English

Shanghai Huanao Technology Co., Ltd
Home>Products>BINDER BF720 Biochemical Incubator
BINDER BF720 Biochemical Incubator
BINDER BF720 Biochemical Incubator
Product details

BINDER BF720 Biochemical Incubator

1、 Product Introduction:

1. Temperature range: ambient temperature plus 10 ℃ to 300 ℃

2. Up to 30% more energy-efficient than common devices on the market

3. Utilizing APT.line ™ Technology achieves high temperature accuracy

4. Adjustable fan speed

5. Controller with LCD display and advanced time function

6. Exhaust valve electromechanical control

7. 2 chrome plated sockets

8. Integrated independently adjustable temperature safety device level 2 (DIN 12880) with optical alarm

9. Ergonomic handle design

10. Ethernet interface

11. USB interface for recording data

2、 Technical parameters:

Product Model BF720-230V1 BF720UL-240V1
Choose a model standard standard
Item code 9010-0321 9010-0322
measurement
Internal volume [L] 734 734
Net weight of equipment (unloaded) [kg] 166 166
Maximum total load [kg] 315 315
Maximum load per partition [kg] 45 45
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 1165 1165
Net weight at height [mm] 1590 1590
Depth net weight [mm] 870 870
Wall to side distance [mm] 100 100
Wall distance from rear [mm] 160 160
internal dimensions
Width [mm] 1000 1000
Height [mm] 1300 1300
Depth [mm] 565 565
number of doors
inner door 2 2
outer gate 2 2
Data related to the environment
Energy consumption at 37 ℃ [Wh/h] 130 130
Sound pressure level [dB (A)] 43 43
firmware
Number of partitions (hours/maximum) 2/16 2/16
Temperature performance data
The temperature range exceeds the indoor temperature by 10 ℃ to [℃] 100 100
The temperature deviation is 37 ℃ [± K] 0.3 0.3
Temperature fluctuation at 37 ℃ [± K] 0.1 0.1
Heating time to 37 ℃ [min] 15 15
The recovery time after opening the door in 30 seconds is 37 ℃ [min] 4 4
Electrical data
Rated voltage [V] 230 240
Power frequency [Hz] 50/60 60
Rated power [kW] 1.75 1.85
Phase (rated voltage) 1~ 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. We reserve the right to make technical changes.