DTSY6111 Three phase Four wire Ladder Multi rate Prepaid Electric Meter
DTSY6111 Three phase Four wire Ladder Multi rate Prepaid Electric Meter
Product details


1、 Overview

The DTSY6111 three-phase four wire stepped multi rate prepaid electricity meter (hereinafter referred to as the "instrument") is designed and manufactured based on the actual electricity consumption of residents. It has high accuracy and reliability.

This instrument is designed using a dedicated chip for energy metering, combined with mature multi rate and prepaid technologies. It is an instrument product manufactured using 16 bit digital sampling processing technology and SMT process. Improved the reliability and service life of the product, and the data display adopts a large screen LCD for easy meter reading.

This instrument can realize functions such as time-sharing metering prepayment, setting daily meter reading, handheld computer programming, and meter reading; Can set 2 time zones, 3 rates, and 12 day time slots; And it has infrared and 485 communication functions, which can achieve long-distance meter reading. The communication protocol can support DL/T 645-2007 "Multi functional Energy Meter Communication Protocol", providing necessary conditions for electricity automation management.

Its performance indicators comply with the technical requirements for electronic active energy meters in GB/T 17215-2002 "Level 1 and Level 2 Static AC Active Energy Meters", meet the technical requirements for multi rate energy meters in GB/T15284-2002 "Special Requirements for Multi rate Energy Meters", and comply with various technical requirements of GB/T18460-2001 "IC Card Prepaid Electricity Sales System".

2、 Main functions

Prepaid multi rate energy meters have the following basic functions:

3.1 Real time active and reverse energy metering, which can be divided into 4 rates, 12 time periods, and 8 time zones.

3.3 Infrared communication, programming settings, and meter reading can be performed through a handheld computer.

3.4 Parameter rotation display can be implemented, and the parameters (not exceeding 32 items) and time intervals of the rotation display can be pre-set. The order of parameter rotation display can also be set arbitrarily.

3.5 Equipped with optocoupler isolation active passive pulse output interface, with the same pulse constant as the meter constant.

3.6 Record the total active power and hourly power for 12 months, and meter reading can be done through infrared or 485 methods.

3.7 It has programming prohibition function and data reset function.

3.8 Support for reduced meter reading according to departmental regulations.

3.9 It has the function of purchasing electricity first and then using it, and automatically freezing the monthly electricity consumption rates on designated meter reading days.

3.10 IC card can be used for parameter setting and meter reading.

3.11 adopts a one table one card method, with multiple verifications and encryption of data in the IC card, ensuring security and reliability.

3.12 Each time electricity is purchased, data is transmitted bidirectionally through the power card.

3.13 Can set non working hours and emergency credit limits.

3.14 Within the rated current range, the maximum operating power can be limited (by the power supply department).

3.15 has an external alarm output interface.

3.16 has built-in sound and light alarm, trip and power-off functions

a. When overloaded, it is possible to control the output of alarm and trip signals by selecting whether to allow alarm tripping.

b. When the remaining power is less than or equal to the alarm set value, the alarm and trip signals can be controlled by selecting whether the meter is allowed to output alarm and trip signals.

c. When the remaining power is zero, the meter outputs a trip signal.

3、 Working principle

When the electric energy meter is working, the voltage and current are sampled separately by the sampling circuit, and then multiplied by a dedicated integrated circuit for electric energy processing before being sent to the CPU for processing. Finally, the CPU sends the processed data to output devices such as the display and communication parts as needed.

The information system is managed by a computer, and through an IC card reader/writer, a certain amount of electricity and monitoring requirements are written into the IC card input table of the microprocessor system. After being processed by the CPU, it provides display, alarm, and cut-off status signals.

4、 Technical indicators

4.1 Accuracy level Active 1.0 Reactive 2.0

4.2 Reference voltage 220/380V

4.3 Rated current 3X 1.5 (6) A, 2.5 (10), 5 (20) A, 10 (40) A, 15 (60) A, 20 (80) A

4.4 Rated frequency 50Hz

4.5 Starting current level 1: ≤ 0.004In Level 2: ≤ 0.005In

4.6 Stealth with anti creep logic design

4.9 Electrical Parameters

Operating Voltage

0.9Un~1.1Un

Extreme working voltage

0.75Un~1.15Un

Voltage line power consumption

≤ 2W and 5VA

Power consumption of current circuit

<1VA

Data backup battery voltage

3.0VDC

4.10 Rate Working Parameters

Clock accuracy (daily error)

≤0.5S (23℃)

Battery capacity

≥1000mAh

Data retention time after power outage

≥ 10 years (using new batteries)

4.11 Climate conditions

Normal operating temperature

-20~+50℃

working temperature limit

-30~+60℃

Storage and transportation temperature

-40~+70℃

Storage and working humidity

≤85%

4.12 Technical Parameters

Number of rates

4

Number of time periods

12

Number of time zones

2

Measurement range

0~999999.99 kWh

display

Liquid Crystal (LCD)

Baud rate

RS485:1200bps~9600 bps, infrared port: 1200bps

Communication Protocol

DL/T645-2007 Multifunctional Energy Meter Communication Protocol


7、 Programming instructions

7.01 Programming allowed. The authorized person opens the programming switch button of the electric energy meter (completed by transmitting signals through an IC card), and the programming symbols are displayed on the LCD screen. The electric energy meter is in the programming state, and at this time, the handheld computer can communicate with the electric energy meter to complete the programming settings.

