Jiangsu Zhonghuo Sensing Technology Co., Ltd
Home>Products>CHVS5/25A Hall sensor module closed-loop voltage (current) sensor
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    No. 99 Xingfa Road, Jiangning District, Nanjing City
Contact Now
CHVS5/25A Hall sensor module closed-loop voltage (current) sensor
CHVS5/25A Hall sensor module closed-loop voltage (current) sensor
Product details

CHVS025AThe series sensor is a Hall voltage (current) sensor based on the closed-loop magnetic balance principle.Capable of directly measuring DC, AC, pulse, and various irregular currents. The preferred solution for voltage measurement has excellent cost-effectiveness and can also be used formAMeasurement of small current levels.

give birth to product special nature

answer use

  • high-precision
  • Good linearity
  • Low temperature float
  • Low response time
  • High anti-interference ability
  • Variable speed drive
  • Battery application
  • UPSUPs
  • Application of Inverter Power Supply
  • Solar combiner box
  • Accurate measurement of small current

Electrical characteristics:

CHVS5/25A

CHVS10/25A

Rated currentIPN(mA)

5

10

Measurement rangeIP(mA)

7

14

Measure voltageVPN(V)

5-1500

10-1500

Sampling resistorRM(?)

With±15V

@±5mAmax

100?(min)

350?(max)

@±7mAmax

100?(min)

190?(max)

@±10mAmax

100?(min)

350?(max)

14mAmax

100?(min)

190?(max)

Wire turn ratio

5000:1000

2500:1000

Rated output currentISN(mA)

25±0.5%

Power supplyVc(±5%)

±15V

Isolation Voltage

50Hz, 1min,3.5kV

Creepage distance mm

19.5

Current lossIc (mA)

15+IS

Dynamic parameters:

Rated accuracyXG @IPN,T=25°C

±0.5

%

Zero offset currentIo@IP=0,T=25°C

≤±0.1

mA

Zero temperature driftIo@ -40°C--85°C

≤±0.5

mA

Linearityεr

<0.2

%FS

Response timetr

<40

µs

General characteristics:

operation temperature

-40 ~+85

°C

Storage temperature

-40~+125

°C

Working humidity

20-90No condensation

%

Internal resistance of primary coil

CHVS5/25A

650

?

CHVS10/25A

200

?

Internal resistance of secondary coil

CHVS5/25A

110

?

CHVS10/25A

110

?

weight

27

22

g

other:

authentication

CE

Quality system

ISO9000

ISO14001

Execution standards

JB/T7490-2007/EN50178

Structural diagram (mm)CHVS025A

instructions:

Resistance R1 ensures optimal accuracy of the sensor when the input current is at the rated primary current, therefore the sensor should measure the voltage corresponding to a primary current of 10mA as much as possible.

For example, measuring voltage VIN=250V

Accuracy=± 0.8% ofVIN (@ Ta=+25 ℃) a) R1=25K Ω/10W, IP=10mA

Accuracy=± 1.6% of VIN (@ Ta=+25 ℃) b) R1=50K Ω/5W, IP=5mA

The operating range (recommended) takes into account the resistance of the primary coil (which may be lower compared to R1 to maintain a close temperature difference) and isolation, making this sensor suitable for measuring voltage.

Main tolerances

  • Total tolerance ± 0.2mm
  • Pin 2 for connecting the primary coil, 0.8mm * 0.8mm
  • Pin 3 for connecting secondary coil 0.8mm * 0.8mm
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!