Ethylene gas analyzer F-960 can quickly measure C2H4、 CO2、 O2Assist in monitoring the ripening process of fruits and vegetables.
|
![]() |
||||||||
|
major function |
![]() |
||||||||
|
Ø Measurable C2H4、 CO2、 O2 Ø Measurement response time:<30 seconds Ø Historical measurement data can be accessed at any time Ø Handheld design, compact and lightweight Ø 4GSD card data storage Ø Battery life: 8h |
|||||||||
|
Measurement parameters |
|||||||||
Ethylene, carbon dioxide, and oxygen concentrations, date, time, humidity, temperature, GPS positioning data |
|||||||||
|
application area |
|||||||||
|
Ø Quality assurance of banana ripening process Ø Optimization of storage environment during ripening process Ø Testing the degree of food ripening during bagging and packaging processes Ø Storage allocation in distribution centers Ø Detection of ripening gas leakage |
|||||||||
Main technical parameters |
|||||||||
|
Ø Intake speed: 70 mL/min Ø Measurement speed: open or closed circuit measurement, automatically saved every 1 second, capable of storing tens of thousands of sets of data Ø Display: Visible LCD screen under light Ø Operating environment: 0-45 ℃ (relative humidity 0-90%, no dew point) Ø Size: 18cm × 13.5cm × 5.5cm Ø Weight: 0.95kg Ø Shell: Aluminum alloy shell Ø Power supply: portable, rechargeable battery Ø Computer interface: USB interface and SD card or Wi Fi Ø Data Record: C2H4Concentration CO2Concentration O2Concentration, date, time, relative humidity, GPS data |
|||||||||
| Ethylene sensor | |||||||||
|
Ø Sensor type: Electrochemical detector Ø Measurement range: 0-500ppm Ø Resolution: 1ppm Ø Accuracy: ± 5% of measured value Ø Minimum detection limit: 10ppm Ø Zero point calibration: daily Ø Span calibration: 3 months Ø Service life: 12 months |
|||||||||
| CO2sensor | |||||||||
|
Ø Sensor type: Infrared thermoelectric sensor Ø Measurement range: 0-100% Ø Resolution: 0.01% absolute concentration Ø Accuracy: ± 1% absolute concentration, ± 3% measured value Ø Air intake time: 6 seconds Ø Calibration: Annual Ø Service life:>5 years |
|||||||||
| O2 sensor | |||||||||
|
Ø Sensor type: Electrochemical detector Ø Measurement range: 0-100% Ø Resolution: 0.1% absolute concentration Ø Accuracy: ± 0.25% absolute concentration, ± 2% measured value Ø Air intake time: 6 seconds Ø Calibration: 6 months Ø Service life: 12 months |
|||||||||
|
Purchase Guide |
|||||||||
| Host, manual, related accessories, and box | |||||||||
| Origin:Felix from the United States | |||||||||