Brand automatic lid removal centrifuge
The brand's automatic lid removal centrifuge adopts electronic door locks, which have strong safety performance. The door cover is not closed properly
Product details

Brand automatic lid removal centrifugeThe performance characteristics are as follows:

At present, hospitals at all levels generally use vacuum blood collection tubes when collecting blood samples. After completing blood centrifugation, the tube cap must be manually removed, which is inefficient; The vibration generated by removing the cap may cause blood to re mix and increase the risk of bacterial infection. The CTK80 and CTK120 automatic cap removal centrifuges developed by Xiangyi can complete cap removal and centrifugation in one go, with a success rate of cap removal. Solved the problem of vacuum blood collection tube detachment that has plagued hospitals at all levels for many years, it is an ideal testing instrument for hospitals at all levels.

CTK80、CTK120Brand automatic lid removal centrifugecharacteristic:

-Automatic de capping of vacuum blood collection tubes, success rate of de capping

-Suitable for two lengths of 100mm and 75mm

-Touch panel, large screen LCD display, easy to operate

-Adopting AC variable frequency motor, with high speed control accuracy and fast speed up and down functions

-Automatically calculate RCF value

-Using special shock absorbers, the vibration reduction effect is good, and it has automatic balancing function

-Adopting electronic door locks, with strong safety performance. The door cover is not closed properly, and the centrifuge cannot be started; If the door cover opens abnormally during operation, it will automatically shut down

Adapter operation method:

The adapter is suitable for vacuum blood collection tubes of two lengths: 100mm and 75mm. When using a 100mm blood collection tube, all three layers of the middle plate need to be installed in place (left in Figure 2); When using a 75mm blood collection tube, first remove the upper plate, remove one layer of middle plate, only use two layers of middle plate, and then install the upper plate in place (Figure 2, right). If it is necessary to separate blood collection tubes of different lengths simultaneously, the number of adapter layers at symmetrical positions must be *, and the length and quantity of centrifuge tubes at symmetrical positions must be * (Figure 1). After centrifugation is completed, simply pick up the upper plate and the blood collection tube and cap will automatically separate (Figure 3, 4).

Technical parameters of CTK80 and CTK120 automatic de capping centrifuges:

Model CTK80 CTK120

Type Desktop Floor standing

Zui High Speed 4000 r/min 4000 r/min

The maximum relative centrifugal force is 3030 × g and 3370 × g, respectively

The largest number of separation is 80 (4 × 20) blood collection tubes and 120 (4 × 30) blood collection tubes

Display Type LCD Segmented LCD Display LCD Segmented LCD Display

Time control 1sec~99min59sec 1sec~99min59sec

Motor power AC variable frequency motor 600W AC variable frequency motor 700W

Power supply AC220V 50Hz 6A AC220V 50Hz 15A

Machine size

Length x Width x Height 470 x 560 x 380mm 580 x 800 x 900mm