BINDER UFV500 ultra-low temperature refrigerator
1、 Product Introduction:
1. Temperature range: -40 ℃ to -86 ℃
2. Cooling through cascaded compression coolers
3. Fluorine free safe refrigerants R-404A and R-508B
4. Doors with right or left limiters
5. Access check via RFID (depending on model)
6. Data logger USB (depending on model)
7. Water cooling (depending on model)
8. Electric mechanical door lock
9. 4 compartment doors made of ABS plastic
10. Internal chamber made of stainless steel
11. Insulated by vacuum heat shield and polyurethane foam
12. Alarm system with backup battery
13. Computer interface: RS 422
14. Analog output 4-20 mA
15. Zero voltage alarm contact
16. Working hour timer
17. Three inserts made of stainless steel
2、 Technical parameters:
| Product Model |
UFV500-230V-R1 | UFV500-230V-L1 | UFV500-230V-RW1 | UFV500-230V-LW1 | Ufv50iul-120v-r1 | UFV500UL-120V-L1 |
Ufv500ul -240v-r1 |
UFV500UL -240V-L1 |
| Choose a model | Right door limiter, RFID system | Left door limiter, RFID system | Right door limiter, water-cooled, RFID system | Left door limiter, water-cooled, RFID system | Right door limiter, data logger USB | Left door limiter, data logger USB | Right door limiter, data logger USB | Left door limiter, data logger USB |
| Item code | 9020-0236 | 9020-0213 | 9020-0259 | 9020-0260 | 9020-0235 | 9020-0222 | 9020-0234 | 9020-0220 |
| measurement | ||||||||
| Internal volume [L] | 483 | 483 | 483 | 483 | 483 | 483 | 483 | 483 |
| Net weight of equipment (unloaded) [kg] | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 |
| Maximum total load [kg] | 200 | 200 | 200 | 200 | 200 | 200 | 200 | 200 |
| Maximum load per grid [kg] | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Maximum load per partition [kg] | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| The dimensions of the casing do not include additional components and connectors | ||||||||
| Net weight width [mm] | 830 | 830 | 830 | 830 | 830 | 830 | 830 | 830 |
| Net weight at height [mm] | 1985 | 1985 | 1985 | 1985 | 1985 | 1985 | 1985 | 1985 |
| Depth net weight [mm] | 885 | 885 | 885 | 885 | 885 | 885 | 885 | 885 |
| Wall distance from rear [mm] | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
| Wall to side distance [mm] | 175 | 175 | 175 | 175 | 175 | 175 | 175 | 175 |
| internal dimensions | ||||||||
| Width [mm] | 619 | 619 | 619 | 619 | 619 | 619 | 619 | 619 |
| Height [mm] | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 |
| Depth [mm] | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 |
| number of doors | ||||||||
| outer gate | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Data related to the environment | ||||||||
| Energy consumption at the set value of -80 ℃ and Tu=25 ℃ (+/-10%) [kWh/d] | 13.9 | 13.9 | 13.9 | 13.9 | 12.5 | 12.5 | 14.9 | 14.9 |
| Sound pressure level [dB (A)] | 49 | 49 | 49 | 49 | 49 | 49 | 49 | 49 |
| firmware | ||||||||
| Number of partitions (hours/maximum) | 3/7 | 3/7 | 3/7 | 3/7 | 3/7 | 3/7 | 3/7 | 3/7 |
| Load variation | ||||||||
| Refrigerator bracket for each compartment | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |
| Low temperature storage box 50mm | 352 | 352 | 352 | 352 | 352 | 352 | 352 | 352 |
| Temperature performance data | ||||||||
| Temperature range [℃] | -86…-40 | -86…-40 | -86…-40 | -86…-40 | -86…-40 | -86…-40 | -86…-40 | -86…-40 |
| Temperature deviation is -80 ℃ [± K] | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 |
| Cooling time from 25 ℃ to -80 ℃ [min] | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 |
| Heating time from -80 ℃ to -60 ℃ during power outage [min] | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 |
| Electrical data | ||||||||
| Rated voltage [V] | 230 | 230 | 230 | 230 | 120 | 120 | 208…240 | 208…240 |
| Power frequency [Hz] | 50 | 50 | 50 | 50 | 60 | 60 | 60 | 60 |
| Rated power [kW] | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 |
| Equipment safety device [A] | 10 | 10 | 10 | 10 | 16 | 16 | 10 | 10 |
| Phase (rated voltage) | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ |
1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. We reserve the right to make technical changes.