Product details configuration
Eliminate the vibration impact of fan components on the unit
Customer Case
Integrated refrigeration of low-temperature chiller units by China Salt Group
Yanzhong Beverage Process Cooling Integrated System
Cube Pharmaceutical Integrated Industrial Refrigeration
Advantages of Stellar Seasons
20 Technology Sedimentation Casting Fine Star Seasons
20 years of production and manufacturing experience, 3 major production bases, 50000 square meters of production plants, fully automated production lines, national calibration and testing system, 108 production processes with strict quality control management to ensure that the quality of each product meets national quality standards
40 patented technologies save 30% energy
Jointly established a refrigeration system project design and research institute with the University of Science and Technology of China, with 4000 industry solution experiences, over 40 patented technologies, and energy savings of over 30% in operation
Professional technical team provides free solution design
A technical team of 20 people provides free targeted overall solutions for different enterprise project situations. According to enterprise needs, customized and reliable systems can be provided to safeguard enterprise production
Double after-sales service guarantee solves worries
7 × 24-hour after-sales service team, IoT mobile APP remote monitoring system, providing fault warning function to reduce the impact of equipment failure, lifetime warranty, and helping enterprise development
| Unit model | air volume | Residual pressure | Four rows of cooling capacity | Six row cooling capacity | Heating capacity of hot water | Steam heating capacity | Regenerated electric heating capacity | Electrode humidification capacity | Motor power |
| TZK | CMH | Pa | kw | kw | Kw (2 rows) | Kw (single row) | kw | kg/h | kw |
| HM030 | 3000 | 500 | 10.4 | 13.4 | 20 | 39 | 9 | 4 | 1.5 |
| HM040 | 4000 | 500 | 14.8 | 16.9 | 26 | 52 | 12 | 5 | 2.2 |
| HM050 | 5000 | 500 | 18 | 23.6 | 33 | 65 | 15 | 10 | 2.2 |
| HM060 | 6000 | 500 | 20.7 | 27 | 40 | 78 | 18 | 10 | 3 |
| HM080 | 8000 | 500 | 28.2 | 33.7 | 52 | 104 | 24 | 13 | 4 |
| HM100 | 10000 | 600 | 39.1 | 45.6 | 65 | 130 | 30 | 13 | 5.5 |
| HM120 | 12000 | 600 | 44.6 | 54.8 | 80 | 156 | 36 | 15 | 5.5 |
| HM150 | 15000 | 600 | 58.2 | 63.4 | 98 | 195 | 45 | 15 | 7.5 |
| HM180 | 18000 | 600 | 66.4 | 76.6 | 120 | 234 | 54 | 25 | 11 |
| HM200 | 20000 | 700 | 79.1 | 95.7 | 130 | 260 | 60 | 30 | 11 |
| HM230 | 23000 | 700 | 88.4 | 113.9 | 150 | 300 | 60 | 30 | 11 |
| HM250 | 25000 | 700 | 96.3 | 116.9 | 163 | 325 | 72 | 45 | 15 |
| HM280 | 28000 | 700 | 104.9 | 127.6 | 182 | 364 | 72 | 45 | 15 |
| HM300 | 30000 | 700 | 108.9 | 137 | 195 | 390 | 75 | 45 | 15 |
| HM350 | 35000 | 800 | 131.9 | 164 | 225 | 450 | 90 | 60 | 18.5 |
| HM400 | 40000 | 800 | 153.3 | 174 | 260 | 520 | 100 | 60 | 22 |
| HM450 | 45000 | 800 | 160.4 | 205.7 | 290 | 580 | 108 | 60 | 30 |
| HM500 | 50000 | 800 | 178.4 | 234 | 325 | 650 | 120 | 75 | 30 |
| HM550 | 55000 | 800 | 196.2 | 257.4 | 355 | 715 | 134 | 75 | 30 |
| HM600 | 60000 | 800 | 214.1 | 280.8 | 390 | 780 | 144 | 90 | 37 |
-
Note:
1. Refrigeration nominal operating conditions: inlet air dried bulb at 28 ℃, inlet wet bulb at 18 ℃, inlet water temperature at 12 ℃, and supply and return water temperature difference at 5 ℃.
2. Heating nominal operating conditions: inlet air drying bulb at 15 ℃, inlet water temperature at 60 ℃, outlet water temperature at 50 ℃.