The IPX3/4 pendulum tube rain test chamber produced by the Ritel test chamber manufacturer has the ability to simulate the heavy rain and rainstorm in the rain environment, which is mainly applicable to the test of the rain penetration resistance of the shells of electronic and electrical equipment, automobile parts and seals under the rain condition, or the working performance when or after the rain.
The "Degrees of Protection Provided by Enclosures (IP Code)" is equivalent to "IEC 60529:2001" GB 4208-2008
Environmental Durability of Road Vehicles and External Lighting and Light Signal Devices GB10485-2007
GB10485-2007 Basic Test Procedures for Manufacturing External Lighting of Automobiles and Trailers
Environmental Test Methods for Military Equipment - Rain Test (GJB 150.8-86)
※ Customization can be made according to customer requirements and different standards.
3、 Main technical parameters

| Model specifications | LX-500 | LX-800 | LX-010 | LX-015 | LX-020 | |||
| Internal dimensions | D(mm) | 800 | 800 | 1000 | 1000 | 1200 | ||
| W(mm) | 800 | 1000 | 1000 | 1500 | 1400 | |||
| H(mm) | 800 | 1000 | 1000 | 1000 | 1200 | |||
| volume | 500L | 800L | 1000L | 1500L | 2000L | |||
| temperature range | normal temperature | |||||||
| water pressure | 400Kpa | |||||||
| internet traffic | 0.6L/min±5% | |||||||
| Spray pipe diameter | Φ15mm | |||||||
| Test bench speed | 1~3r/min (adjustable) | |||||||
| Spray aperture | Φ0.8 mm | |||||||
| Spray aperture distance | 50mm | |||||||
| Swing tube swing angle amplitude | 180℃±20℃ | |||||||
| Swing tube adjustment | Infinite adjustment within approximately 60 ℃/S range | |||||||
| The above parameters meet the standards | GB10485-2007 | |||||||
| material | casing | Stainless steel plate SUS304 | ||||||
| endosome | Stainless steel plate SUS304 | |||||||
| regulator | heater | Nickel chromium alloy electric wire heater | ||||||
| fan | centrifugal fan | |||||||
| controller | monitor | Intelligent digital display controller, adopting PID self-tuning function, LED intuitive display, touch input method | ||||||
| Operation mode | Fixed value method | |||||||
| power supply | 1/N/PE AC220V±10% 50Hz | 3/N/PE AC380V±10% 50Hz | ||||||
| Standard configuration |
1 observation window, 1 set of sample rack, 1 lighting fixture, standard power cord (3 meters long), 4 casters |
|||||||
| timer |
Automatically stop when the device reaches the set running time, with a high degree of automation. |
|||||||
| Safety device |
Power overload, short circuit protection, phase loss protection, grounding protection, over temperature protection, water shortage protection, alarm sound prompt |
|||||||
| Conditions of Use |
1. Environmental conditions: |
|||||||
The above main technical indicators were measured at an ambient temperature of+25 ℃ without sample conditions.