BINDER KBF115 Constant Temperature and Humidity Chamber
1、 Product Introduction:
1. Temperature range: 0 ℃ to 70 ℃
2. Humidity range: 10% relative humidity to 80% relative humidity
3 APT.lineTMPreheating chamber technology
4. Using capacitive humidity sensors and steam humidification for humidity regulation
5. Intuitive touch screen controller using interval programming and real-time programming
6. Internal data logger and open format measurement values can be read through USB
7. Equipment self-test is used for comprehensive status analysis
8. The sealed inner door is made of safety glass (ESG)
9. Prevent corrosion of glass through a special TIMELESS coating.
10. The interior is entirely made of stainless steel
11. A bracket made of stainless steel
12. Access hole with silicone plug 30mm, left
13. Independently adjustable temperature safety device Class 3.1 (DIN 12880), equipped with optical and acoustic temperature alarms
14. Computer interface: Ethernet
15. Door heating
2、 Technical parameters:
| PRODUCT MODEL | KBF115-230V1 | KBF115UL-240V1 |
| Choose a model | standard | standard |
| Item code | 9020-0320 | 9020-0321 |
| measure | ||
| Internal volume [L] | 102 | 102 |
| Net weight of equipment (unloaded) [kg] | 129 | 129 |
| Maximum total load [kg] | 100 | 100 |
| Maximum load per partition [kg] | 30 | 30 |
| The dimensions of the casing do not include additional components and connectors | ||
| Net weight width [mm] | 880 | 880 |
| Net weight at height [mm] | 1050 | 1050 |
| Depth net weight [mm] | 650 | 650 |
| Wall to side distance [mm] | 100 | 100 |
| Wall distance from rear [mm] | 100 | 100 |
| Internal dimensions | ||
| Width [mm] | 600 | 600 |
| Height [mm] | 483 | 483 |
| Depth [mm] | 351 | 351 |
| The number of doors | ||
| Inner door | 1 | 1 |
| Outer door | 1 | 1 |
| Data related to the environment | ||
| Energy consumption at 40 ℃ and 75% relative humidity [Wh/h] | 470 | 470 |
| Sound pressure level [dB (A)] | 52 | 52 |
| firmware | ||
| Number of partitions (hours/maximum) | 2/5 | 2/5 |
| Temperature performance data | ||
| Temperature range [℃] | 0…70 | 0…70 |
| Temperature deviation at 40 ℃ [± K] | 0.2 | 0.2 |
| Temperature fluctuation [± K] | 0.1 | 0.1 |
| The maximum thermal compensation is at 40 ℃ [W] | 200 | 200 |
| Climate performance data | ||
| Temperature range [℃] | 10…70 | 10…70 |
| Temperature deviation at 40 ℃ and 75% relative humidity [± K] | 0.2 | 0.2 |
| Temperature deviation at 25 ℃ and 60% relative humidity [± K] | 0.2 | 0.2 |
| Temperature fluctuation at 40 ℃ and 75% relative humidity [± K] | 0.1 | 0.1 |
| Temperature fluctuation at 25 ℃ and 60% relative humidity [± K] | 0.1 | 0.1 |
| Humidity range [% relative humidity] | 10…80 | 10…80 |
| Humidity fluctuation at 25 ℃ and 60% relative humidity | ≤ 2 ± relative humidity | ≤ 2 ± relative humidity |
| Humidity fluctuation at 40 ℃ and 75% relative humidity | ≤ 2 ± relative humidity | ≤ 2 ± relative humidity |
| The humidity recovery time after opening the door in 30 seconds is at 40 ℃ and 75% relative humidity [min] | 7 | 7 |
| The humidity recovery time after opening the door in 30 seconds is at 25 ℃ and 60% relative humidity [min] | 6 | 6 |
| Electric data | ||
| Rated voltage [V] | 200…230 | 200…240 |
| Power frequency [Hz] | 50/60 | 50/60 |
| Rated power [kW] | 2 | 2 |
| Equipment safety device [A] | 16 | 16 |
| Phase (rated voltage) | 1~ | 1~ |
1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.