working principle
◇ Internal circulation: Through the operation of the outdoor compressor → discharge high-temperature and high-pressure gas from the exhaust port → enter the condenser for cooling → become low-temperature and high-pressure gas → be intercepted by the capillary tube (expansion valve) to become low-temperature and low-pressure liquid → enter the indoor host evaporator through the connecting pipe for evaporation and heat absorption → return to the compressor to become low-temperature and low-pressure gas! This cycle repeats itself.
◇ External circulation: Under normal startup conditions → through the operation of the fan → moist air is sucked in from the inlet → passes through the evaporator → the evaporator adsorbs moisture in the air onto the aluminum sheet to become dry air → blows out from the outlet.
air coolingTemperature regulating dehumidifierIt is to regulate the temperature by discharging heat to the outside through an external unit (water-cooled temperature regulating dehumidifier takes away heat through condensed water).
Occasions for use
National defense engineering, civil defense engineering, tobacco and petrochemical industries, subway stations, aerospace fields, purification engineering, laboratories
Telecommunications equipment room, archive room, food room, pharmaceutical or film workshop, special glass manufacturing, etc
The Dongjing temperature regulating dehumidifier adopts a compressor and heat exchanger, with a small overall volume, light weight, low energy consumption, and high efficiency.
◇dehumidifierFor automatic control type, there are mechanical control type and microcomputer control type. Microcomputer controlled type, automatically displays relative humidity through key input, automatically turns on or off, and performs automatic detection and control based on the humidity set by the user.
Technical Specifications
|
model |
DJFT-3881E |
||
|
Overall performance of air conditioning unit |
refrigeration capacity |
kW |
15 |
|
kcal/h |
1.29×104 |
||
|
air volume |
m3/h |
3000 |
|
|
external static pressure |
Pa |
≥300 |
|
|
Unit noise |
dB(A) |
≤75 |
|
|
Moisture control range |
%RH |
40~80%±3% |
|
|
power supply |
380V/50Hz three-phase five wire system |
||
|
Total capacity of the unit |
kW |
11.4 |
|
|
refrigeration system |
compressor |
type |
Fully enclosed vortex type |
|
quantity |
1 |
||
|
Power (kW) |
5 |
||
|
refrigerant |
type |
R22 |
|
|
Throttle method |
External balance thermal expansion valve |
||
|
evaporator |
type |
Copper tube with aluminum fins |
|
|
Heating system |
|
type |
PTC |
|
quantity |
3 |
||
|
voltage |
220V |
||
|
power |
1.5*3 |
||
|
fan system |
fan |
type |
Low noise centrifugal outer rotor |
|
quantity |
1 |
||
|
Power (kW) |
0.9 |
||
|
filter |
type |
Primary filter screen |
|
|
Overall dimensions |
Length (mm) |
1550 |
|
|
Width (mm) |
864 |
||
|
Height (mm) |
1998 |
||
|
control system |
resolution |
Humidity 1% RH |
|
|
Control method |
microcomputer control |
||
|
operating interface |
Full LCD display |
||