Product details

Falling ball viscometer, Bole flying ball viscometer, Bole flying ball viscometer is an imported viscometer with a good reputation. It is used in conjunction with Brookfield constant temperature system to quickly control the temperature of the sample, thereby obtaining more accurate and highly reproducible results

measuring range 0.5-70,000mPa.S(cP)
material Ball 1 and Ball 2: borosilicate glass
Ball 3 and Ball 4: Nickel Iron Alloy
Ball 5 and Ball 6: Stainless Steel
Falling ball diameter 11.0mm-15.81mm
viscosity range 0.5-70000mpas(cP)
accuracy 0.5% -2.0% (depending on the choice of falling ball)
Measure the landing time of a falling ball 30-300 seconds**
Measurement interval length in the pipeline 100mm
Operating temperature range -5~+150℃
Sample tube volume 40ml
Viscometer size 180*220*330mm
**When the landing time of the falling ball in the measurement exceeds 300 seconds, fluid measurements with viscosity higher than 70000 mPa. s (cP) are allowed

Instrument composition: Instrument host, 6 ball drop kits, temperature probes, carrying case


  • Based on the Hoeppler measurement principle, simple and accurate dynamic viscosity measurements are performed on transparent Newtonian fluids. The core concept is to measure the actual time required for a falling ball to descend from a sample tube tilted at a working angle under the action of gravity.

  • The sample tube is assembled on a central bearing that allows the sample tube to quickly flip 180 degrees, allowing for immediate repeated measurements. The measurement results are based on the average time it takes for the falling ball to land in three measurements. Convert the time reading into the final viscosity value using another conversion formula

  • A set of six drop balls is used for various industrial QC controls and research institutions, and the easy-to-use and simple method of recording time measurements ensures meaningful test results.

  • Used in conjunction with the Brookfield constant temperature system to quickly control the temperature of the sample, resulting in more accurate and highly reproducible results

  • Model KF30 has a fixed angle of 80 degrees in accordance with DIN53015 standard; The Model KF40 can be set to 50, 60, 70, and 80 degrees to measure a wider range of viscosity

  • Meets the requirements of ASTM D53015 standard