7.02 Data reset. If the energy meter is in the zeroing allowed state, use the zeroing card to reset all internal electricity data and historical record data of the meter. After resetting, the electricity meter displays: E=00。

7.03 Programming is prohibited. After the programming of the energy meter is completed (through signal transmission via IC card), press the programming switch button once, and the programming symbol on the LCD display screen disappears. At this time, the energy meter is in a programming disabled state, and the internal parameters of the energy meter can only be read out, not modified. Only electricity meters within the specified error range can be calibrated.

Note: In order to prevent unauthorized personnel from operating the programming switch after it is turned on, a 10 minute allowed programming time is specially set in the meter. When the time exceeds, the meter will automatically disable programming.

7.04 Table Number and Factory Number: The identification number for communication between the handheld computer and the energy meter. When reading or setting up meters, it is necessary to input the meter number or factory number of the energy meter in order for the handheld computer to communicate with the energy meter normally. The meter number can also be assigned to the user's account through the purchase of a power card. The table number of the table can be obtained by pressing the read button to view the content of item "3.1B". The factory number is assigned when the electricity meter leaves the factory and printed on the meter nameplate.

7.05 Rotation Time: The display time of each data item during rotation, with a default rotation time of 4 seconds.


7.06 Wheel Display Content Encoding: The encoding of the wheel display content that users can set according to their needs, as detailed in Appendix 3.

7.07 Automatic Meter Reading Date and Time: Programmable Meter Reading Date and Time. If the "3.1A" item (automatic meter reading date) is programmed as 28 00, the meter will automatically save the current data to the previous month's record at 0:00 on the 28th of each month. Users can set their content as needed. (If the date is greater than 28 and the time is set to 24, it will automatically switch to 01 00)

7.08 Main and Deputy Time Periods: Two time periods can be set, namely two sets of rates, such as daylight saving time.

7.09 Sub period start and end dates: If set to start date 040503 and stop date 041003.

7.10 Time slot and rate number: The peak rate number is 01; The peak rate number is 02; The flat rate number is 03; The grain rate number is 04.

7.11 Public Holidays: 24 public holidays can be set at a time.

7.12 Weekends off: You can specify a weekend for the middle of each week.

7.13 Non business hours: You can set daily non business hours. For example: 18:00-08:30.

7.14 Emergency credit limit: The limit that allows users to make emergency credit payments during public holidays, weekends, and non business hours can be set.

The above management parameters can be transmitted from the management system to the user's electricity meter through preset cards and purchase cards.

7.15 Date: should be the current accurate date.

7.16 Time: should be the current accurate time.

The date and time should be regularly checked on-site.

8、 Installation and wiring

8.1 The instrument shall be inspected and sealed with lead before leaving the factory. Before installation and use, it is necessary to check whether the lead seal is intact. If the lead seal is intact, it can be installed and used. For instruments without lead seals or stored for too long, relevant departments should be asked to re inspect them. Only qualified instruments can be installed and used.

8.2 The instrument should be installed in a ventilated and dry indoor area, fixed with three screws, and drilled with holes on the bottom plate according to the installation size shown in Figure 1 (150 × 231). The base should be fixed on a sturdy, fire-resistant, and non vibrating object to ensure safe and reliable installation and use. In places with pollution or potential damage to the instrument, the instrument should be protected by a protective cabinet.

8.3 The instrument should be wired correctly according to the wiring diagram. It is recommended to use copper wire or copper connectors for the incoming wires of the terminal box. The screws inside the terminal box should be tightened to avoid burning due to poor contact or thin leads.

8.4 The instrument will enter normal operation after being powered on with the correct wiring as described above.

9、 Transportation and storage

The product should not be subjected to severe impact during transportation and unpacking.

Inventory and storage should be stored on racks in their original packaging conditions, with a stacking height not exceeding 5 layers.

The storage location should be clean, with an ambient temperature of 0-40 ℃, a relative humidity not exceeding 85%, and no harmful substances in the air that can cause corrosion.

10、 Guarantee period

From the date of sale, if the user complies with the requirements specified in the manual and the manufacturer's lead seal is still intact, the company provides a 2-year warranty for the electric energy meter


Appendix

3.3Main time period and rate setting

1. Set corresponding electricity prices for peak, off peak, off peak, and off peak rates according to the prescribed electricity pricing policy.

Period 2: Peak period from 08:00 to 11:30

Period 3: 11:30 to 18:30 Flat

Time slot 4: Peak period from 18:30 to 23:00

Time slot 5: Valley section from 23:00 to 07:00

The minimum interval between time periods is 5 minutes, and time periods can cross zero.

