Survey chromatography workstation (pharmacopoeia specific workstation)
Drug GMP certified chromatographic workstation

Software/Workstation Features:
This workstation is a multi-channel, multi language, multi-user, multi project, and multi form 24 bit high-precision chromatographic signal acquisition and control software that can be used on Win7, Win8, 32-bit, and 64 bit operating systems. It is compatible with various mainstream software AIA spectrum formats for processing. The software fully complies with GLP/GMP, ISO9001, 21 CFR Part II, 2015 Pharmacopoeia and CTD format requirements, fully matches chromatographic column information, user management, permission settings, electronic signatures and batch processing, system adaptability evaluation (SST) and other audit tracking functions.
The fully Chinese operating interface, with function key settings and operation procedures that conform to Chinese usage habits, is more suitable for Chinese users compared to chromatography workstations with equivalent performance abroad.
In addition, software reserved ports can be customized to achieve control and integration of various branded instruments.
Snapshot function
Solvent alarm function
Wavelength scanning and time program wavelength
Integrated control of automatic sampler
software performance
Number of input channels: Multiple
Input voltage range: -2.5V to+2.5V;
Input impedance:>10M Ω;
Integral sensitivity: 1uV • second;
Minimum signal resolution: 1uV
Dynamic range: 107;
Minimum time resolution: 0.01min;
Linearity: ± 0.1%;
Communication method: Ethernet port.
Peak processing capability
Number of peaks that can be processed: greater than 1000 (related to computer resources);
Minimum peak width that can be processed: 0.1 seconds;
Equipped with an automatic time program;
Equipped with manual integration function;
Can automatically recognize various complex peak shapes and accurately segment them;
Baseline automatic tracking and calibration;
Automatic elimination of negative peak effects;
Compliant with GMP regulations;
Qualitative identification method for spectral peaks:
Retention time method;
Component table identification method.
Integral parameter
Peak area or peak height;
Quantitative calculation method:
Normalization method;
Internal standard method;
Grouping method;
Multi internal standard method;
External standard method.
Expert in manufacturing atomic absorption spectrophotometer/gas chromatograph
Jinan Shangdi Electronic Technology Co., Ltd. (Jinan Jingce Electronic Technology Co., Ltd.)
Contact: Han Weichao Mobile:;
Email: jnsd002@126.com
Website: www.jnsdfx.com Business
Zhengzhou Branch: Zhengzhou Qutong Electrical Equipment Co., Ltd