Product Features
EDA9033F measuring instrument is an intelligent three-phase electrical parameter comprehensive acquisition measuring instrument; The three meter method accurately measures and displays electrical parameters such as three-phase voltage, three-phase current (true RMS), active power, reactive power, power factor, frequency, positive and negative active energy, and positive and negative reactive energy in three-phase three wire or three-phase four wire AC circuits on site through LED display. And it comes with 2 switch inputs and 1 adjustable relay alarm output. Its input is three-phase voltage (0-500V) and three-phase current (0-10A); Output digital signals as RS-485 or RS-232 interfaces, supporting communication protocols including MODBUS-RTU standard protocol, MODBUS-ASCII protocol, ASCII code communication protocol, and hexadecimal LC-04 protocol. The EDA9033F measuring instrument can be widely used in various industrial control and measurement systems, as well as various distributed/distributed power monitoring systems.
PRODUCT FUNCTION
Measure and display the three-phase phase voltages Ua, Ub, Uc; Three phase currents Ia, Ib, Ic; Active power P, reactive power Q, power factor PF, frequency f, active power Pa, Pb, Pc of each phase; Reactive power of each phase Qa, Qb, Qc; Positive active energy, reverse active energy, positive reactive energy, reverse reactive energy and other electrical parameters. Three rows of 4-digit LED displays and one row of 8-bit LED displays display various measurement data and setting parameters.
● Input signal
Three phase AC 50/60Hz voltage and current. Input frequency: 45-75Hz.
Voltage range (phase voltage): 10V, 60V, 100V, 250V, 400V, etc. are optional.
Current range: 1A, 2A, 5A, 10A, etc. are optional.
Signal processing: 16 bit A/D conversion, 6 channels, synchronous AC sampling at 4KHz rate per channel, real-time data
The update cycle can be set (100mS~1000ms, with 100mS per step);
Overload capacity: 1.4 times the range input can be measured correctly; Instantaneous (10 cycles) current 5 times, voltage 3 times range not available
Damaged.
● Input impedance: Voltage channel ≥ 1 k Ω/V; Current channel ≤ 50m Ω;
Switching input: 2-channel, passive null contact or logic level input, 0-0.5V or short circuited to 0,+5-30V
Or open circuit is 1; Communication output
● Output interface: RS-485 two-wire system+15KV ESD protection, or RS-232 two-wire system+2KV ESD protection
Protect.
● Communication speed (Bps): 1200, 2400, 4800, 9600, 19.2K, adjustable;
● Communication Protocol: Multiple protocols can be set: MODBUS-RTU standard protocol, MODBUS-ASC protocol, ASCII code communication protocol, hexadecimal LC-04 protocol.
● Relay output: 1 adjustable relay alarm output or remote control output, with a contact capacity of 250V/3A;
● Power supply for measuring instrument: AC220V; Power consumption:<2W
● Instrument specifications
Dimensions: 96mm * 96mm * 130mm Hole size: 90 * 90mm
● work environment
Working temperature: -20 ℃~70 ℃ Storage temperature: -40 ℃~85 ℃ Relative humidity: -5%~95% Non condensing
External dimensions