major function
Measurement of basic electrical parameters such as three-phase current, three-phase voltage, three-phase power, and frequency, as well as reactive energy measurement
◆ Phase sequence error indication of three-phase voltage and current, power symbol error indication
◆ Active pulse output indication, communication transmission and reception indication, reverse phase indication
◆ Support button setting function
◆ Current piercing direction setting
After power failure, all stored data will not be lost and can be maintained for more than 10 years
LORA channels can be set up through buttons or communication settings.
◆ Connect with the collection system through the supporting LOAR gateway device
■ LORA interface
Adopting a voltage CT isolation scheme to ensure that the antenna interface is isolated from the mains power at a voltage of over 2KV; The baud rate cannot be set, fixed at 9600 n 8 1
■ Communication protocol
◆ Supports Modbus RTU protocol and some DLT645-2007 protocols
■ Appearance
◆ Adopting a guide rail installation shell
■ Display format
◆ 8-bit LCD segment code display, supporting cyclic display and button display; 3 LED status indicators
■ Installation method
◆ 35mm standard DIN rail shell, flexibly adaptable to various distribution cabinets.
performance parameter
|
performance |
parameter |
||
|
Input measurement |
electricity press |
measuring range |
220V ±20% |
|
accuracy |
RMS accuracy: Level 0.5 |
||
|
electricity flow |
range |
1A~1000A (mA level input) |
|
|
accuracy |
RMS measurement (current accuracy: 0.5 level) |
||
|
frequency |
Three phase AC 50Hz voltage and current; |
||
|
power |
Active accuracy: Level 0.5; Reactive power accuracy: Level 1 |
||
|
Power factor |
Power factor accuracy: Level 0.5; |
||
|
electric energy |
Active power level 1, reactive power level 2 |
||
|
transport go out approve weave Cheng |
open up or clear out by poking or jabbing interrogate |
output interface |
LORA interface, TTL (used for factory configuration) |
|
Communication Protocol |
Standard MODBUS-RTU communication protocol DL/T645-2007 Protocol (Partial) |
||
|
data format |
TTL (fixed at 9600, N,8,1) |
||
|
COMMUNICATION RATE |
|||
|
pilot lamp |
3 (representing communication lights, pulse lights, and reverse lights respectively) |
||
|
display |
8-bit LCD segment code display |
||
|
Active energy pulse output |
Pulse width 80ms ± 20ms, optically isolated |
||
|
ring area |
work environment |
Working temperature: -20~60 ℃ |
|
|
storage environment |
Storage temperature: -40~80 ℃ |
||
|
relative humidity |
Relative humidity ≤ 95%, no condensation |
||
|
peaceful complete |
pressure resistance |
Voltage signal and pulse withstand voltage>4KV, leakage current<2mA |
|
|
isolation |
Output, input, and power supply to casing>5M |
||
|
Resistance Disturbance linear measure |
Fast transient pulse |
>4kV |
|
|
Lightning Protection |
>4kV |
||
|
air discharge |
>8kV (national standard is 15KV) |
||
External dimensions