Constant pressure testing equipment
Product use: The high, low temperature, and low pressure test chamber is mainly used in aviation, aerospace, information, electronics, and other field
Product details
Equipment model Studio size (D * W * H) mm Dimensions (D * W * H) mm
LRHS-101B-LF 450×450×500 1500×1120×1930
LRHS-225B-LF 500×600×750 1550×1270×2160
LRHS-504B-LF 700×800×900 2000×1470×2290
LRHS-800B-LF 800×1000×1000 1900×1560×2550
LRHS-1000B-LF 1000×1000×1000 2100×1560×2550
sexually
ability
finger
treetop
temperature range A:-20℃~150℃ B:-40℃~150℃
C:-60℃~150℃ D:-70℃~150℃
temperature uniformity ≤ 2 ℃ (when unloaded)
temperature fluctuation ± 0.5 ℃ (when unloaded)
Pressure Range Normal pressure (100KPa)~1KPa
Pressure deviation Normal pressure~50Kpa: ± 2Kpa;
heating rate RT~150 ℃ ≤ 60min (at atmospheric pressure without load)
cooling rate RT~-40 ℃ ≤ 40min (at atmospheric pressure without load)
Voltage reduction time ≤ 45 minutes (atmospheric pressure~30KPa)
Time setting range 1~60000M
Air cooling method Multi stage membrane air heat exchanger
Pressure regulation method Dynamic pressure balance method
send
use
material
material
External material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304, pressure bearing layer reinforced with thickened stainless steel
Insulation material Rigid polyurethane foam+glass fiber
pit
the heart
join in marriage
place
temperature controller Imported "Youyi Control" brand temperature instrument
temperature sensor PT100 platinum resistance thermometer
Cooling method Single machine or double machine cascade refrigeration
compressor Taikang, France/Bizelle, Germany
Safety protection Compressor overpressure overload, fan motor overheating, overall equipment under phase/reverse phase
Overtemperature, overall equipment timing, leakage protection, overload and short circuit protection
supply voltage AC380V±10% 50Hz
Power (A)12kW/16kW/20kW/24kW/28kW
(B)17kW/22kW/27kW/31kW/35kW
(C)20kW/25kW/34kW/38kW/42kW
Usage environment 5℃~+28℃ ≤85% RH
Note:
1. The above data were measured under good ventilation conditions at an ambient temperature of 25 ℃
2. Custom constant pressure testing equipment can be customized according to specific testing requirements of users
3. This technical information is subject to change without prior notice

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!