VIP member
Como170 Surface Pollution Measuring Instrument
The BN-320A surface contamination measuring instrument uses thin film double flashing and effective light measurement to achieve efficient measurement
Product details
Product Introduction:
The BN-320A surface contamination measuring instrument uses thin film double flashing and effective light measurement to achieve the measurement of alpha, beta, and gamma rays
Efficient measurement; Single button completion of instrument power on/off and recording of measurement data of concern; The color touch screen allows for intuitive and quick setting of instrument parameters. Different calibration efficiencies can be set for different nuclides. Widely applicable to environmental protection, disease control, nuclear industry, etc.
Technical indicators:
ZnS (Ag) plastic scintillator detector
Effective detector size of 100 × 150 × 1mm
The transparency is 87.5%, with a sturdy honeycomb grid of 0.5mm, and the total transparency is 83% when combined with the external structure
64K true color LCD touch screen with a resolution of 480 × 320
The measured values can be displayed using CPS or differentiated between nuclide Bq and Bq/cm2 display
Radionuclide sensitivity: 241Am>40%; 90Sr-90Y>42%
Uniformity of detection within the effective area of the detector: ≥ 80%
Working temperature: -10 ° C to+40 ° C
Protection level IP53
Dimensions: Length 305 x Width 127 x Height 116
Weight: ≤ 450g
Product Features:
One probe can measure both alpha and beta/gamma surface contamination simultaneously
Single button start/stop measurement and recording measurement data, instrument function menu is intuitively displayed on the touch screen
The power circuit of the detection device adopts overvoltage protection and battery reverse installation protection
Alarm threshold touch screen setting, sound, light and vibration alarm in case of exceeding the threshold or malfunction
The detection device adopts a sealed conductive shell to ensure the integrity of the internal electromagnetic shielding
Intelligent probe with self checking function and Bluetooth data transmission
Electromagnetic compatibility meets G requirementsAppendix D of B/T 11684-2003
The BN-320A surface contamination measuring instrument uses thin film double flashing and effective light measurement to achieve the measurement of alpha, beta, and gamma rays
Efficient measurement; Single button completion of instrument power on/off and recording of measurement data of concern; The color touch screen allows for intuitive and quick setting of instrument parameters. Different calibration efficiencies can be set for different nuclides. Widely applicable to environmental protection, disease control, nuclear industry, etc.
Technical indicators:
ZnS (Ag) plastic scintillator detector
Effective detector size of 100 × 150 × 1mm
The transparency is 87.5%, with a sturdy honeycomb grid of 0.5mm, and the total transparency is 83% when combined with the external structure
64K true color LCD touch screen with a resolution of 480 × 320
The measured values can be displayed using CPS or differentiated between nuclide Bq and Bq/cm2 display
Radionuclide sensitivity: 241Am>40%; 90Sr-90Y>42%
Uniformity of detection within the effective area of the detector: ≥ 80%
Working temperature: -10 ° C to+40 ° C
Protection level IP53
Dimensions: Length 305 x Width 127 x Height 116
Weight: ≤ 450g
Product Features:
One probe can measure both alpha and beta/gamma surface contamination simultaneously
Single button start/stop measurement and recording measurement data, instrument function menu is intuitively displayed on the touch screen
The power circuit of the detection device adopts overvoltage protection and battery reverse installation protection
Alarm threshold touch screen setting, sound, light and vibration alarm in case of exceeding the threshold or malfunction
The detection device adopts a sealed conductive shell to ensure the integrity of the internal electromagnetic shielding
Intelligent probe with self checking function and Bluetooth data transmission
Electromagnetic compatibility meets G requirementsAppendix D of B/T 11684-2003