I, Class 1, A. B, C, D groups; T4 -Level I, Zone 0, AEx ia IIC T4 CSA: -Grade I, Class 1, A. B, C, D groups; T4 - EEx ia IIC T4 ATEX: -Intrinsic safety: Safety: EEx ia I/IIC T4 -Equipment group and category: II 1G; I M2 -Electromagnetic compatibility (EMC): EN50270
Performance: O2(EN50104); CO, H2S. (EN45544) (TBD) Australia: Ex ia I/IIC T4 IEC: Ex ia IIC T4 Russia: GOST-R certification (to be determined)
|