CAT IV 600 V CAT III 1000 V |
Option |
![]() |
||
Quickly complete professional work! Standard series with high safety and high-speed response
Standard type with DC V basic accuracy of ± 0.3% and AC V frequency characteristics of 40-1kHz
Low pass filtering to remove harmonics at 100Hz/500Hz (measurement of the fundamental component of the frequency converter)
● Equipped with multiple functions such as temperature measurement (limited to DT4253-20), C measurement, frequency measurement, etc
● High current can be measured using clamp sensors (limited to DT4251/4253 only)
● Equipped with USB communication function that meets PC measurement requirements (optional)
● Wide temperature range for use: -10 ℃ to 50 ℃
Accuracy of DMM
Due to its multiple measurement functions and ranges, DMM's basic accuracy is described as a representative value.
Please refer to the sample PDF for the accuracy of each range.
Introduction video of usage methods and functions

Introduction video of usage methods and functions
This is a video introducing the usage and main functions of the DT4200 series digital multimeter.
HIOKI's multimeter is safe and fast for measurement, supporting the daily work of electrical engineers.
A digital multimeter suitable for measuring control signals, air conditioning, and gas equipment

A digital multimeter suitable for measuring control signals, air conditioning, and gas equipment
The "Standard DT4250 Series" is designed for different purposes for each model.
DT4253 is a model suitable for measuring control signals, air conditioning, gas equipment, etc.
·DC current 60.00 μ A/600.0 μ A/6.000mA/60.00mA
·Temperature -40.0~400.0 ℃
·Can connect AC clamp sensors
Measurement of Small Current in Burner at DC600.00 μ A Range

Measurement of Small Current in Burner at DC600.00 μ A Range
Capable of accurately measuring small currents such as the frame current of a burner.
Convert the control signal 4-20mA to% and display it

Convert the control signal 4-20mA to% and display it
Convert the 4-20mA/0-20mA control signals into temperature, pressure, flow rate, etc. through sensors and other means, and display them in%.
Measure current through clamp sensors to eliminate the cause of danger

Measure current through clamp sensors to eliminate the cause of danger
When measuring voltage within the current range, a short circuit accident may occur.
By using clamp sensors for current measurement, the cause of short circuits can be fundamentally eliminated.
Removing harmonic components and accurately measuring the output voltage of the secondary of the frequency converter

Removing harmonic components and accurately measuring the output voltage of the secondary of the frequency converter
By using low-pass filtering function, harmonic components can be removed and only the fundamental wave can be measured correctly.
The measurement data is transmitted to the computer, which can confirm and save the data

The measurement data is transmitted to the computer, which can confirm and save the data
By using the communication package DT4900-01 in the optional package and connecting it to a computer, the measurement results can be displayed in real-time on the computer. Moreover, the displayed measurement values can be directly saved in text format.
The computer and tester host are isolated through fiber optic communication, ensuring safe measurement.
The software included in communication package DT4900-01 can display charts at specified intervals.
It also has the ability to accurately measure the true effective value of distorted waveforms

It also has the ability to accurately measure the true effective value of distorted waveforms
There are two measurement methods for a digital multimeter: average value and true effective value.
If the current waveform has a lot of distortion, the measurement results will also vary greatly due to different measurement methods.
In order to make accurate measurements, it is necessary to use testing instruments that use the true significant value method.
Wide angle display screen that can read data clearly from the side, with backlight that can read data even in dark areas
Wide angle display screen that can read data clearly from the side, with backlight that can read data even in dark areas
Due to the use of a wide-angle display screen, data can also be read from the side, making it convenient for on-site operation.
Equipped with high brightness backlight, data can be read even in darker areas.
Designed/manufactured in Japan, with a reliable 3-year warranty

Designed/manufactured in Japan, with a reliable 3-year warranty
The development, design, and manufacturing of HIOKI's digital multimeter were all completed at our headquarters in Nagano Prefecture, Japan. To provide high-quality products to everyone with advanced technology in the industry.
In order to achieve safe measurement, it is necessary to use testing instruments suitable for the measurement site

In order to achieve safe measurement, it is necessary to use testing instruments suitable for the measurement site
For the safe use of testing instruments, the safety level standards used as measurement levels in IEC61010 are divided into CAT II to CAT IV according to different usage locations.
Using measuring instruments that do not meet safety standards can lead to electrical accidents.