Water bath constant temperature oscillator model:JKH71-SHA-C
Water bath constant temperature oscillatorProduct Description:Water bath/The gas bath isThe main product produced by our factory.
The water bath produced by our factory is also known as the water bath constant temperature shaker,Divided by function, there are reciprocating and revolving types.Dual functional type.Room temperature type.low-temperature type.High temperature type, etc.water bathEquipped with stainless steel universal fixtures, digital temperature control, stepless speed regulation, and excellent thermal cycling function.It is a versatile biochemical instrument that is indispensable laboratory equipment for precision cultivation and preparation in fields such as plants, biology, microbiology, genetics, viruses, environmental protection, and medicine.
water bathScope of use:It is mainly suitable for oscillation cultivation of various liquid and solid compounds such as biology, biochemistry, cells, and bacterial strains in research departments such as universities, oil and chemical engineering, health and epidemic prevention, and environmental monitoring.water bathIt has the characteristics of reasonable structure, easy operation, and high stability, making it an ideal equipment for laboratory workers to handle with ease.
water bathDetailed parameters:
Indicator/model |
SHA-Creciprocating |
THZ-82swirl |
SHA-Bdual-function |
speed range |
start-300r/min |
start-300r/min |
start-300r/min |
Temperature control range |
room temperature-100℃ |
room temperature-100℃ |
room temperature-100℃ |
Temperature control accuracy |
±1℃ |
±1℃ |
±1℃ |
vibrateCCwidth |
25mm |
20mm |
25,20mm |
heating power |
1200W |
1200W |
1200W |
pretendbottlequantity |
Test tube: ¢16×200 |
Test tube: ¢16×200 |
Test tube: ¢16×200 |
timing range |
0-120min(or normally open) |
0-120min(or normally open) |
0-120min(or normally open) |
electricitysource |
communication220V50Hz |
communication220V50Hz |
communication220V50Hz |
Overall dimensions |
700×600×400 |
700×600×400 |
700×600×400 |
Instructions for using water bath
1,Please read this manual carefully before use.
2、The working surface of the machine should not be excessively smooth (such as tiles, etc.).
3、The electrical rated parameters of the socket provided by the user should not be less than the electrical rated parameters of the machine, and there should be good grounding measures.
4、The whole machine is strictly prohibited from being used in an environment with direct sunlight.
5、The speed control should start slowly from low speed to high speed.
6、The machine may experience some displacement during high-speed oscillation, so it should be monitored by someone during use.
water bathInstructions for Use
1、Load the test bottle and maintain balance. If it is a dual function model, set the oscillation mode. (For detailed settings, please refer to the following diagram)
2、Turn on the power and set the timer according to the surface scale of the machine. If you need to work for a long time, adjust the timer to“Normally Open'Location.
3、Turn on the power switch and set the constant temperature:
(1)Place the control switch in“setting'At this point, the temperature displayed on the screen is the set temperature. Adjust the knob to set it to the temperature you need for your work. (The working temperature you set should be higher than the ambient temperature. At this time, the machine starts heating up and the yellow indicator light is on. Otherwise, the machine will not work.)
(2)Place the small switch in the control section“measurement'At this time, the temperature displayed on the screen is the actual temperature of the air inside the test chamber. As the temperature inside the chamber changes, the displayed number will also change accordingly.
(3)When heated to the desired temperature, the heating will automatically stop and the green indicator light will turn on; When the heat inside the test chamber dissipates below the temperature you set, a new round of heating will begin.
4Activate the oscillation device:
(1)Turn on the oscillation switch on the control panel, and the indicator light will turn on.
(2)Adjust the oscillation speed knob to the desired oscillation frequency.
5After completing the work, cut off the power and set the speed control knob and temperature control knob to the lowest point.
6Clean the machine and keep it clean.
Using a water bath(Shaker bed)Precautions
1、Instruments should be placed on a sturdy workbench, with a clean and tidy environment and good ventilation.
2、The power socket provided by the user should have good grounding measures.
3、It is strictly prohibited to move the machine during normal operation.
4、It is strictly prohibited for objects to collide with the machine.
5TheChildren are strictly prohibited from approaching the machine to prevent accidents.
6、Before replacing the fuse, ensure that the power supply has been cut off.
7、After use, please clean the machine without leaving any water droplets or dirt residue.
The water bath produced by our factoryand: Water bath;Water bath constant temperature shaker;Dual function water bath oscillatorWater bath oscillatorWater bath shakerRotary water bath oscillatorLow temperature water bath oscillatorReciprocating water bath oscillator Dual function water bath constant temperature shaker Rotating water bath constant temperature shaker Reciprocating water bath constant temperature shaker