Shandong Lichuang Technology Co., Ltd
Home>Products>EDA9033F Three phase Integrated Power Monitoring Instrument
EDA9033F Three phase Integrated Power Monitoring Instrument
EDA9033F Three phase Integrated Power Monitoring Instrument
Product details

Product Features

EDA9033F measuring instrument is an intelligent three-phase electrical parameter comprehensive acquisition measuring instrument; The three meter method accurately measures and displays electrical parameters such as three-phase voltage, three-phase current (true RMS), active power, reactive power, power factor, frequency, positive and negative active energy, and positive and negative reactive energy in three-phase three wire or three-phase four wire AC circuits on site through LED display. And it comes with 2 switch inputs and 1 adjustable relay alarm output. Its input is three-phase voltage (0-500V) and three-phase current (0-10A); Output digital signals as RS-485 or RS-232 interfaces, supporting communication protocols including MODBUS-RTU standard protocol, MODBUS-ASCII protocol, ASCII code communication protocol, and hexadecimal LC-04 protocol. The EDA9033F measuring instrument can be widely used in various industrial control and measurement systems, as well as various distributed/distributed power monitoring systems.

PRODUCT FUNCTION

Measure and display the three-phase phase voltages Ua, Ub, Uc; Three phase currents Ia, Ib, Ic; Active power P, reactive power Q, power factor PF, frequency f, active power Pa, Pb, Pc of each phase; Reactive power of each phase Qa, Qb, Qc; Positive active energy, reverse active energy, positive reactive energy, reverse reactive energy and other electrical parameters. Three rows of 4-digit LED displays and one row of 8-bit LED displays display various measurement data and setting parameters.
Input signal
Three phase AC 50/60Hz voltage and current. Input frequency: 45-75Hz.
Voltage range (phase voltage): 10V, 60V, 100V, 250V, 400V, etc. are optional.
Current range: 1A, 2A, 5A, 10A, etc. are optional.
Signal processing: 16 bit A/D conversion, 6 channels, synchronous AC sampling at 4KHz rate per channel, real-time data
The update cycle can be set (100mS~1000ms, with 100mS per step);
Overload capacity: 1.4 times the range input can be measured correctly; Instantaneous (10 cycles) current 5 times, voltage 3 times range not available
Damaged.
Input impedance: Voltage channel ≥ 1 k Ω/V; Current channel ≤ 50m Ω;
Switching input: 2-channel, passive null contact or logic level input, 0-0.5V or short circuited to 0,+5-30V
Or open circuit is 1; Communication output
Output interface: RS-485 two-wire system+15KV ESD protection, or RS-232 two-wire system+2KV ESD protection
Protect.
Communication speed (Bps): 1200, 2400, 4800, 9600, 19.2K, adjustable;
Communication Protocol: Multiple protocols can be set: MODBUS-RTU standard protocol, MODBUS-ASC protocol, ASCII code communication protocol, hexadecimal LC-04 protocol.
Relay output: 1 adjustable relay alarm output or remote control output, with a contact capacity of 250V/3A; 

Power supply for measuring instrument: AC220V; Power consumption:<2W

Instrument specifications
Dimensions: 96mm * 96mm * 130mm Hole size: 90 * 90mm
work environment
Working temperature: -20 ℃~70 ℃ Storage temperature: -40 ℃~85 ℃ Relative humidity: -5%~95% Non condensing

External dimensions

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!