Jiangsu Jiachen Environmental Technology Co., Ltd
Home>Products>Continuous online monitoring system for mercury in flue gas
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    No. 805 Jingxian Road, Lingang Street, Jiangyin City, Jiangsu Province
Contact Now
Continuous online monitoring system for mercury in flue gas
The system collects sample gas through a probe, and after heating and dry chemical treatment, the sample gas is converted into gas, which is then cont
Product details

The system collects sample gas through a probe, and after heating and dry chemical treatment, the sample gas is converted into gas, which is then continuously measured by a photodetector. The mercury concentration is calculated and displayed. When measuring total mercury in garbage, heating and dry chemical treatment are used to remove Hg from the sample gas2+Reduce to Hg for measurement; When measuring elemental mercury, the sample gas is not subjected to any treatment; The difference between total mercury and elemental mercury is the ionic mercury content.

• Automatic calibration
Total mercury, elemental mercury, and ionic mercury can all be measured
• Low cost of ownership
• Simple operation and safe design
• Simple and compact structure, easy to maintain
High detection sensitivity, accurate detection results, fast detection speed, and easy operation
High reliability, very suitable for on-site use
No additional reagents are required, avoiding reagent contamination during the measurement process


Measurement objectOptional ionic mercury, elemental mercury, and total mercury content
Measurement range0-45.0-75.…0-500g/Nm³
Measurement principleDOAS technology
Smoke temperature0-250℃
Smoke pressure-5Kpa to+5Kpa
Pipe diameterGreater than 0.5m
Environmental temperature+5 to+30 ℃
Protection level1P40(IP54)
Measurement output2×4-20mA500ohm
Digital output4-channel relay output allows for a load of 250V/100VA
Digital input1 passive input
Uncertainty5.5%CR( Certifed Range )
Testing*Less than 0.1ug/Nn ³
Reference point driftLess than 2% CRE ³
Zero driftAutomatic zero point correction, less than 0.5% CRE
Supply voltage230 /400VAC 50HZ,3XL, N,PE
Dimensions (H × W × D)Cabinet: 1700 × 800 × 500mm
Weight220kg
Blow the wind6~8ba compressed air (only for standard gas generators)
Cabinet: 1200VA
Power consumptionSampling head 650V
Sampling pipeline: 100VA per meter
Sampling pipeline: 100VA per meter
Heating sampling tube: 600VA, 800VA, 1200VA
CREEnd of Certified Range


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!