Chengdu Fokker Instrument Co., Ltd
Home>Products>Electromagnetic wave tester (Gauss meter) LUTRONEMF827
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18113005055
  • Address
    13th Floor, Building C, Renhe Spring Plaza, No. 19 West Section 2, Second Ring Road, Chengdu City
Contact Now
Electromagnetic wave tester (Gauss meter) LUTRONEMF827
LUTRONEMF827 Electromagnetic Wave Tester (Gauss Meter) is used to reliably and quickly measure the electromagnetic radiation emitted by wires, househo
Product details

LUTRONEMF827 Electromagnetic Wave Tester (Gauss Meter)

1. Characteristics of Electromagnetic Wave Tester LUTRONEMF827:
Testers are used to reliably and quickly measure the electromagnetic radiation emitted by wires, household appliances, and industrial equipment.
3-segment wide range 20mTesla, 200mTesla, 2000mTesla,
2. Application:
Used to detect electromagnetic radiation emitted by electrical wires, computer monitors, televisions, video equipment, and other devices.
3. Electromagnetic exposure warning
According to scientists, long-term exposure to electromagnetic radiation may lead to sepsis or other forms of cancer in children The complete answer to such questions has not yet been obtained, and the general approach is to avoid them as much as possible.

Technical parameters:

display

13mm3 1/2Digital display, * large199.9

range/analysis

20uTesla /0.01 uTesla

200uTesla /0.1 uTesla

2000uTesla /1uTesla

bandwidth

30Hz300Hz

number of axles

uniaxial

accuracy

±(4%+3d- 20uTesla

±(5%+3d- 200uTesla

±(10%+5d)2000uTesla
Accuracy measurement in50Hzperhaps60Hz

Over range indication

Display“1

sample time

0.4second

battery

DC 9V

Power supply current

DC 2mA

operate temperature

0-50

Operating humidity

*Big90%0-35℃) * large80%35-50℃)

weight

TN-2823215g(including battery)
TN-2827
285g(including battery)

size

HWD - 163×68×24mm
Probe (limited to)TN-2827

175
×45×22mm

attachment

user's manual1PC

*TN-2823giveTN-2827Main differences:
TN-2827
Having an independent probe for measurement is more convenient,TN02823Use built-in probe, other parameters are the same.

Measurement steps:

1)Will 'Off/Range”Turn the switch to the corresponding position, select the highest gear for unknown measurement situations, and then lower it to achieve high accuracy.
Due to electromagnetic interference in the environment, it is normal for the instrument to display small values before measurement.
2
)Slowly move the handheld instrument towards the object being measured until it touches the object being measured.
Note that the reading increases when you move
3
)Point the instrument at the measured object at different angles and observe the changes in readings.
4
)Try measuring from different angles and record the maximum value.
If the power supply of the measured object is turned off during the measurement process, the reading of the tester will return to“0”.
5
)The measurement unit of the instrument is microtesla(microTesla)If you want to know about Gauss(mili Gauss)The value, please multiply the reading by“10”.

Suggestion:


Regularly monitor the electromagnetic radiation inside and outside your living room. If strong radiation points are found, please relocate the environment.

Battery replacement:


When“LO BAT”Displayed inLCDWhen in the upper left corner, it indicates that the battery voltage is between6.5V~7.5VAt this point, the battery needs to be replaced. However, the battery can still be used for a few hours afterwards. Remove the battery back cover and replace it with a new one9VBattery. Put the lid back on.


Related products:YS-2499A series dual channel pulse waveform displayPeak microwave power meter (dual channel pulse high-power meter);GX2BBSeries microwave power meter (RF power meter);YS1125 (B) microwave signal source (RF signal generator); YS3892 frequency selective amplifier; PXSeries microwave frequency meter (RF frequency meter);3cm10cm)Waveguide testing system;FYS3000Complete set of waveguide testing system accessories;TC26Three centimeter waveguide measurement line;RCQ1AMicrowave leakage energy tester;SHK-4(3)Variable RF attenuator;BSeries fixed RF attenuator;YTJ8-3YTJ8-4YTJ8-5 seriesSMAJoint coaxial crystal RF detector; TJ8-4, TJ8-3, TJ8-5, TJ8-2 series coaxial crystal RF detectors, with optional British (N-type) or metric (L16) connector types; TTK-2/4Series RF coaxial switch;FYDTT)Series RF directional coupler;YSDTZ)Series microwave load;FYS(BD)Series waveguide components, etc



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!