Unable to provide emergency credit, therefore the daily time slot number does not work.

3.7Setting of sub time periods

Divide the internal rates of the meter into two sets, one as the main rate (operating rate) and the other as the secondary rate (standby rate). The primary and secondary rates can be switched between each other (following the setting command). If the superior notifies that the rates and time periods need to be adjusted, the staff can set them several days in advance and ensure that all the meters set are converted on the same day and at the same time. This not only provides sufficient working time (lead time), but also ensures that policies are implemented at the same time (reducing the difficulty of electricity calculation software)

A、 The sub time period setting is similar to the main time period setting, please refer to the main time period section.

B、 Time period start and end date setting: The identification code (8119) can be set in four situations:

i. Starting from 04.10.01, execute the sub period: 8119=000000 041001

Ii. From the current date until 04.10.01: 8119=041001 000000

Iii. Execution from 04.06.01 to 04.10.01: 8119=041001 040601

Iv. Stop sub period: 8119=000000 000000

The start and end dates of the sub period are set in the 811F load control package and transmitted to the user's electricity meter.

4、 Accident handling:

(1) When an unexpected malfunction occurs in an already opened electricity meter, or when the meter is damaged by human operation (the meter cannot operate), open the meter and save the E data stored in the already opened meter2If the PROM display board is unplugged and replaced with a new meter, the new meter can replace the original meter and all data will be the same as the fault meter. (The nameplate of the electric meter also needs to be replaced with a new one)

(2) When the allowed load and remaining power exceed the pre-set values, and the available power of the meter is zero, the meter will output an alarm or trip signal.

Attention: When both alarm and trip are selected, trip takes priority over alarm.

(3) When the remaining power of the meter is 0 and the external power supply circuit cannot be disconnected due to emergency credit or other reasons, the meter will start calculating the overdrawn power and automatically deduct the overdrawn power when the next power card is inserted.


Appendix 2 Explanation of User Precautions

1. One table, one card:

The IC card held by the user cannot be exchanged. In case of loss, a replacement card should be purchased from the power supply department (sales office).

2. Preparation for purchasing electricity:

Before purchasing electricity, users must insert their IC card into the electricity meter once to facilitate the return of data from the meter to the computer database.

3. When purchasing electricity, please declare the amount of electricity to be purchased and the alarm reminder amount.

4. Electricity card usage: Insert the purchase card into the electricity meter. If it is a valid purchase card, the electricity meter will automatically read the data into the meter. The LCD display screen will show the following electricity purchase information in sequence: 8100 total purchased electricity, 8101 remaining electricity, 8102 overdrawn electricity, 8103 purchased electricity, 8104 meter times, 8105 alarm electricity, 8106 storage limit, 8107 credit limit, 8108 limited capacity power, 8109 purchased electricity date, etc. Please store the unplugged card properly.

5. Operation display: During the operation of the electricity meter, it alternately displays the total average electricity, peak and valley electricity, remaining electricity, and operation period in the meter.

6. Overcapacity alarm: During the operation of the electricity meter, if the "alarm" LED indicator flashes rapidly, it warns the user that the electricity has been exceeded. If the meter is set to the over capacity power-off limit mode, after 30 seconds of over capacity power consumption, it will be tripped for 3 minutes and the countdown display (180 seconds) will show the time to restore power supply; The user's card insertion response can immediately restore power supply.

7. Accumulation limit: If the purchased electricity+remaining electricity>accumulation limit (e.g. 9999kWh), the purchased electricity will not be read in, and the display will show a prompt of "8106 NNNNNN", indicating that the electricity in the card is still valid.

8. Warning reminder: When the remaining battery level in the meter is less than twice the "alarm battery level", the "alarm" LED indicator will flash (with an interval of 1 second) to remind the user to purchase electricity. At this time, if the user responds by inserting a card, the "alarm indicator" will flash at an interval of 2 seconds to avoid power outage warnings.

9. Power outage warning: If the user does not respond by inserting the card during the warning reminder, when the remaining power is the alarm power agreed upon by the user (or 10% of the purchased power), the electricity meter will be tripped and a power outage warning will be issued. At this time, inserting the IC card into the electricity meter once will restore power supply. If the IC card of this meter cannot be found after pulling the switch, you can borrow a neighbor's IC card to insert it and restore power supply.

10. Power purchase reminder: When the remaining power in the meter is less than the "alarm power", the "alarm" LED indicator will remain on as a constant reminder.

11. Fault declaration: When the remaining power is displayed as zero or negative, the "alarm" LED indicates. If the meter continues to operate (except for emergency credit), the user should immediately purchase electricity and proactively report the situation to the power supply department.

12. Emergency credit can be granted during non working hours, weekends, and public holidays. When the battery level is zero and the business outlet cannot purchase electricity without going to work, a power purchase card can be inserted to activate emergency credit. Emergency credit for electricity cannot exceed the 'credit limit'.

13. When emergency credit is due, the electricity load is limited, and users should purchase electricity as soon as possible to avoid affecting their daily lives.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!