Specification |
|
| Indicator Name |
Indicator requirements |
|
Working frequency range |
885~909MHz |
|
In band gain |
≥5dB |
|
Passband Ripple |
≤±0.5dB |
|
Output intermodulation |
≤-50dBc(-8dBm/ch/2ch) |
|
Filter stopband characteristics |
882.5MHz≤-50dB |
|
standing-wave ratio |
≤1.3 |
|
supply voltage |
+12VDC (introduced through a through-hole capacitor) |
|
lo leakage |
≤-45dBm |
|
Input and output impedance |
50 ohms |
|
Ambient Temperature |
-25℃~+55℃ |
|
Working environment humidity |
≤ 95% (non condensing) |
Band selector (930-954MHz):
| Specification | |
|
Indicator Name |
Indicator requirements |
|
Working frequency range |
930~954MHz |
|
In band gain |
≥5dB |
|
Passband Ripple |
≤±0.5dB |
|
Output intermodulation (minimum gain, maximum output) |
≤-50dBc(-8dBm/ch/2ch) |
|
Filter stopband characteristics |
927.5MHz≤-50dB |
|
standing-wave ratio |
≤1.3 |
|
supply voltage |
+12VDC (introduced through a through-hole capacitor) |
|
lo leakage |
≤-45dBm |
|
Input and output impedance |
50 ohms |
|
Ambient Temperature |
-25℃~+55℃ |
|
Working environment humidity |
≤ 95% (non condensing) |