This analyzer is a fully automatic environmental online instrument developed according to the national standard analysis method. The instrument automatically completes the entire process from water sample collection, analysis and reaction to measurement value display, storage, and remote data transmission. Widely used in the detection of industrial and domestic wastewater, automatic detection of various contents in lake and river sections, and control of total pollutant discharge.
Adopting sequential injection fixation ring technology, the structure is simple, the failure rate is low, the use of reagents is minimal, and the operating cost is low.
The quantitative system is stable and reliable, superior to conventional photoelectric quantification and quantitative tube quantification, and will not decay during long-term operation.
The automatic alarm for instrument failure and automatic recovery after power outage overcome the disadvantages of short service life and high failure rate of similar products.
Humanized design, easy operation, all functions of the instrument are completed through a friendly human-machine interface on the touch screen.
The instrument calibration, parameter recording, and analysis time can be set through remote control.
The device has a simple structure and is easy to maintain. Operators can operate it proficiently after simple training.
Strong universality, a universal platform for all chemical instruments, facilitating the stocking of spare parts in the later stage and shortening maintenance cycles.
Easy to customize, with proportional coefficients between ranges - fixed, enabling accurate measurement of all ranges with a single calibration range.
High stability and significantly better repeatability than the national standard.
Measurement principle: Rapid digestion spectrophotometry
Measurement range: (0-200.0mg/L) ; (0-1000.0mg/L) ; (0-5000.0mg/L) ; Scalable definition
Accuracy: standard solution and water sample concentration, ≤ 50mg/L, not exceeding ± 5mg/L; Standard solution and water sample concentration ≥ 50mg/L, not exceeding ± 10%, repeatability not exceeding 5%
Masking ability: can mask 30000mg/L Cl
Cycle: 45 minutes
Sampling period: time interval (0-9999min can be set arbitrarily) and 24-hour hourly measurement mode
Calibration cycle: calibration time can be set
Output signal: RS-232 and (4-20) mA output (output ports can be added according to actual situations)
Environmental temperature: recommended temperature (5-40) · c; Humidity ≤ 85% (non condensing)
Power supply: (220 ± 22) VAC; (50 ± 0.5) Hz
Size: 600 * 450 * 1560mm
Other: Instrument abnormal alarm, power outage data automatically saved;
60000 color TFT touch screen display and command output; Automatic restoration of working status after abnormal reset and power outage when power is restored