1.Electronic components thermal shock high and low temperature aging test chamberDetailed parameters:
|
Two box thermal shock test chamber Divided into two parts: high temperature zone and low temperature zone, the test sample is placed in one of the working rooms and passed throughhas-beenRealize the switching of samples between high and low greenhouses through dynamic mode, and complete the cold and hot temperature shock test. The unique heat and cold storage structure ensures good constant temperature performance of the test chamber. |
|
COK-50-2H Note: The air-cooled type does not require the installation of a cooling tower, while the water-cooled type requires installation, depending on customer requirements. |
|
This experimental equipment prohibits: ① Testing or storage of samples of flammable and volatile substances ② Testing or storage of corrosive substance samples ③ Testing or storage of biological samples ④ Testing or storage of strong electromagnetic emission source samples |
| |
Nominal internal volume |
150L |
Basket size |
W500*H600*D500mm |
outsideboxsize |
W1800*H1900*D1540mm |
shock temperature |
-40℃~150℃ |
| |
|
Under the conditions of an ambient temperature of+25 ℃, relative humidity ≤ 85%, and no sample in the test chamber GB/T 5170.2-1996 Temperature testing equipment. |
|
|
5.3.1. High temperature chamber |
+60℃→+180℃ |
5.3.2.riseWarm speed |
Heating up+60 ℃ →+180℃ ≤25min Note: The heating time refers to the performance of the high-temperature chamber when operated separately |
Low temperature testing area |
|
5.4.1.temperature range |
-55℃~-10℃ |
5.4.2. Cooling rate |
cool down-10℃ → -55℃≤35min Note: The cooling time refers to the performance when the low-temperature chamber is operated separately |
Test method |
|
5.5.1.Test method |
The test basket switches the sample between high temperature and low humidity testing zones through pneumatic means. |
5.5.2.thermal shockFanenclose |
(+50~+150)℃/(-40~-10)℃ |
5.5.3.temperature fluctuation |
±0.5℃ |
5.5.4.temperature deviation |
±2.0℃ |
5.5.5.Temperature recovery room |
≤3~5min |
5.5.6Temperature conversion room |
≤10sec |
5.5.7.Test function |
It can independently set three different conditions of high temperature, low temperature, and thermal shock, and has the function of a high and low temperature alternating test chamber. |
|
GB/T 2423.1-2008 Test A: Low temperature test method GB/T 2423.2-2008 Test B: High temperature test method GB/T2423.22-2002 Test N: Temperature change test method Test Na GJB 150.5A-2009 Military Equipment Laboratory Environmental Test Methods Part 5: Temperature Shock Test GJB 360A-1996 Temperature Shock Test GJB367.2-2001 General specification for military communication equipment - Temperature shock test IEC 68-2-14test methodN: Temperature variation |

2.Electronic components thermal shock high and low temperature aging test chamberStructure:
1、 High temperature chamber
Heater: Nickel chromium alloy electric heater
Fan: shared centrifugal fan for high temperature and environmental temperature exposure, axial flow fan for preheating
2、 Low temperature chamber
Heater and cooler: Nickel chromium alloy electric heating, finned cooler, and cold storage device
Fan: Centrifugal fan
3、 Drive device
Pneumatic cylinder: used for driving various dampers during high temperature, ambient temperature, and low temperature exposure
Air Compressor: Provides compressed air to drive pneumatic dampers (optional)
4、 Refrigeration unit
Refrigeration method: mechanical compression binary cascade refrigeration
Refrigeration compressor: semi enclosed piston type
Refrigerant: 23/R404 environmentally friendly
Condenser: Stainless steel brazed plate heat exchanger
5、 Controller
Operation interface: 6 'color LCD display touch screen, Chinese menu prompts
Program memory capacity: 100 sets of user programs (customizable and modifiable)
Set indicator range: time: 1 minute~99 hours and 59 minutes, cycle: 1~999 cycles
Resolution: Temperature: 0.01 ℃, Time: 1 minute
Input: T-type thermocouple
Control method: PID control
Auxiliary functions: timer, over temperature protection, sensor up and down wind selection, power outage protection, alarm recording, test curve recording, test pause, program running time display
Power supply: AC380 ± 10% V 50 ± 0.5Hz, three-phase four wire+protective ground wire
Power (kw): 20, 21, 22
Cooling circulating water: water pressure: 0.2~0.4MPa, water temperature: ≤ 30 ℃
Compressed air: 0.5~0.7MPa
Standard configuration: Test chamber status indicator light, 1 timer, 1 lead hole (25 × 100mm elongated hole on the left side of the box),imperial son-in-law6 casters, 4 adjustable feet