Used for rapid in-situ detection and monitoring analysis of hydrocarbons and organic pollution in soil and air, capable of simultaneously measuring methane, petroleum hydrocarbonsCO2、O2、 Atmospheric pressure, sampling low pressure, soil temperature, etc., combined with GPS (Global Positioning System), can easily draw the 3D spatiotemporal distribution of pollutants. Built in computer, display screen, vacuum sampling pump, and battery. Widely used in soil pollution investigation and monitoring, oil spill detection, landfill and agricultural waste pollution monitoring, pollution control monitoring, coal mine gas detection, air pollution monitoring, and so on.
ECOPROBE 5 is combinedschedulePID lightToIonization analysistechnology(Used for testing)VOCs and other toxic gases such as chlorinated hydrocarbons)and4通道selectivityIR infrared analysistechnology(Measure methane, petroleum hydrocarbons, and carbon dioxide separately), another reference channel)The sampling frequency reaches every second10 times, with an accuracy of ppb level.
Main performance indicators
PID analyzerDetecting volatile organic compounds(VOCs and other toxic gases such as chlorinated hydrocarbons
1. Two-way measurement limit range, standard range0.1ppm-4000ppm, Ultra sensitivity range of 0.1ppb to 100ppm
2. Response time:0.08Seconds, sampling rate:10A sample/second
3. built-in200Quantitative gas-phase automatic calibration of compounds
4. Ppb level resolution, large-scale dynamic measurement (0.1)ppb-4000ppm)
5. ppmormg/m3(ppborμg/m3)Output
IR analyzer:3An independent channel(Including a reference channel)Selective analysis and measurement of methane, petroleum hydrocarbons, andCO2
1. Methane:0 -500 000 ppm,Detection limit:20ppm
2. Petroleum hydrocarbons:0-500 000 ppm,Detection limit:20ppm
3. carbon dioxide:0-500 000 ppm,Detection limit:20ppm
4. Response time:0.5Seconds, sampling rate:10sample/second
5. ppmormg/m3output
Other readings:
·Oxygen:0-100 %
·Soil temperature: Fahrenheit,Celsius; (±0.1℃, resolution 0.01 ℃),
·Sample gas temperature: Fahrenheit,Celsius
·Environmental pressure/Sample vacuum degree,accuracy0.1%, resolution0.01%
Other performance indicators:
·size105 x 260 x 170 mm (Including handle),heavy3 Kilograms,Shipping weight of 13 kilograms (including soil gas sampling, calibration, attachments)
·power supply:Build in rechargeable battery
·memoryabout100000Secondary measurement value
dataoutput:RS232Data cable or infrared interface
·data formatASCII, EXCEL, GRAPHER, SURFERAnd user-defined formats
·display:Panoramic backlit LCD display screen
·keyboard input:Multi functional sealing key
·operating system:compatiblewin9x/NT4.0/2000/xp
·built-inThin film vacuum pumpAdjustable speed0.25-4rise/divide
Place of OriginEurope