BINDER BF720 Biochemical Incubator
1、 Product Introduction:
1. Temperature range: ambient temperature plus 10 ℃ to 300 ℃
2. Up to 30% more energy-efficient than common devices on the market
3. Utilizing APT.line ™ Technology achieves high temperature accuracy
4. Adjustable fan speed
5. Controller with LCD display and advanced time function
6. Exhaust valve electromechanical control
7. 2 chrome plated sockets
8. Integrated independently adjustable temperature safety device level 2 (DIN 12880) with optical alarm
9. Ergonomic handle design
10. Ethernet interface
11. USB interface for recording data
2、 Technical parameters:
| Product Model | BF720-230V1 | BF720UL-240V1 |
| Choose a model | standard | standard |
| Item code | 9010-0321 | 9010-0322 |
| measurement | ||
| Internal volume [L] | 734 | 734 |
| Net weight of equipment (unloaded) [kg] | 166 | 166 |
| Maximum total load [kg] | 315 | 315 |
| Maximum load per partition [kg] | 45 | 45 |
| The dimensions of the casing do not include additional components and connectors | ||
| Net weight width [mm] | 1165 | 1165 |
| Net weight at height [mm] | 1590 | 1590 |
| Depth net weight [mm] | 870 | 870 |
| Wall to side distance [mm] | 100 | 100 |
| Wall distance from rear [mm] | 160 | 160 |
| internal dimensions | ||
| Width [mm] | 1000 | 1000 |
| Height [mm] | 1300 | 1300 |
| Depth [mm] | 565 | 565 |
| number of doors | ||
| inner door | 2 | 2 |
| outer gate | 2 | 2 |
| Data related to the environment | ||
| Energy consumption at 37 ℃ [Wh/h] | 130 | 130 |
| Sound pressure level [dB (A)] | 43 | 43 |
| firmware | ||
| Number of partitions (hours/maximum) | 2/16 | 2/16 |
| Temperature performance data | ||
| The temperature range exceeds the indoor temperature by 10 ℃ to [℃] | 100 | 100 |
| The temperature deviation is 37 ℃ [± K] | 0.3 | 0.3 |
| Temperature fluctuation at 37 ℃ [± K] | 0.1 | 0.1 |
| Heating time to 37 ℃ [min] | 15 | 15 |
| The recovery time after opening the door in 30 seconds is 37 ℃ [min] | 4 | 4 |
| Electrical data | ||
| Rated voltage [V] | 230 | 240 |
| Power frequency [Hz] | 50/60 | 60 |
| Rated power [kW] | 1.75 | 1.85 |
| Phase (rated voltage) | 1~ | 1~ |
1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. We reserve the right to make technical changes.