1、 Product Introduction:

1. Temperature range: ambient temperature plus 15 ℃ to 200 ℃

2 APT.lineTMPreheating chamber technology

3. Controller using interval programming and real-time programming

4. 2 aluminum expansion brackets

5. Inert gas interface

6. Anti impact safety glass panel with spring plates

7. Independent adjustable temperature safety device level 2 (DIN 12880) with optical alarm

8. Computer interface: RS 422

9. Two switches output 24 V DC (maximum 0.4 A)

2、 Technical parameters:

PRODUCT MODEL VD115-230V1 VD115UL-120V1
Choose a model standard standard
Item code 9030-0031 9030-0037
measure
Internal volume [L] 115 115
Net weight of equipment (unloaded) [kg] 153 153
Maximum total load [kg] 65 65
Maximum load per partition [kg] 20 20
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 740 740
Net weight at height [mm] 900 900
Depth net weight [mm] 670 670
Wall to side distance [mm] 135 135
Wall distance from rear [mm] 100 100
Observation window width [mm] 456 456
Observation window height [mm] 413 413
Internal dimensions
Width [mm] 506 506
Height [mm] 506 506
Depth [mm] 460 460
The number of doors
Outer door 1 1
firmware
Number of partitions (hours/maximum) 2/6 2/6
Temperature performance data
The temperature range exceeds the indoor temperature by 15 ℃ to [℃] 200 200
Temperature deviation within 100 ℃ [± K] 3.5 3.5
Temperature fluctuation [± K] 0.1 0.1
Heating time to 100 ℃ [min] 95 95
Vacuum data
Allowable maximum vacuum [mbar] 0.01 0.01
Leakage rate [bar/h] 0.01 0.01
Electric data
Rated voltage [V] 230 120
Power frequency [Hz] 50/60 60
Rated power [kW] 1.7 1.7
Equipment safety device [A] 10 20
Phase (rated voltage) 1~ 1~
Connector
Vacuum interface with small flange [DN mm] 16 16
Test hole with small flange [DN mm] 16 16
Inert gas interface with flow restrictor (RP) 3/8 3/8

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. We reserve the right to make technical changes.