SH103The trace moisture analyzer is based on the Karl Fischer Coulomb titration principle,Adopting microcomputer automatic control, compared with similar advanced products at home and abroad, it has the advantages of high sensitivity, fast electrolysis speed, short equilibrium time, accurate blank deduction, and reliable analysis results. It is the preferred high-quality analytical instrument for departments such as petroleum, chemical, power, environmental protection, medicine, and scientific research. The instrument adopts32Embedded microprocessor as the main control core, embedded in a mini operating system; The instrument comes with constant current detection and dual circuit balanced titration functions; The electrolytic cell adopts the latest waterproof sealing design; Support multiple calculation formulas.
Technical Specifications:
The Karl Fischer Coulombic method is the most reliable method for determining trace amounts of moisture in different substances and is in line withGB/T11133This micro moisture analyzer has successfully applied this method and adopted microcomputer control. It has fast analysis speed, high accuracy, LCD screen Chinese display, automatic printing, and dual functionsCPUDesign, automatic blank current deduction function, instrument fault self diagnosis, menu selection and other functions to achieve better operation and use, with a simple operation and fully automatic analytical instrument. It is the most ideal instrument for analyzing the moisture content of oil products
Display mode: Color touch screen display
Titration method: microcomputer controlled electrical titration
output method:automatic calculation,Capable of outputtingugThePPMand%
Measurement range: as a percentage0.00001%to100%, pressPPMIt can be said that0.1ppmUp to one millionppm
divide distinguish Rate:0.1ug
Electrolysis control: automatic electrolysis current tracking control (maximum)400mA)
Titration speed:2.5mg/min(maximum)
Sensitivity:0.1ug---100gnot greater than2% 1mgThe above is converted into0.3%(Excluding injection errors)
printer:16Character needle printing paper width44millimeter
electricity Source: Communication220V±10% 50Hz±10%
merit Rate:60VA
Environmental temperature for use:5-40~C
Operating environment temperature: ≤90%
Required consumables: Special Karl Fischer reagent, the instrument itself comes with a set of reagents, which can be purchased or self equipped after use.
DL/T 915-05,GB 5832-1986
Meet the following standards:
1TheGB/T7600Method for determination of moisture content in transformer oil during operation(Coulomb's method)
2How to translateThe
3GB6283Determination of Moisture Content in Chemical Products by Karl Fischer Method (General Method)The
4SH/T0246Determination of Water Content in Light Petroleum Products (Electricity Method)The
5SH/T0255Method for determination of moisture content in additives and lubricating oils containing additives (electric method)The
6GB/T11133Method for determination of water content in liquid petroleum products (Karl Fischer method)The
7GB/T7380Determination of Water Content in Surfactants (Karl Fischer Method)The
8GB10670Determination of Trace Moisture in Fluorinated Methanes for Industrial Use by Karl Fischer MethodThe
9GB/T606Chemical reagents General method for determination of moisture Karl Fischer methodThe
10GB/T8350Denaturated Fuel EthanolThe
11GB/T8351Ethanol gasoline for vehiclesThe
12GB/T3776.1Method for determination of moisture content of pesticide emulsifiersThe
13GB/T6023Determination of Trace Moisture in Industrial Butadiene by Karl Fischer Coulombic MethodThe
14GB/T3727Determination of trace water in industrial ethylene and propyleneThe
15GB/T7376Determination of Trace Moisture in Fluorinated Alkanes for Industrial UseTheGB/T18619.1Determination of water content in natural gas by Karl Fischer method
16-Coulomb's methodThe
17GB/T512Method for determination of moisture content in lubricating greaseThe
18GB/T1600-Method for determination of pesticide moisture contentThe
19GB/T11146Determination of Water Content in Crude Oil by Karl Fischer Coulombic MethodThe
20GB/T12717Test Methods for Acetic Esters for Industrial UseThe
21GB/T5074Method for determination of moisture content in coking productsTheGB/T18826industrial use1,1,2-
Tetrafluoroethane(
|
HFC-134a) |
List of lubricating oil and grease analysis instruments |
Instrument name |
Instrument model |
|
Instrument name |
Instrument model |
Semi automatic open flash point tester |
SD3536 |
|
Automatic rotating oxygen bomb analyzer |
SH0913B |
Fully automatic open flash point tester |
SH107B |
|
Lubricating grease dropper |
SD4929 |
Semi automatic kinematic viscometer |
SD265 |
|
Wide temperature drop point meter |
SH117 |
Automatic kinematic viscometer |
SH112 |
|
Automatic Wide Temperature Drop Point Meter |
SH3498 Pour point analyzer |
SD510 |
Oil bath |
|
penetrometer |
SD2801Pour point analyzer |
SH113B |
metal bath |
|
100000 times shearing machine |
SH269 |
Automatic pour point meter |
SH113 |
|
Drum stability tester |
SH129 |
Petroleum demulsifier |
SD7305 |
|
Lubricating grease evaporation loss meter |
SY7325 |
Automatic petroleum demulsifier |
SH122 |
|
Lubricating grease copper corrosion tester |
SY7326 |
Copper corrosion tester for petroleum products |
SD5096 |
|
Lubricating grease oxidation stability tester |
SH0325 |
Lubricating oil moisture meter |
SH103 |
|
Lubricating grease similarity viscosity meter |
SH0048 |
Automatic lubrication oleic acid value meter |
SH108 |
|
Mechanical impurity level of lubricating grease |
SY0336 |
Foam instrument for petroleum products |
SH126 |
|
Lubricating grease leakage meter |
SY0326 |
Lubricating oil evaporation loss meter |
SH0059 |
|
Automatic Friction and Wear Tester |
SH120 |
Oil air release value meter |
SH0308 |
|
Automatic grease moisture meter |
SH103B |
Lubricating oil apparent viscosity meter |
SH110 |
|
Lubricating grease adhesion tester |
SH127 |
Engine oil pump temperature gauge |
SH9171 |
|
Steel mesh oil separator |
SH12 |
Oil particle counter |
SH302 |