Shanghai Hujing Medical Equipment Co., Ltd
Home>Products>DOP efficient air supply outlet
DOP efficient air supply outlet
Brief description: DOP high-efficiency air supply outlet: It is an ideal terminal filtration device for thousands, tens of thousands, and hundreds of
Product details
brand Other brands Origin category domestic
application area Environmental protection, chemical industry, petroleum, electronics, pharmaceuticals

The high-efficiency air supply outlet is an ideal terminal filtration device for thousands, tens of thousands, and hundreds of thousands level purification air conditioning systems, which can be widely used in purification industries such as medicine, health, electronics, and chemical engineeringair-conditioning systemThe high-efficiency air supply outlet is used for renovation and new constructionThe terminal filtration device for cleanrooms at levels 1000-300000 is a key equipment that meets purification requirements. Efficient air supply outlet includesplenum chamber, diffuser plate,High efficiency filterThe interface with the air duct can be top or side connected.

Efficient air supply outletThere are two series, I and II. Series I is replaceablefilterForm, SeriesII is a disposable air outlet form, all of which are downward air supply.

Efficient air supply outlet seriesI: This air outlet is composed ofHigh efficiency filterHigh qualitySteel sheetAluminum alloy diffusionperforated plateEqual composition, easy installation, reliable sealing, and convenient replacement of filters. The takeover method can be either top or side connected.

Efficient air supply outlet seriesII: There are two types: ultra-thin and thin. All are disposable air vents, easy to replace (only need to remove the air supply duct and the air vent)flexible jointofcouplingJust enough). This series is particularly suitable for purification air conditioning systems with limited ceiling space. Main advantages: The box structure is simple and reliable, with strong ventilation, uniform air supply, easy installation, and simple maintenance.

DOP efficient air supply outletstructure

1. The box is made of high-quality cold-rolled steel plate, with an outer surfaceElectrostatic sprayingProcessing, equipped with a diffuser plate.

2. Bottom mounted high-efficiency filter, easy to replace;

3. The structure is compact and the sealing performance is reliable. There are two types of air inlet methods: side inlet and top inlet. The flange mouth has two structures: square and circular.

4. Sometimes, when the cleanroom is limited by the height of the civil engineering or requires a compact design, an integrated design can be chosenEfficient filter air outlet.

5. Filtration efficiency:≥ 99.99% (dust particles ≥ 0.3 μ m); P-type: filtration efficiency: ≥ 99.995% (≥ 0.3 μ m dust particles)

6. Initial resistance:≤230Pa

7. YesXPSStainless steel materialAvailable for selection.

DOP efficient air supply outletInstallation precautions

1. Before installation, it is important to note that the size and efficiency requirements of the high-efficiency air supply outlet must comply with the on-site design requirements of the clean room and customer application standards

2. Before installing the high-efficiency air supply outlet, it is necessary to clean the product and clean the cleanroomCleaning and cleaning, such as purifying dust in the air conditioning system, should be carried out to meet the cleaning requirements and standards. The interlayer or ceiling also needs to be cleaned. The air conditioning system must be tested and operated continuously for more than 12 hours before being cleaned again.

3. The safe transportation of efficient air supply outlets must strictly follow the manufacturer's instructions and directions. During transportation, they should be handled gently and avoid severe vibrations and collisions.

Before installing the high-efficiency air supply outlet, it is necessary to conduct on-site inspectionsAir supply outletConduct a visual inspection of the packaging, including whether the filter paper, sealant, and frame are damaged; Whether the side length, diagonal, and thickness dimensions meet the requirements; Whether the frame has burrs and rust spots (metal frame); Yes NoProduct Qualification CertificateWhether the technical performance meets the design requirements.

5. Conduct efficient leak detection of air supply outlets, check and verify if the leak detection is qualified. During installation, reasonable adjustments should be made based on the resistance of each air supply outlet. For one-way flow, the difference between the rated resistance and average resistance of each filter on the same air outlet or air supply surface should be less than 5%. Efficient air supply outlets for cleanrooms with cleanliness levels equal to or higher than Class 100.

6. The clean room needs to install efficient air supply vents and seal the joints between the vent flanges and the ceiling panels with gaskets. Remember to strictly handle any cracks. Do not install if the high-efficiency air supply outlet is damaged or the coating is damaged,Air supply outletThe installation and air duct must be strictly connected, and the open end should be reinforced with plastic film and tape for air tightness treatment. The above seven precautions must be carefully followed. Any slight deviation directly affects the cleanliness standards of the entire cleanroom,

Technical parameters:

model

Rated air volume

Efficient filter size

External dimensions

Size of air duct flange

Ceiling opening size

weight

Top inlet air

Side inlet air

m3/h)

mm)

KxLxH/h(mm)

AXB(mm)

mm)

Kg)

□-051I

□-051II

500

400X400X80(H13)

450X450X360

/480

200X200

460X460

20

□-051IP

□-051IIP

400X400X80(H14)

20

□-051IPL

□-051IIPL

400X400X105 (liquid tank)

22

□-101I

□-101II

1000

610X610X69(H13)

660X660X360

/480

320X250

670X670

36

□-101IP

□-101IIP

610X610X69(H14)

36

□-101IPL

□-101IIPL

610X610X105 (liquid tank)

39

□-151I

□-151II

1500

630X630X80(H13)

680X680X360

/480

400X250

690X690

43

□-151IP

□-151IIP

630X630X80(H14)

43

□-151IPL

□-151IIPL

630X630X105 (liquid tank)

47

□-201I

□-201II

2000

915X610X80(H13)

965X660X360

/480

630X250

975X670

53

□-201IP

□-201IIP

915X610X80(H14)

53

□-201IPL

□-201IIPL

915X610X105 (liquid tank)

58

□-251I

□-251II

2500

1220X610X80(H13)

1270X660X360

/480

630X250

1280X670

60

□-251IP

□-251IIP

1220X610X80(H14)

60

□-251IPL

□-251IIPL

1220X610X105 (liquid tank)

65

□-301I

□-301II

3000

1260X630X80(H13)

1310X680X360

/480

630X250

1320X690

65

□-301IP

□-301IIP

1260X630X80(H14)

65

□-301IPL

□-301IIPL

1260X630X105 (liquid tank)

70